Influence of Defect Pressure on Insulation Characteristics of Molded Transformer Model

被引:0
|
作者
Nakamura, Yusuke [1 ]
Cho, Hiroaki [1 ]
Takeuchi, Miwa [1 ]
Maeda, Teruhiko [2 ]
机构
[1] Toshiba Co Ltd, Power & Ind Syst R&D Ctr, Fuchu, Tokyo, Japan
[2] Toshiba Ind Prod & Syst Corp, Technol Planning Dept, Asahi, Mie, Japan
关键词
Molded Transformer; Partial Discharge; Lifetime; Pressure in Defect;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper discusses the influence of pressure in a defect on time evolution of Partial discharge (PD) characteristics and lifetime characteristics of an insulation model of a molded transformer. Experimental results show that the time evolution of PD characteristics for a defect at atmospheric pressure is different from that for a defect at a reduced pressure. Secondly, the lifetime of a sample with an atmospheric pressure defect is short, since samples containing a defect at atmospheric pressure can lead to breakdown with a small amount of PD charge
引用
收藏
页码:705 / 708
页数:4
相关论文
共 50 条
  • [21] Voltage Transfer Characteristics of an Insulation Transformer Up to 1 MHz
    Kim, Kwangho
    Kim, Sungjun
    Nah, Wansoo
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (04) : 1207 - 1216
  • [22] Insulation Characteristics of Deformed Transformer Winding under Transient Impulse
    Ye, Haifeng
    Tian, Xiang
    Wu, Hao
    Li, Yabo
    Wu, Zhen
    Ma, Guoming
    Li, Chengrong
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 552 - 555
  • [23] An Updated Model to Determine the Life Remaining of Transformer Insulation
    Martin, Daniel
    Cui, Yi
    Ekanayake, Chandima
    Ma, Hui
    Saha, Tapan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (01) : 395 - 402
  • [24] The influence of oil speed and temperature on PD phenomena in transformer insulation
    Azcarraga, C. G.
    Cavallini, A.
    Montanari, G. C.
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 494 - 497
  • [25] Pressure characteristics of a variable hydraulic transformer
    Yang G.
    Jiang J.
    Jiang, Jihai (jjhlxw@hit.edu.cn), 1600, Bentham Science Publishers (09): : 311 - 329
  • [26] Analysis and treatment of a type of 110-kV transformer with insulation resistance decline defect
    Zhang, Li
    Su, Wei
    Qian, Yihua
    Chen, Tiansheng
    Fan, Shengping
    Fu, Qiang
    Zhao, Yaohong
    Zhu, Zhiping
    Wang, Deng
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (11) : 1602 - 1608
  • [27] Transformer insulation aging assessment and life prediction based on variety characteristics
    Wan, Xun
    Tan, Kunyu
    Liu, Yun
    Ye, Huisheng
    Zhao, Shihua
    Peng, Ping
    Peng, Minfang
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON MEASUREMENT, INSTRUMENTATION AND AUTOMATION (ICMIA 2016), 2016, 138 : 650 - 657
  • [28] Effects of Insulation Paper Ageing on the Vibration Characteristics of a Transformer Winding Disk
    Jin, Ming
    Pan, Jie
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3560 - 3566
  • [29] DETERMINATION OF PROBABILISTIC CHARACTERISTICS OF RANDOM PROCESS OF RELATIVE WEAR OF TRANSFORMER INSULATION
    NIKITIN, YM
    ELECTRICAL TECHNOLOGY, 1973, (03): : 137 - 137
  • [30] Improvements of the Transformer Insulation XY Model Including Effect of Contamination
    Cheng, Jialu
    Werelius, Peter
    Robalino, Diego
    Ohlen, Matz
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 169 - 174