Neutronic analysis of the ITER Equatorial Port Plug 1

被引:7
|
作者
Moro, F. [1 ]
Esposito, B. [1 ]
Brolatti, G. [1 ]
Marocco, D. [1 ]
Villari, R. [1 ]
Salasca, S. [2 ]
Cantone, B. [2 ]
Dapena-Febrer, M. [2 ]
Petrizzi, L. [3 ]
机构
[1] Assoc EURATOM ENEA Fus ENEA CR Frascati, I-00044 Rome, Italy
[2] IRFM, CEA, F-13108 St Paul Les Durance, France
[3] OECD Nucl Energy Agcy, F-92130 Issy Les Moulineaux, France
关键词
ITER; Neutronics; Equatorial Port Plug; Design; Analysis;
D O I
10.1016/j.fusengdes.2012.02.111
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER Equatorial Port 1 will host the following diagnostic systems: the Radial Neutron Camera (RNC), the High Resolution Neutron Spectrometer (HRNS), the Gamma Ray Spectrometer, the Hard X-Rays Monitor, the Pressure Gauges, the Bolometers, the Equatorial Visible/Infrared Wide Angle Viewing System (WAVS), the Neutron Flux Monitor (NFM), the Motional Stark Effect (MSE) system and the Divertor Impurity Monitor (DIM). These diagnostics are integrated inside the Port Plug, a water-cooled stainless steel support structure, which also includes Diagnostic Shielding Modules, designed to provide enough radiation shielding capabilities, to protect the diagnostic systems and to reduce the dose level in the Port Interspace. A new concept for the design of the Port Plug is under consideration: it is based on the installation of the diagnostics inside vertical drawers, completely independent from each other, that are inserted in the Port Plug structure through guiding rails. The paper presents the results of three-dimensional neutronic analyses performed with MCNP5 Monte Carlo code in support of the Port Plug design and integration. The reference ITER MCNP 40 degrees model "Alite" has been updated including the details of the drawers and three diagnostics. Nuclear heating radial profiles have been produced for different toroidal and poloidal positions to be used as input for thermal and thermo-mechanical analyses. 3-D Neutron flux maps have been calculated in order to assess the effect of radiation streaming through all gaps (between the drawers, around the Port Plug and along the diagnostic penetrations) and to provide an estimate of the shielding effectiveness of the new Port Plug concept. (C) 2012 EURATOM ENEA Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1224 / 1229
页数:6
相关论文
共 50 条
  • [21] ITER DIAGNOSTIC PORT PLUG DESIGN
    Balshaw, N. H.
    Krivchenkov, Y.
    Phillips, G.
    Davis, S.
    Pampin-Garcia, R.
    FUSION SCIENCE AND TECHNOLOGY, 2009, 56 (02) : 661 - 665
  • [22] Nuclear analysis of ITER Test Blanket Module Port Plug
    Villari, Rosaria
    Kim, Byoung Yoon
    Barabash, Vladimir
    Giancarli, Luciano
    Levesy, Bruno
    Loughlin, Michael
    Merola, Mario
    Moro, Fabio
    Pascal, Romain
    Petrizzi, Luigino
    Polunovsky, Eduard
    Van der Laan, Jaap G.
    FUSION ENGINEERING AND DESIGN, 2015, 98-99 : 1668 - 1673
  • [23] Neutronic effects of diagnostic shield module length on radiation environment of ITER diagnostic generic upper port plug
    Serikov, Arkady
    Bertalot, Luciano
    Fischer, Ulrich
    Juarez, Rafael
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 920 - 924
  • [24] Optimization of the Integrated Diagnostics in Equatorial Port Plug #3 of ITER for Minimal Interspace Dose Rate
    Youssef, Mahmoud Z.
    Feder, Russell E.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (05) : 1413 - 1420
  • [25] ITER diagnostic port plug engineering design analysis in the EU
    Ciattaglia, E.
    Ingesson, L. C.
    Campbell, D.
    Saibene, G.
    Walker, C.
    Doceu, L.
    Dirken, P.
    Petrizzi, L.
    Heidinger, R.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 1231 - 1237
  • [26] Design and Analysis Progress of ITER Diagnostic Equatorial Port #09
    Zhai, Yuhu
    Basile, Allan
    Feder, R.
    Wang, W.
    Chen, Jingping
    Khodak, Andrei
    Klabacha, Jonathan Paul
    Johnson, D.
    Hause, M.
    Messineo, M.
    Zhang, Han
    Gonzalez-Teodoro, Jorge Rafael
    Guirao, Julio
    Iglesias, Silvia
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (05) : 1254 - 1261
  • [27] EM Loads on ITER Diagnostics Equatorial Port Plug 9 and Its In-Port Components During Plasma Disruptions
    Chen, Jingping
    Zhai, Yuhu
    Feder, Russell
    FUSION SCIENCE AND TECHNOLOGY, 2017, 72 (04) : 686 - 691
  • [28] Neutronic analysis for bolometers in ITER
    Suarez, A.
    Reichle, R.
    Loughlin, M.
    Polunovskiy, E.
    Walsh, M.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1395 - 1399
  • [29] Engineering studies for integration of the test blanket module (TBM) systems inside an ITER equatorial port plug
    Madeleine, S.
    Saille, A.
    Martins, J. -R
    Salavy, J. -F.
    Jonqueres, N.
    Rampal, G.
    Bede, O.
    Neuberger, H.
    Boccaccini, L.
    Doceul, L.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1233 - 1237
  • [30] Assessment of shutdown dose rates in the ITER Collective Thomson Scattering system and in equatorial port plug 12
    Chambon, A.
    Luis, R.
    Klinkby, E.
    Nietiadi, Y.
    Rechena, D.
    Goncalves, B.
    Jessen, M.
    Korsholm, S. B.
    Larsen, A. W.
    Lauritzen, B.
    Rasmussen, J.
    Salewski, M.
    Fabbri, M.
    Morillo, C.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):