Intraperitoneal pressure in peritoneal dialysis

被引:30
|
作者
Perez Diaz, Vicente [1 ,2 ]
Sanz Ballesteros, Sandra [1 ]
Hernandez Garcia, Esther [3 ]
Descalzo Casado, Elena [4 ]
Herguedas Callejo, Irene [4 ]
Ferrer Perales, Cristina [1 ]
机构
[1] Hosp Clin Univ Valladolid, Serv Nefrol, Valladolid, Spain
[2] Univ Valladolid, Fac Med, Dept Med Dermatol & Toxicol, Valladolid, Spain
[3] Complejo Asistencial Univ Palencia, Serv Nefrol, Palencia, Spain
[4] Univ Valladolid, Fac Med, Valladolid, Spain
来源
NEFROLOGIA | 2017年 / 37卷 / 06期
关键词
Intraperitoneal pressure; Hydrostatic pressure; Ultrafiltration; Ultrafiltration failure; Mechanical complications of; peritoneal dialysis; Infusion volume; FILL-VOLUME; ULTRAFILTRATION FAILURE; SOLUTE TRANSPORT; BODY-SIZE; CHILDREN; FLUID; IMPACT; CAPD; COMPLICATIONS; TOLERANCE;
D O I
10.1016/j.nefro.2017.05.014
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The measure of intraperitoneal pressure in peritoneal dialysis is easy and provides clear therapeutic benefits. However it is measured only rarely in adult peritoneal dialysis units. This review aims to disseminate the usefulness of measuring intraperitoneal pressure. This measurement is performed in supine before initiating the drain of a manual exchange with "Y" system, by raising the drain bag and measuring from the mid-axillary line the height of the liquid column that rises from the patient. With typical values of 10-16 cm H2O, intraperitoneal pressure should never exceed 18 cm H2O. With basal values that depend on body mass index, it increases 1-3 cm H2O/L of intraperitoneal volume, and varies with posture and physical activity. Its increase causes discomfort, sleep and breathing disturbances, and has been linked to the occurrence of leaks, hernias, hydrothorax, gastro-esophageal reflux and enteric peritonitis. Less known and valued is its ability to decrease the effectiveness of dialysis significantly counteracting ultrafiltration and decreasing solute clearance to a smaller degree. Because of its easy measurement and potential utility, should be monitored in case of ultrafiltration failure to rule out its eventual contribution in some patients. Although not yet mentioned in the clinical practice guidelines for PD, its clear benefits justify its inclusion among the periodic measurements to consider for prescribing and monitoring peritoneal dialysis. (c) 2017 Sociedad Espanola de Nefrologia. Published by Elsevier Espana,S.L.U.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 50 条
  • [21] An unusual intraperitoneal repair of a peritoneal dialysis catheter
    Misra, M
    Khanna, R
    Nichols, WK
    PERITONEAL DIALYSIS INTERNATIONAL, 1998, 18 (03): : 339 - 341
  • [22] THE EFFECT OF CLEAN INTERMITTENT CATHETERIZATION ON INTRAPERITONEAL PRESSURE IN PERITONEAL DIALYSIS PATIENTS WITH NEUROPATHIC BLADDER
    Serdaroglu, Erkin
    Toktay, Aysen
    Gozmen, Sukran Keskin
    PEDIATRIC NEPHROLOGY, 2018, 33 (10) : 1890 - 1890
  • [23] CORRELATION OF INTRAPERITONEAL PRESSURE AND APEX TIME WITH ULTRAFILTRATION AND BIOCHEMICAL VARIABLES IN PATIENTS IN PERITONEAL DIALYSIS
    Vargas Arispe, Lionel Cristian
    Amador Reyes, Laura Gabriela
    Valdez Ortiz, Rafael
    Perez Navarro, Lucia Monserrat
    Paredes Fernajndez, Carlos Mauricio
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36 : 398 - 398
  • [24] Use of intraperitoneal hydration by peritoneal dialysis fluid as a complementary palliative therapy in peritoneal dialysis patients
    Zeiler, Matthias
    Fioravanti, Gilda
    Angelini, Andrea
    Silvestri, Simona
    Fioravanti, Giuseppe
    Santarelli, Stefano
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I2615 - I2615
  • [25] Use of intraperitoneal hydration by peritoneal dialysis fluid as a complementary palliative therapy in peritoneal dialysis patients
    Zeiler, Matthias
    Fioravanti, Gilda
    Angelini, Andrea
    Silvestri, Simona
    Fioravanti, Giuseppe
    Santarelli, Stefano
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [26] Intraperitoneal hydrostatic pressure and flow characteristics of peritoneal catheters in automated peritoneal dialysis (vol 18, pg 2391, 2003)
    Scanziani, R
    Dozio, B
    Baragetti, I
    Maroni, S
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (03) : 754 - 754
  • [27] The prognostic values of estimating intraperitoneal pressure in the occurrence of abdominal wall complications in peritoneal dialysis patients
    Ma, Tiantian
    Li, Xinqiu
    Hao, Jiayu
    Song, Di
    Wang, Hongyan
    Liu, Tianjiao
    Zhang, Yaling
    Abi, Nanzha
    Xu, Xiao
    Dong, Jie
    JOURNAL OF NEPHROLOGY, 2024, 37 (5) : 1351 - 1360
  • [28] INFLUENCE OF INTRAPERITONEAL DIALYSATE ON BLOOD-PRESSURE DURING CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS
    FLEMING, SJ
    POWELL, J
    BAKER, LRI
    CATTELL, WR
    GREENWOOD, R
    CLINICAL NEPHROLOGY, 1983, 19 (03) : 132 - 133
  • [29] Intraperitoneal Pressure in Polycystic and Non-Polycystic Kidney Disease Patients, Treated by Peritoneal Dialysis
    Giuliani, Anna
    Milan Manani, Sabrina
    Crepaldi, Carlo
    Domenici, Alessandro
    Gastaldon, Fiorella
    Corradi, Valentina
    Ronco, Claudio
    BLOOD PURIFICATION, 2020, 49 (06) : 670 - 676
  • [30] Use of intraperitoneal pressure, ultrafiltration and purification dwell times for individual peritoneal dialysis prescription in children
    Fischbach, M
    Desprez, P
    Terzic, J
    Lahlou, A
    Mengus, L
    Geisert, J
    CLINICAL NEPHROLOGY, 1996, 46 (01) : 14 - 16