Segmental limited-angle CT reconstruction based on image structural prior

被引:4
|
作者
Gong, Changcheng [1 ,3 ]
Shen, Zhaoqiang [2 ]
He, Yuanwei [2 ]
机构
[1] Chongqing Technol & Business Univ, Sch Math & Stat, Chongqing 400067, Peoples R China
[2] Chongqing Univ, Coll Math & Stat, Chongqing, Peoples R China
[3] Chongqing Technol & Business Univ, Chongqing Key Lab Social Econ & Appl Stat, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Inverse problems; computed tomography; relative total variation; image sparsity; iterative reconstruction; L(0);
D O I
10.3233/XST-221222
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CT reconstruction from incomplete projection data is one of the key researches of X-ray CT imaging. The projection data acquired by few-view and limited-angle sampling are incomplete. In addition, few-view sampling often requires turning on and off the tube voltage, but rapid switching of tube voltage demands for high technical requirements. Limited-angle sampling is easy to realize. However, reconstructed images may encounter obvious artifacts. In this study we investigate a new segmental limited-angle (SLA) sampling strategy, which avoids rapid switching of tube voltage. Thus, the projection data has lower data correlation than limited-angle CT, which is conducive to reconstructing high-quality images. To suppress potential artifacts, we incorporate image structural prior into reconstruction model to present a reconstruction method. The limited-angle CT reconstruction experiments on digital phantoms, real carved cheese and walnut projections are used to test and verify the effectiveness of the proposed method. Several image quality evaluation indices including RMSE, PSNR, and SSIM of the reconstructions in simulation experiments are calculated and listed to show the superiority of our method. The experimental results indicate that the CT image reconstructed using the proposed new method is closer to the reference image. Images from real CT data and their residual images also show that applying the proposed new method can more effectively reduce artifacts and image structures are well preserved.
引用
收藏
页码:1127 / 1154
页数:28
相关论文
共 50 条
  • [21] Image reconstruction method for limited-angle CT based on total variation minimization using guided image filtering
    Jiaxi Wang
    Yuanyuan Yue
    Chengxiang Wang
    Wei Yu
    Medical & Biological Engineering & Computing, 2022, 60 : 2109 - 2118
  • [22] A limited-angle CT reconstruction method based on anisotropic TV minimization
    Chen, Zhiqiang
    Jin, Xin
    Li, Liang
    Wang, Ge
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2119 - 2141
  • [23] Image reconstruction method for limited-angle CT based on total variation minimization using guided image filtering
    Wang, Jiaxi
    Yue, Yuanyuan
    Wang, Chengxiang
    Yu, Wei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (07) : 2109 - 2118
  • [24] Guided image filtering based l0 gradient minimization for limited-angle CT image reconstruction
    Wang, Tianyi
    Wang, Chengxiang
    Zhao, Kequan
    Yu, Wei
    Huang, Min
    JOURNAL OF INVERSE AND ILL-POSED PROBLEMS, 2021, 29 (04): : 587 - 598
  • [25] Curvature constraint based image reconstruction for limited-angle computed tomography
    Xue, Xiao
    Zhao, Shusen
    Zhao, Yunsong
    Zhang, Peng
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [26] Anisotropic Total Variation for Limited-angle CT Reconstruction
    Jin, Xin
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2232 - 2238
  • [27] IMAGE-RECONSTRUCTION FROM LIMITED-ANGLE PROJECTIONS
    BABA, N
    MURATA, K
    OPTIK, 1982, 60 (03): : 327 - 332
  • [28] Image Reconstruction from limited-angle range projections
    Du, Nan
    Feng, Yusheng
    Grigoryan, Artyom M.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [29] Limited-Angle CT Image Reconstruction Based on Swin-Transformer Iterative Unfolding for PTCT Imaging
    Yuan Wei
    Xi Yarui
    Tan Chuandong
    Liu Chuanjiang
    Zhu Guorong
    Liu Fenglin
    ACTA OPTICA SINICA, 2024, 44 (08)
  • [30] ENHANCING IMAGE QUALITY IN LIMITED-ANGLE CT RECONSTRUCTION FOR REACTOR PRESSURE PIPELINES DETECTION
    Fu, Jintao
    Chang, Jiahao
    Sun, Yuewen
    Zeng, Tianchen
    Tang, Peng
    Xu, Shuo
    Cong, Peng
    PROCEEDINGS OF 2024 31ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 11, ICONE31 2024, 2024,