Whole-body MRA

被引:16
|
作者
Kramer, Harald [1 ]
Quick, Harald H. [2 ]
Tombach, Bernd [3 ,4 ]
Schoenberg, Stefan O. [5 ]
Barkhausen, Joerg [2 ]
机构
[1] Univ Munich, Univ Hosp Munich, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[3] Univ Munster, Dept Clin Radiol, Munster, Germany
[4] Klinikum Osnabruck Rontgen & Strahlenklin, Osnabruck, Germany
[5] Univ Heidelberg, Med Fac Mannheim, Univ Hosp Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
关键词
MRI; MRA; whole-body imaging; whole-body MRA; atherosclerosis;
D O I
10.1007/s00330-007-0817-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vascular diseases today constitute a serious health burden, ranking atherosclerosis as number one in the morbidity and mortality statistics of developed countries, with a still-growing incidence. Different treatment options are available for all vascular territories, ranging from conservative pharmacological treatment and catheter-based interventions up to surgical methods with remodelling of the vessels or bypass implantation. For treatment planning, all listed procedures have in common that they rely on initial diagnostic imaging to assess the degree and extent of stenoses. In this respect, imaging of the arterial system from the head down to the feet seems to be reasonable. Up to now no imaging technique allowed the assessment of the complete arterial system in only one exam within a reasonable time and without limiting factors like invasiveness and ionizing radiation. However, recent developments in magnetic resonance (MR) hardware and software, such as dedicated whole-body MR systems with specially designed surface coils, the movement to higher field strength and the implementation of parallel acquisition techniques (PAT), have helped to overcome the long-standing limitations of MR angiography (MRA), like reduced spatial resolution, long acquisition time, the restriction to body parts and only one field of view of a maximum 50 cm.
引用
收藏
页码:1925 / 1936
页数:12
相关论文
共 50 条
  • [21] WHOLE-BODY AUTORADIOGRAPHY
    LARSSON, B
    ULLBERG, S
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1981, 29 (NA1) : 216 - 225
  • [22] WHOLE-BODY PLETHYSMOGRAPHY
    MATTHYS, H
    PNEUMONOLOGIE-PNEUMONOLOGY, 1971, 146 (03): : 216 - &
  • [23] WHOLE-BODY COUNTERS
    REMENCHI.AP
    MILLER, CE
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 197 (01): : 47 - &
  • [24] WHOLE-BODY VIBRATION
    不详
    LANCET, 1977, 1 (8020): : 1040 - 1041
  • [25] AND NOW WHOLE-BODY
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1975, 2 (5966): : 300 - 300
  • [26] WHOLE-BODY OPACIFICATION
    CREMIN, BJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1979, 132 (05) : 857 - 857
  • [27] Whole-body plethysmography
    Criee, C. -P.
    PNEUMOLOGE, 2009, 6 (05): : 337 - 344
  • [28] WHOLE-BODY COUNTING
    ROESCH, WC
    HEALTH PHYSICS, 1965, 11 (09): : 945 - +
  • [29] WHOLE-BODY MONITORS
    GODFREY, BE
    VENNART, J
    COTTRALL, MF
    TROTT, NG
    BODDY, K
    BRITISH JOURNAL OF RADIOLOGY, 1968, 41 (482): : 155 - &
  • [30] STUDIES IN WHOLE-BODY POTASSIUM AND WHOLE-BODY NITROGEN IN NEWLY DIAGNOSED DIABETICS
    WALSH, CH
    SOLER, NG
    JAMES, H
    HARVEY, TC
    THOMAS, BJ
    FREMLIN, JH
    FITZGERALD, MG
    MALINS, JM
    QUARTERLY JOURNAL OF MEDICINE, 1976, 45 (178): : 295 - 301