Greater saphenous vein evaluation from computed tomography angiography as a potential alternative to conventional ultrasonography

被引:7
|
作者
Johnston, William F. [1 ]
West, Jonathan K. [2 ]
LaPar, Damien J. [3 ]
Cherry, Kenneth J. [1 ]
Kern, John A. [1 ]
Tracci, Margaret C. [1 ]
Ailawadi, Gorav [3 ]
Upchurch, Gilbert R., Jr. [1 ]
机构
[1] Univ Virginia, Div Vasc & Endovasc Surg, Charlottesville, VA USA
[2] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA USA
[3] Univ Virginia, Div Cardiothorac Surg, Charlottesville, VA USA
关键词
CT PULMONARY ANGIOGRAPHY; BYPASS; VENOGRAPHY; ULTRASOUND;
D O I
10.1016/j.jvs.2012.04.055
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Autologous greater saphenous vein (GSV) graft is frequently used as a conduit during arterial bypass. Preoperative vein mapping has been traditionally used to assess conduit adequacy and define GSV anatomy, thereby decreasing operative time and reducing wound complications. The purpose of this study was to determine whether GSV mapping using computed tomography angiography (CTA) closely correlated with that of traditional duplex ultrasonography (US). Methods: From August 2009 through June 2011, 88 limbs from 51 patients underwent CTA of the lower extremities for the purpose of defining arterial anatomy with concurrent US for preoperative vein mapping. GSV diameters were measured by two blinded reviewers on CTA (both antero-posterior [AP] and lateral dimensions) and compared with US-based measurements at levels of the proximal thigh, mid-thigh, knee, mid-calf, and ankle. CTA and US measurements were compared at each anatomic level using linear regression. Statistical analysis was performed using SPSS software. Charge reduction was calculated based on technical and professional fees for each imaging study. Results: GSV diameter sequentially decreased from the proximal thigh to the mid-calf and then increased to the ankle as measured by CTA and US. CTA-based measurements of the GSV significantly correlated with US GSV diameters (R = 0.927 [lateral dimension], 0.922 [AP dimension]; P < .005). The strongest degree of correlation occurred in measurements at the proximal thigh, followed by the mid-thigh, mid-calf, knee, and ankle. GSV measurement by CTA was over 90% sensitive and accurate for detecting appropriate GSV diameter for bypass (diameter >2.0 mm). Eliminating preoperative US vein mapping for the study patients at our institution would have resulted in charge reductions of $49,316 over the study period. Conclusions: Indirect venography by CTA correlates well with US for GSV mapping in the lower extremity and offers significant reduction in imaging-related preoperative charges. CTA is sensitive and accurate for detecting GSVs that are appropriate for bypass. Furthermore, CTA allows AP and lateral evaluation of the GSV throughout its anatomic course. As CTA is often performed prior to arterial bypass, indirect evaluation of the GSV using preoperative CTA should be considered a promising alternative to the use of US. (J Vasc Surg 2012;56:1331-7.)
引用
收藏
页码:1331 / U157
页数:8
相关论文
共 50 条
  • [1] Greater Saphenous Vein Assessment Using Computed Tomographic Angiography
    Kempe, Kelly
    Harkrider, William
    Gonzalez, Arturo D.
    Comeaux, Michel E.
    JOURNAL OF VASCULAR SURGERY, 2011, 53 : 72S - 72S
  • [2] Computed tomography angiography-based evaluation of great saphenous vein conduit for lower extremity bypass
    deFreitas, Dorian J.
    Love, Timothy P.
    Kasirajan, Karthikeshwar
    Haskins, Noel C.
    Mixon, Ronald T.
    Brewster, Luke P.
    Duwayri, Yazan
    Corriere, Matthew A.
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 50 - 55
  • [3] Computed tomography arteriography to assess greater saphenous vein as a conduit for peripheral bypass
    Kang, Alan
    Buckenham, Timothy
    Roake, Justin
    Lewis, David
    ANZ JOURNAL OF SURGERY, 2007, 77 (10) : 870 - 872
  • [4] Computed tomography angiography-based evaluation of great saphenous vein conduit for lower extremity bypass DISCUSSION
    Ali, Ahsan T.
    deFreitas, Dorian J.
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (01) : 55 - 55
  • [5] Computed Tomography Angiography in the Assessment of Great Saphenous Vein as Conduit for Infrainguinal Bypass Surgery
    Belvedere, Shane
    Gouil, Quentin
    Thompson, Corey
    Solomon, Jarryd
    VASCULAR AND ENDOVASCULAR SURGERY, 2020, 54 (04) : 313 - 318
  • [6] Vascular invasion in pancreatic cancer:: evaluation of endoscopic ultrasonography, computed tomography, ultrasonography, and angiography
    Buchs, N. C.
    Frossard, J.
    Rosset, A.
    Chilcott, M.
    Koutny-Fong, P.
    Chassot, G.
    Fasel, J. H.
    Poletti, P. A.
    Becker, C. D.
    Mentha, G.
    Buehler, L.
    Morel, P.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 764 - 764
  • [7] Vascular invasion in pancreatic cancer - Evaluation of endoscopic ultrasonography, computed tomography, ultrasonography, and angiography
    Buchs, N. C.
    Frossard, J. L.
    Rosset, A.
    Chilcott, M.
    Koutny-Fong, P.
    Chassot, G.
    Fasel, J. H. D.
    Poletti, P. A.
    Becker, C. D.
    Mentha, G.
    Biihler, L.
    Morel, P.
    SWISS MEDICAL WEEKLY, 2007, 137 (19-20) : 286 - 291
  • [8] Computed tomography angiography-guided recanalization of saphenous vein graft chronic total occlusion
    Hajek, Petr
    Adla, Theodor
    Taborska, Katerina
    Veselka, Josef
    ARCHIVES OF MEDICAL SCIENCE, 2011, 7 (04) : 732 - 735
  • [9] Preoperative evaluation of the saphenous vein by 3-D contrastless computed tomography
    Maruyama, Yuji
    Imura, Hajime
    Shirakawa, Makoto
    Ochi, Masami
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (04) : 550 - 552
  • [10] Multidetector computed tomography of a saphenous vein graft aneurysm
    Sato, Y
    Ichikawa, M
    Nakanishi, K
    Matsumoto, N
    Yoda, S
    Kasamaki, Y
    Takayama, T
    Koyama, Y
    Inoue, F
    Takahashi, M
    Uchiyama, T
    Saito, S
    HEART AND VESSELS, 2006, 21 (02) : 135 - 136