Calibration of motorized object rig and its applications

被引:0
|
作者
Huang, Pang-Hung [1 ,2 ]
Tsai, Yu-Pao [3 ]
Lo, Wan-Yen [1 ,2 ]
Shih, Sheng-Wen [4 ]
Hung, Yi-Ping [1 ,2 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Grad Inst Networking & Multimedia, Taipei 106, Taiwan
[3] Acad Sinica, Inst Informat Sci, Taipei 105, Taiwan
[4] Natl Chi Nan Univ, Dept Comp Sci & Informat Engn, Nantou 545, Taiwan
关键词
object movie; camera calibration; CPC kinematic model; 3D reconstruction; motorized; object rig;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Object Movies (OMs) have been successfully used in many applications. However, the techniques for acquiring OMs still need to be improved if high-quality and efficient OMs are desired. In this paper, we present a method for calibrating a motorized object rig to facilitate the acquisition of OMs. We first apply the CPC kinematic model to formulate the 3D configuration of the device, and then propose a method to estimate the parameters of the CPC model of the device. Furthermore, a visual tool is provided for users to adjust the controllable axes of the rig according to the estimated results. After this calibration, more accurate camera parameters can be obtained and then be used for different purposes. In this work, we use the parameters to reconstruct, from an OM, the 3D model of the 3D object, and then adjust the OM according to the center of the 3D model so that a high-quality OM can be obtained for rendering.
引用
收藏
页码:1551 / 1565
页数:15
相关论文
共 50 条
  • [31] Design and Fabrication of Test Rig for Flow Calibration in Transformers
    Abbas, Naseem
    Mukhtar, M. Arshad
    Zahra, Nida
    Ali, M. Aon
    Ahmed, Syed Faiz
    Ali, Athar
    2017 4TH IEEE INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGIES AND APPLIED SCIENCES (ICETAS), 2017,
  • [32] Further investigation into a water flow rig related to calibration
    Shimada, Takashi
    Mahadeva, Dharshanie V.
    Baker, Roger C.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (04) : 462 - 475
  • [33] Vision Based Localization Stereo Rig Calibration and Rectification
    Ciocoiu, Titus Iulian
    Moldoveanu, Florin Dumitru
    2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), 2017, : 1013 - 1018
  • [34] Motorized valve for cryogenic applications in space laboratories
    Wiessner, FG
    PROCEEDINGS OF THE 8TH EUROPEAN SPACE MECHANISMS AND TRIBOLOGY SYMPOSIUM, 1998, 438 : 187 - 189
  • [35] WORLDS LARGEST FLOW CALIBRATION RIG ENSURES ACCURACY
    不详
    PROCESS ENGINEERING, 1979, (OCT) : 47 - 47
  • [36] MINIMUM SPACE PLATFORM RIG (MSPR) - ITS ADAPTABILITY TO ONSHORE DRILLING APPLICATIONS.
    Hayes, B.J.
    JPT, Journal of Petroleum Technology, 1985, 37 (10): : 1633 - 1639
  • [37] Sensor Fusion for Force and Position Calibration of a Motorized Surgical Smart Grasper
    Kaplan, Jack
    Sosnovskaya, Yana
    Arnold, Matthew
    Hannaford, Blake
    2021 INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS (ISMR), 2021,
  • [38] Unified calibration technique and its applications in optical triangular profilometry
    Asundi, A
    Zhou, W
    APPLIED OPTICS, 1999, 38 (16) : 3556 - 3561
  • [39] A model of an electro-goniometer and its calibration for biomechanical applications
    Legnani, G
    Zappa, B
    Casolo, F
    Adamini, R
    Magnani, PL
    MEDICAL ENGINEERING & PHYSICS, 2000, 22 (10) : 711 - 722
  • [40] High Precision SEIS Calibration for the InSight Mission and Its Applications
    L. Pou
    D. Mimoun
    P. Lognonne
    R. F. Garcia
    O. Karatekin
    M. Nonon-Latapie
    R. Llorca-Cejudo
    Space Science Reviews, 2019, 215