Experimental Study on Prestressing Force of Corroded Prestressed Concrete Steel Strands

被引:9
|
作者
Li, Jingyuan [1 ]
Miki, Tomohiro [1 ]
Yang, Qiuning [2 ]
Mao, Mingjie [2 ]
机构
[1] Kobe Univ, Dept Civil Engn, Kobe, Japan
[2] Ningxia Univ, Sch Civil & Hydraul Engn, Yinchuan, Ningxia, Peoples R China
基金
日本学术振兴会;
关键词
FLEXURAL BEHAVIOR; CORROSION;
D O I
10.3151/jact.20.550
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents the effect of corrosion of prestressed concrete (PC) strands on the prestressing force and the reduction mechanism of the uniaxial force. A total of 14 strands was tested by combining a rigid frame testing machine with an electrified accelerated corrosion device. The specimens were divided into two groups having prestressing levels of 70% and 50% of tensile strength of PC strands. The expected degree of corrosion of the specimens, which was defined by the mass loss, was calculated from controlled electric current and time. A rigid frame testing machine was used to sustain the tensile force of the PC strands, and the prestressing force and deformation of the strand were continuously measured during the corrosion test. The test results indicate that the prestressing force decreases with the increase of corrosion. After the corrosion tests, tensile loading tests were carried out on the specimens that did not rupture during the corrosion test. It was found that corrosion led to the deterioration of the tensile properties of the PC strands, and the ultimate tensile capacity of the corroded PC strand was related to the fracture condition.
引用
收藏
页码:550 / 563
页数:14
相关论文
共 50 条
  • [21] Corrosion Morphology and Mechanical Behavior of Corroded Prestressing Strands
    Wang, Lei
    Li, Tang
    Dai, Lizhao
    Chen, Wen
    Huang, Ke
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2020, 18 (10) : 545 - 557
  • [22] FRACTURE BEHAVIOR OF STEEL STRANDS CORRODED IN CONCRETE CONTAMINATED WITH SALT
    Li, F. M.
    Yuan, Y. S.
    Jiang, J. H.
    Du, J. M.
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 669 - 675
  • [23] Experimental study on the fire performance of prestressed steel parallel wire strands
    Selamet, Serdar
    Ozer, Abdullah Yusuf
    Ildan, Kerem Bulut
    ENGINEERING STRUCTURES, 2023, 280
  • [24] Response of corroded prestressed beams with bonded strands
    Castel, Arnaud
    Coronelli, Dario
    Francois, Raoul
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (05) : 233 - 244
  • [25] Corrosion propagation of prestressing steel strands in concrete subject to chloride attack
    Li, Fumin
    Yuan, Yingshu
    Li, Chun-Qing
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (10) : 3878 - 3885
  • [26] A prototype test study on the reinforcement effect of prestressed concrete cylinder pipe with external prestressed steel strands
    Zhao L.
    Dou T.
    Cheng B.
    Xia S.
    Zhang T.
    Bi R.
    Shuili Xuebao/Journal of Hydraulic Engineering, 2019, 50 (07): : 844 - 853
  • [27] Bond of 13 mm prestressing steel strands in pretensioned concrete members
    Marti-Vargas, J. R.
    Serna, P.
    Navarro-Gregori, J.
    Pallares, L.
    ENGINEERING STRUCTURES, 2012, 41 : 403 - 412
  • [28] Splitting failure of precast prestressed concrete during the release of the prestressing force
    Galvez, J. C.
    Benitez, J. M.
    Tork, B.
    Casati, M. J.
    Cendon, D. A.
    ENGINEERING FAILURE ANALYSIS, 2009, 16 (08) : 2618 - 2634
  • [29] IDENTIFICATION OF LIFE CYCLE PRESTRESSING FORCE IN EXISTING PRESTRESSED CONCRETE BRIDGE
    Zhong, Qing
    Yao, Hongxu
    INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 351 - 356
  • [30] Experimental Study on the Influence of Type of Stirrup of Prestressed Concrete Beams with Corroded Rebars
    Li, Fang-Yuan
    Li, Liu-Yang
    Li, Wen-Hao
    Wu, Peifeng
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022