Greater saphenous vein evaluation from computed tomography angiography as a potential alternative to conventional ultrasonography

被引:7
|
作者
Johnston, William F. [1 ]
West, Jonathan K. [2 ]
LaPar, Damien J. [3 ]
Cherry, Kenneth J. [1 ]
Kern, John A. [1 ]
Tracci, Margaret C. [1 ]
Ailawadi, Gorav [3 ]
Upchurch, Gilbert R., Jr. [1 ]
机构
[1] Univ Virginia, Div Vasc & Endovasc Surg, Charlottesville, VA USA
[2] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA USA
[3] Univ Virginia, Div Cardiothorac Surg, Charlottesville, VA USA
关键词
CT PULMONARY ANGIOGRAPHY; BYPASS; VENOGRAPHY; ULTRASOUND;
D O I
10.1016/j.jvs.2012.04.055
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Autologous greater saphenous vein (GSV) graft is frequently used as a conduit during arterial bypass. Preoperative vein mapping has been traditionally used to assess conduit adequacy and define GSV anatomy, thereby decreasing operative time and reducing wound complications. The purpose of this study was to determine whether GSV mapping using computed tomography angiography (CTA) closely correlated with that of traditional duplex ultrasonography (US). Methods: From August 2009 through June 2011, 88 limbs from 51 patients underwent CTA of the lower extremities for the purpose of defining arterial anatomy with concurrent US for preoperative vein mapping. GSV diameters were measured by two blinded reviewers on CTA (both antero-posterior [AP] and lateral dimensions) and compared with US-based measurements at levels of the proximal thigh, mid-thigh, knee, mid-calf, and ankle. CTA and US measurements were compared at each anatomic level using linear regression. Statistical analysis was performed using SPSS software. Charge reduction was calculated based on technical and professional fees for each imaging study. Results: GSV diameter sequentially decreased from the proximal thigh to the mid-calf and then increased to the ankle as measured by CTA and US. CTA-based measurements of the GSV significantly correlated with US GSV diameters (R = 0.927 [lateral dimension], 0.922 [AP dimension]; P < .005). The strongest degree of correlation occurred in measurements at the proximal thigh, followed by the mid-thigh, mid-calf, knee, and ankle. GSV measurement by CTA was over 90% sensitive and accurate for detecting appropriate GSV diameter for bypass (diameter >2.0 mm). Eliminating preoperative US vein mapping for the study patients at our institution would have resulted in charge reductions of $49,316 over the study period. Conclusions: Indirect venography by CTA correlates well with US for GSV mapping in the lower extremity and offers significant reduction in imaging-related preoperative charges. CTA is sensitive and accurate for detecting GSVs that are appropriate for bypass. Furthermore, CTA allows AP and lateral evaluation of the GSV throughout its anatomic course. As CTA is often performed prior to arterial bypass, indirect evaluation of the GSV using preoperative CTA should be considered a promising alternative to the use of US. (J Vasc Surg 2012;56:1331-7.)
引用
收藏
页码:1331 / U157
页数:8
相关论文
共 50 条
  • [41] COMPARISON OF RADIATION INDUCED DAMAGE BETWEEN COMPUTED TOMOGRAPHY ANGIOGRAPHY AND CONVENTIONAL CORONARY ANGIOGRAPHY
    Sahinarslan, A.
    Erbas, G.
    Baser, D.
    Akyel, A.
    Kocaman, S.
    Karer, D.
    Yuce, C.
    Ergun, M. A.
    Arac, M.
    Boyaci, B.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S60 - S60
  • [42] Comparison of radiation induced damage between computed tomography angiography and conventional coronary angiography
    Sahinarslan, A.
    Erbas, G.
    Kocaman, S.
    Baser, D.
    Akyel, A.
    Karaer, D.
    Yuce, C.
    Ergun, M. A.
    Arac, M.
    Boyaci, B.
    EUROPEAN HEART JOURNAL, 2011, 32 : 522 - 522
  • [43] A comparative study of low voltage, low contrast cerebral computed tomography angiography with iterative reconstruction and conventional cerebral computed tomography angiography
    Mishra, Saurav
    Mishra, Sandeep
    Regmi, Sabina
    Gupta, Vivek
    NEURORADIOLOGY JOURNAL, 2024, 37 (02): : 221 - 228
  • [44] Re: Evaluation of Potential Renal Transplant Recipients with Computed Tomography Angiography Editorial Comment
    Goldfarb, David A.
    JOURNAL OF UROLOGY, 2014, 191 (02): : 425 - 425
  • [45] Dynamic Volumetric Computed Tomography Angiography Is a Preferred Method for Unclassified Endoleaks by Conventional Computed Tomography Angiography After Endovascular Aortic Repair
    Hou, Kai
    Zhu, Ting
    Zhang, Wei
    Zeng, Mengsu
    Guo, Daqiao
    Fu, Weiguo
    Si, Yi
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (08):
  • [46] Evaluation of coronary artery stent patency by using 64-slice multi-detector computed tomography and conventional coronary angiography: A comparison with intravascular ultrasonography
    Hang, Chi-Ling
    Lee, Yi-Wei
    Guo, Gary Bih-Fang
    Youssef, Ali Ahmed
    Yip, Hon-Kan
    Liu, Chu-Feng
    Chua, Sarah
    Chang, Hseuh-Wen
    Cheng, Yu-Fan
    Chen, Shyh-Ming
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (01) : 90 - 95
  • [47] Prevalence of portal vein thrombosis detected by computed tomography angiography in dogs
    von Stade, L. E.
    Shropshire, S. B.
    Rao, S.
    Twedt, D.
    Marolf, A. J.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2021, 62 (07) : 562 - 569
  • [48] “Pulmonary Vein Sign” for Pulmonary Embolism Diagnosis in Computed Tomography Angiography
    Luciana Volpon Soares Souza
    Matheus Zanon
    Arthur Soares Souza
    Klaus Irion
    Diana Penha
    Giordano Rafael Tronco Alves
    Edson Marchiori
    Bruno Hochhegger
    Lung, 2017, 195 : 769 - 774
  • [49] "Pulmonary Vein Sign" for Pulmonary Embolism Diagnosis in Computed Tomography Angiography
    Soares Souza, Luciana Volpon
    Zanon, Matheus
    Souza, Arthur Soares
    Irion, Klaus
    Penha, Diana
    Tronco Alves, Giordano Rafael
    Marchiori, Edson
    Hochhegger, Bruno
    LUNG, 2017, 195 (06) : 769 - 774
  • [50] Computed tomography angiography demonstration of portal vein anomaly type V
    Balaji, MCR
    Kalita, AJ
    Ravindranath, K
    Mathai, V
    Sreekanth, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (03) : 348 - 350