Utilization of Thoracic Ultrasound for Confirmation of Central Venous Catheter Placement and Exclusion of Pneumothorax: A Novel Technique in Real-Time Application

被引:14
|
作者
Raman, Dileep [1 ]
Sharma, Manish [1 ]
Moghekar, Ajit [1 ]
Wang, Xiaofeng [2 ]
Hatipoglu, Umur [1 ]
机构
[1] Cleveland Clin, Resp Inst, Cleveland, OH 44106 USA
[2] Cleveland Clin, Quantitat Hlth Sci, Cleveland, OH 44106 USA
关键词
central venous catheter; ultrasound; chest radiograph; portable chest X-ray; VEIN CATHETER; SALINE FLUSH;
D O I
10.1177/0885066617705839
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: To evaluate the safety and utility of ultrasonography as a tool to confirm central venous catheter (CVC) position and to exclude insertion-related pneumothorax in place of chest radiography (CXR) in a tertiary medical intensive care unit (ICU). Methods: We randomized 60 consecutive medical ICU patients to conventional or ultrasound groups for CVC placement. Both groups had CVCs inserted under ultrasound guidance. The intervention group underwent real-time transthoracic echocardiography to assist in catheter positioning and chest ultrasonography for exclusion of pneumothorax. Our primary end point was reduction in CXR use. The secondary end point was time elapsed from the end of procedure to the availability of CVC for use. chi(2) test was used to compare the 2 groups for the primary end point. T test was used to compare the 2 groups for the secondary end point. Results: Thirty patients were randomized to the conventional group and 30 were randomized to the ultrasound group. One patient was excluded in the control group since the procedure needed to be aborted. Patient characteristics were well matched for age, body mass index, and acute physiologic assessment and chronic health evaluation (APACHE III) scores. There was a 56.7% (P < .0001) reduction in CXR use in the ultrasound arm. Mean time to use was 53.6 minutes in the control group and 25 minutes in the ultrasound arm (P = .0015). Mean time required to complete the procedure was 27.7 minutes in the control group and 24.1 minutes in the ultrasound group (P = .2053). No pneumothorax was detected in either arm. Conclusion: Ultrasound-guided CVC placement and positioning with a minor modification in technique reduced the use of bedside CXR and reduced the time to use of the CVC.
引用
收藏
页码:594 / 598
页数:5
相关论文
共 50 条
  • [41] Real-time ultrasonography for placement of central venous catheters in children: A multi-institutional study
    Gurien, Lori A.
    Blakely, Martin L.
    Russell, Robert T.
    Streck, Christian J.
    Vogel, Adam M.
    Renaud, Elizabeth J.
    Savoie, Kate B.
    Dassinger, Melvin S.
    SURGERY, 2016, 160 (06) : 1605 - 1611
  • [42] Real-time transfontanellar ultrasound-guided biventricular catheter placement for revision surgery: technical note
    Secer, Mehmet
    Varlibas, Zeynep Nigar
    Nacar, Osman Arikan
    Cinar, Kadir
    Ulutas, Murat
    EGYPTIAN JOURNAL OF NEUROSURGERY, 2019, 34 (01)
  • [43] Real-time transfontanellar ultrasound-guided biventricular catheter placement for revision surgery: technical note
    Mehmet Seçer
    Zeynep Nigar Varlıbaş
    Osman Arıkan Nacar
    Kadir Çınar
    Murat Ulutaş
    Egyptian Journal of Neurosurgery, 34
  • [44] Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter
    Wright, Matthew
    Harks, Erik
    Deladi, Szabolcs
    Suijver, Freek
    Barley, Maya
    van Dusschoten, Anneke
    Fokkenrood, Steven
    Zuo, Fei
    Sacher, Frederic
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    HEART RHYTHM, 2011, 8 (02) : 304 - 312
  • [45] Real-time ultrasound -guided supraclavicular technique as a possible alternative approach for Hickman catheter implantation* , ** , ?
    Yamamoto, Tomohiro
    Arai, Yuhki
    Schindler, Ehrenfried
    JOURNAL OF PEDIATRIC SURGERY, 2020, 55 (06) : 1157 - 1161
  • [46] Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study
    Rubortone, Serena Antonia
    Costa, Simonetta
    Perri, Alessandro
    D'Andrea, Vito
    Vento, Giovanni
    Barone, Giovanni
    ITALIAN JOURNAL OF PEDIATRICS, 2021, 47 (01)
  • [47] Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study
    Serena Antonia Rubortone
    Simonetta Costa
    Alessandro Perri
    Vito D’Andrea
    Giovanni Vento
    Giovanni Barone
    Italian Journal of Pediatrics, 47
  • [48] A novel technique to assess internal body fat using real-time ultrasound
    Ribeiro, F. R. B.
    Tedeschil, L. O.
    Stoffer, J.
    Carstens, G. E.
    JOURNAL OF ANIMAL SCIENCE, 2007, 85 : 601 - 601
  • [49] A novel technique to assess internal body fat using real-time ultrasound
    Ribeiro, F. R. B.
    Tedeschi, L. O.
    Stoffer, J.
    Carstens, G. E.
    JOURNAL OF DAIRY SCIENCE, 2007, 90 : 601 - 601
  • [50] A novel technique to assess internal body fat using real-time ultrasound
    Ribeiro, F. R. B.
    Tedeschi, L. O.
    Stoffer, J.
    Carstens, G. E.
    POULTRY SCIENCE, 2007, 86 : 601 - 601