Wavefront-optimized excimer laser in situ keratomileusis for myopia and myopic astigmatism: Refractive outcomes and corneal densitometry

被引:36
|
作者
Fares, Usama [1 ]
Otri, Ahamd Muneer [1 ]
Al-Aqaba, Mouhamed Ali [1 ]
Faraj, Lana [1 ]
Dua, Harminder S. [1 ]
机构
[1] Univ Nottingham, Div Ophthalmol & Visual Sci, Nottingham NG7 2RD, England
来源
关键词
PHOTOREFRACTIVE KERATECTOMY; FEMTOSECOND LASER; FLAP CREATION; GUIDED LASIK; FELLOW EYES; SURGERY; METAANALYSIS; ABERRATIONS; ALLEGRETTO; INTRALASE;
D O I
10.1016/j.jcrs.2012.07.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the refractive outcomes of wavefront-optimized laser in situ keratomileusis (LASIK) treatments, in particular to measure corneal densitometry after LASIK using the densitometry function of the Pentacam Scheimpflug system. SETTING: Division of Ophthalmology and Visual Sciences, University of Nottingham, United Kingdom. DESIGN: Cohort study. METHODS: Changes in postoperative visual acuity, refraction, and contrast sensitivity were evaluated after wavefront-optimized laser treatment. Corneal densitometry was evaluated with the Scheimpflug system before and after LASIK. RESULTS: One year postoperatively, the uncorrected distance visual acuity was 6/6 or better in 92% of eyes and 6/9 or better in all eyes. Eighty-six percent of eyes had no change in the corrected distance visual acuity (CDVA); 4% gained 1 or more lines. Wavefront-optimized LASIK was stable over 1 year postoperatively. Eighty-nine percent of eyes were within +/- 0.50 diopter (D) and 100% were within +/- 1.00 D of the intended correction 1 year postoperatively. Contrast sensitivity showed a nonsignificant improvement (1.55 +/- 0.10 [SD] preoperatively to 1.57 +/- 0.09 12 months postoperatively) (P > .05). There was a nonsignificant increase in corneal densitometry 1 year postoperatively (from 12.72 +/- 2.43 to 13.04 +/- 2.58) (P > .05). No correlation was found between corneal densitometry and contrast sensitivity or CDVA. CONCLUSIONS: Wavefront-optimized LASIK gave excellent refractive and visual outcomes and did not seem to affect corneal densitometry significantly 1 year postoperatively. However, larger studies may show a masked effect on corneal densitometry. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. J Cataract Refract Surg 2012; 38:2131-2138 (C) 2012 ASCRS and ESCRS
引用
收藏
页码:2131 / 2138
页数:8
相关论文
共 50 条
  • [41] Objective and subjective preoperative refraction techniques for wavefront-optimized and wavefront-guided laser in situ keratomileusis
    Perez-Straziota, Claudia E.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02): : 256 - 259
  • [42] Nomogram adjustment of laser in situ keratomileusis for myopia and myopic astigmatism with the Alcon LADARVision system
    Caster, AI
    Hoff, JL
    Ruiz, R
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (04) : 364 - 370
  • [43] EXCIMER-LASER SURGERY FOR MYOPIA AND MYOPIC ASTIGMATISM
    HADDEN, OB
    MORRIS, AT
    RING, CP
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1995, 23 (03): : 183 - 188
  • [44] Correlation between estimated and measured corneal ablation and refractive outcomes in laser in situ keratomileusis for myopia
    Lackerbauer, Carl-Arnold
    Grueterich, Martin
    Ulbig, Michael
    Kampik, Anselm
    Kojetinsky, Corina
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08): : 1343 - 1347
  • [45] Prospective, Randomized, Contralateral Eye Comparison of Wavefront-Guided and Wavefront-Optimized Laser in Situ Keratomileusis
    Roe, Joshua R.
    Manche, Edward E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 175 - 183
  • [46] Comparative analysis of visual outcomes and ocular aberrations following wavefront optimized and topography-guided customized femtosecond laser in situ keratomileusis for myopia and myopic astigmatism: A contralateral eye study
    Tiwari, Nitin N.
    Sachdev, Gitansha S.
    Ramamurthy, Shreyas
    Dandapani, Ramamurthy
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1558 - 1561
  • [47] Laser in situ keratomileusis with a scanning excimer laser for the correction of low to moderate myopia with and without astigmatism
    Balazsi, G
    Mullie, M
    Lasswell, L
    Lee, PA
    Duh, YJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (12): : 1942 - 1951
  • [48] Results of correction of myopic and myopic astigmatism with laser assistent in situ intraestromal keratomileusis with the Aescularp Meditec Excimer Laser Unit
    Rodriguez, JL
    Gomez, A
    Alcivar, R
    Graue, E
    Suarez, R
    Ramirez, T
    Climent, A
    Moreno, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1958 - 1958
  • [49] Wavefront-optimized laser in situ keratomileusis with the Allegretto Wave Eye-Q excimer laser and the FEMTO LDV Crystal Line femtosecond laser: 6 month visual and refractive results
    Ziaei, Mohammed
    Mearza, Ali A.
    Allamby, David
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (04): : 245 - 249
  • [50] Time course of refractive and corneal astigmatism after laser in situ keratomileusis for moderate to high astigmatism
    Igarashi, Akihito
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Komatsu, Mari
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08): : 1408 - 1413