共 23 条
Study of the effect of stenosis severity and non-Newtonian viscosity on multidirectional wall shear stress and flow disturbances in the carotid artery using particle image velocimetry
被引:26
|作者:
DiCarlo, Amanda L.
[1
]
Holdsworth, David W.
[2
,3
,4
,5
]
Poepping, Tamie L.
[1
,2
]
机构:
[1] Univ Western Ontario, Dept Phys & Astron, 1151 Richmond St, London, ON N6A 3K7, Canada
[2] Univ Western Ontario, Dept Med Biophys, 1151 Richmond St, London, ON N6A 5C1, Canada
[3] Univ Western Ontario, Dept Surg, 268 Grosvenor St, London, ON N6A 4V2, Canada
[4] Univ Western Ontario, Robarts Res Inst, 1151 Richmond St, London, ON N6A 5B7, Canada
[5] Univ Western Ontario, Bone & Joint Inst, 1151 Richmond St, London, ON N6G 2V4, Canada
基金:
加拿大健康研究院;
加拿大自然科学与工程研究理事会;
加拿大创新基金会;
关键词:
Non-Newtonian fluid;
Atherosclerosis;
Stenosis severity;
Carotid bifurcation;
Wall shear stress;
Oscillatory shear index;
Transverse wall shear stress;
Turbulence intensity;
Stereoscopic particle image velocimetry;
Shear-thinning;
Blood analogue fluid;
RIGHT CORONARY-ARTERIES;
BLOOD-FLOW;
IN-VIVO;
PULSATILE FLOW;
HEMORHEOLOGICAL CHANGES;
TURBULENCE INTENSITY;
NUMERICAL-SIMULATION;
BIFURCATION MODEL;
HELICAL FLOW;
PLAQUE;
D O I:
10.1016/j.medengphy.2018.12.023
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
The development of atherosclerosis at the carotid bifurcation is impacted by local variations in wall shear stress (WSS) magnitude and direction, as well as flow complexity within the vessel. In this study, stereoscopic particle image velocimetry (PIV) was used to investigate multidirectional WSS and disturbed flow for idealized models of the carotid bifurcation with varying eccentric stenosis of the internal carotid artery (ICA) and both Newtonian (N-fluid) and non-Newtonian (nN-fluid) blood analogues. Turbulence intensity (TI) was reduced with the nN-fluid compared to N-fluid for mild to moderate stenosis, and comparable for more severely stenosed (70%) models. Differences in maximum TI due to viscosity model ranged from 0.02 m/s to 0.06 m/s compared to much larger differences due to geometry of up to 0.29 m/s between mild and severe stenosis. The level of time-averaged WSS (TAWSS) increased with stenosis severity from 5 Pa to 32 Pa, and nN-fluid led to higher WSS on average than N-fluid counterparts. Regions of elevated oscillatory shear index (OSI) demarcated recirculation regions, and mean OSI in the ICA branch was reduced for nN-fluid models by 9-19% compared to N-fluid. Transverse WSS (transWSS) increased with WSS magnitude and again was higher in nN-fluid models. Surface area exposure to shear metrics indicated that a Newtonian viscosity assumption predicted larger regions of low and oscillatory WSS, while predicting reduced regions of high transWSS, in comparison to the more physiological shear thinning fluid. Crown Copyright (C) 2019 Published by Elsevier Ltd on behalf of IPEM. All rights reserved.
引用
收藏
页码:8 / 23
页数:16
相关论文