Intraperitoneal pressure in peritoneal dialysis

被引:30
|
作者
Perez Diaz, Vicente [1 ,2 ]
Sanz Ballesteros, Sandra [1 ]
Hernandez Garcia, Esther [3 ]
Descalzo Casado, Elena [4 ]
Herguedas Callejo, Irene [4 ]
Ferrer Perales, Cristina [1 ]
机构
[1] Hosp Clin Univ Valladolid, Serv Nefrol, Valladolid, Spain
[2] Univ Valladolid, Fac Med, Dept Med Dermatol & Toxicol, Valladolid, Spain
[3] Complejo Asistencial Univ Palencia, Serv Nefrol, Palencia, Spain
[4] Univ Valladolid, Fac Med, Valladolid, Spain
来源
NEFROLOGIA | 2017年 / 37卷 / 06期
关键词
Intraperitoneal pressure; Hydrostatic pressure; Ultrafiltration; Ultrafiltration failure; Mechanical complications of; peritoneal dialysis; Infusion volume; FILL-VOLUME; ULTRAFILTRATION FAILURE; SOLUTE TRANSPORT; BODY-SIZE; CHILDREN; FLUID; IMPACT; CAPD; COMPLICATIONS; TOLERANCE;
D O I
10.1016/j.nefro.2017.05.014
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The measure of intraperitoneal pressure in peritoneal dialysis is easy and provides clear therapeutic benefits. However it is measured only rarely in adult peritoneal dialysis units. This review aims to disseminate the usefulness of measuring intraperitoneal pressure. This measurement is performed in supine before initiating the drain of a manual exchange with "Y" system, by raising the drain bag and measuring from the mid-axillary line the height of the liquid column that rises from the patient. With typical values of 10-16 cm H2O, intraperitoneal pressure should never exceed 18 cm H2O. With basal values that depend on body mass index, it increases 1-3 cm H2O/L of intraperitoneal volume, and varies with posture and physical activity. Its increase causes discomfort, sleep and breathing disturbances, and has been linked to the occurrence of leaks, hernias, hydrothorax, gastro-esophageal reflux and enteric peritonitis. Less known and valued is its ability to decrease the effectiveness of dialysis significantly counteracting ultrafiltration and decreasing solute clearance to a smaller degree. Because of its easy measurement and potential utility, should be monitored in case of ultrafiltration failure to rule out its eventual contribution in some patients. Although not yet mentioned in the clinical practice guidelines for PD, its clear benefits justify its inclusion among the periodic measurements to consider for prescribing and monitoring peritoneal dialysis. (c) 2017 Sociedad Espanola de Nefrologia. Published by Elsevier Espana,S.L.U.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 50 条
  • [1] Continuous ambulatory peritoneal dialysis and intraperitoneal pressure
    Yankovoy, Andrey
    Vatasin, Andrey
    Astachov, Pavel
    Smoliakov, Aleks
    Shuvalova, Valentina
    Kulibaba, Svetlana
    Losev, Grigoriy
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 303 - 303
  • [2] Intraperitoneal pressure and hernias in children on peritoneal dialysis
    Rosemeri A. Aranda
    João E. Romão Jr.
    Emília Kakehashi
    Wagner Domingos
    Emil Sabbaga
    Marcello Marcondes
    Hugo Abensur
    Pediatric Nephrology, 2000, 14 : 22 - 24
  • [3] Intraperitoneal pressure and hernias in children on peritoneal dialysis
    Aranda, RA
    Romao, JE
    Kakehashi, E
    Domingos, W
    Sabbaga, E
    Marcondes, M
    Abensur, H
    PEDIATRIC NEPHROLOGY, 2000, 14 (01) : 22 - 24
  • [4] Relationship between intraperitoneal volume and intraperitoneal pressure during peritoneal dialysis
    Zhu, Fansan
    Merlo, Laura Rosales
    Tisdale, Lela
    Villamar, Maricar
    Yi, Jun
    Wang, Xiaoling
    Grobe, Nadja
    Fischer, Karsten
    Plahey, Kulwinder
    Chamney, Paul
    Schiller, Brigitte
    Kotanko, Peter
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I1500 - I1501
  • [5] Relationship between intraperitoneal volume and intraperitoneal pressure during peritoneal dialysis
    Zhu, Fansan
    Merlo, Laura Rosales
    Tisdale, Lela
    Villamar, Maricar
    Yi, Jun
    Wang, Xiaoling
    Grobe, Nadja
    Fischer, Karsten
    Plahey, Kulwinder
    Chamney, Paul
    Schiller, Brigitte
    Kotanko, Peter
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [6] CLINICAL RELEVANCE OF INTRAPERITONEAL PRESSURE IN PERITONEAL DIALYSIS PATIENTS
    Betancourt Castellanos, Loreley
    Ponz Clemente, Esther
    Blasco Cabanas, Conchita
    Marquina Parra, Dolors
    Bolos Contador, Mabel
    Oliva Morera, Juan Carlos
    Almirall Daly, Jaume
    PERITONEAL DIALYSIS INTERNATIONAL, 2017, 37 (05): : 562 - 567
  • [7] Intraperitoneal hydrostatic pressure and flow characteristics of peritoneal catheters in automated peritoneal dialysis
    Scanziani, R
    Dozio, B
    Baragetti, I
    Maroni, S
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2003, 18 (11) : 2391 - 2398
  • [8] Association of intraperitoneal pressure and clinical symptoms in peritoneal dialysis patients
    郝佳玉
    China Medical Abstracts(Internal Medicine), 2023, 40 (03) : 181 - 181
  • [9] Prognostic value of high intraperitoneal pressure in patients on peritoneal dialysis
    Betancourt, Loreley
    Ponz, Esther
    Grau, Carmen
    Comas, Carla
    Vidiella, Joan
    Gordo, Maria jose
    Almirall, Jaume
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2025,
  • [10] Intraperitoneal Pressure Has a Prognostic Impact on Peritoneal Dialysis Patients
    Outerelo, Maria Cristina
    Gouveia, Rita
    Teixeira e Costa, Fernando
    Ramos, Aura
    PERITONEAL DIALYSIS INTERNATIONAL, 2014, 34 (06): : 652 - 654