Exergetic Analysis of a Novel Solar Cooling System for Combined Cycle Power Plants

被引:8
|
作者
Calise, Francesco [1 ]
Libertini, Luigi [1 ]
Vicidomini, Maria [1 ]
机构
[1] Univ Naples Federico II, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
关键词
solar cooling; combined cycle; absorption chiller; exergetic analysis; RENEWABLE POLYGENERATION SYSTEM; OXIDE FUEL-CELL; DIRECT STEAM-GENERATION; DYNAMIC SIMULATION; THERMOECONOMIC OPTIMIZATION; PERFORMANCE IMPROVEMENT; EXERGOECONOMIC ANALYSIS; ENVIRONMENTAL-ANALYSES; HEAT-TRANSFER; GAS-TURBINES;
D O I
10.3390/e18100356
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This paper presents a detailed exergetic analysis of a novel high-temperature Solar Assisted Combined Cycle (SACC) power plant. The system includes a solar field consisting of innovative high-temperature flat plate evacuated solar thermal collectors, a double stage LiBr-H2O absorption chiller, pumps, heat exchangers, storage tanks, mixers, diverters, controllers and a simple single-pressure Combined Cycle (CC) power plant. Here, a high temperature solar cooling system is coupled with a conventional combined cycle, in order to pre-cool gas turbine inlet air in order to enhance system efficiency and electrical capacity. In this paper, the system is analyzed from an exergetic point of view, on the basis of an energy-economic model presented in a recent work, where the obtained main results show that SACC exhibits a higher electrical production and efficiency with respect to the conventional CC. The system performance is evaluated by a dynamic simulation, where detailed simulation models are implemented for all the components included in the system. In addition, for all the components and for the system as whole, energy and exergy balances are implemented in order to calculate the magnitude of the irreversibilities within the system. In fact, exergy analysis is used in order to assess: exergy destructions and exergetic efficiencies. Such parameters are used in order to evaluate the magnitude of the irreversibilities in the system and to identify the sources of such irreversibilities. Exergetic efficiencies and exergy destructions are dynamically calculated for the 1-year operation of the system. Similarly, exergetic results are also integrated on weekly and yearly bases in order to evaluate the corresponding irreversibilities. The results showed that the components of the Joule cycle (combustor, turbine and compressor) are the major sources of irreversibilities. System overall exergetic efficiency was around 48%. Average weekly solar collector exergetic efficiency ranged from 6.5% to 14.5%, significantly increasing during the summer season. Conversely, absorption chiller exergy efficiency varies from 7.7% to 20.2%, being higher during the winter season. Combustor exergy efficiency is stably close to 68%, whereas the exergy efficiencies of the remaining components are higher than 80%.
引用
收藏
页数:31
相关论文
共 50 条
  • [21] Exergy analysis of a solar combined cycle: organic Rankine cycle and absorption cooling system
    Grosu, Lavinia
    Marin, Andreea
    Dobrovicescu, Alexandru
    Queiros-Conde, Diogo
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 7 (04) : 449 - 459
  • [22] Energy efficiency and exergetic analysis of combined cycle plant with inlet air cooling
    Padhi B.N.
    Pattanayak L.
    International Journal of Ambient Energy, 2023, 44 (01) : 2433 - 2445
  • [23] Exergetic analysis of an integrated power production solar system
    Koroneos, Christopher J.
    Rovas, Dirnitrios C.
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 1517 - +
  • [24] Comparative Exergetic Analysis of Solar Integration and Regeneration in Steam Power Plants
    Iodice, Paolo
    Langella, Giuseppe
    Amoresano, Amedeo
    Senatore, Adolfo
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (05)
  • [25] Analysis of experimental power and cooling production in a combined power and cooling cycle
    Martin, CL
    Goswami, AY
    Energy-Efficient, Cost-Effective and Environmentally-Sustainable Systems and Processes, Vols 1-3, 2004, : 1235 - 1243
  • [26] Comparison of carbon capture system and concentrated solar power in natural gas combined cycle: Exergetic and exergoenvironmental analyses
    Cavalcanti, Eduardo J. C.
    Lima, Matheus S. R.
    de Souza, Gabriel F.
    RENEWABLE ENERGY, 2020, 156 (156) : 1336 - 1347
  • [27] EXERGETIC ANALYSIS OF COMBINED CYCLE POWER PLANT WITH SINGLE STEAM EXTRACTION
    Dev, Nikhil
    Goyal, Gopal Krishan
    Attri, Rajesh
    Kumar, Naresh
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2013, 2014,
  • [28] Exergetic and economic evaluation of the effect of HRSG configurations on the performance of combined cycle power plants
    Mansouri, Mohammad Tajik
    Ahmadi, Pouria
    Kaviri, Abdolsaeid Ganjeh
    Jaafar, Mohammad Nazri Mohd
    ENERGY CONVERSION AND MANAGEMENT, 2012, 58 : 47 - 58
  • [29] Analysis of A Solar Assisted Combined Cooling, Heating and Power (SCCHP) System
    Zhang, Na
    Wang, Zefeng
    Han, Wei
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 55 - 62
  • [30] Exergy analysis of a combined power and cooling cycle
    Fontalvo, Armando
    Pinzon, Horacio
    Duarte, Jorge
    Bula, Antonio
    Gonzalez Quiroga, Arturo
    Vasquez Padilla, Ricardo
    APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) : 164 - 171