On-site mine water analysis: application note for the PDV6000plus

被引:0
|
作者
Braungardt, Charlotte B. [1 ]
Buttertfield, Martin [1 ]
Wajrak, Magdalena [1 ]
机构
[1] Univ Plymouth, Sch Geog Earth & Environm Sci, Plymouth PL4 8AA, Devon, England
关键词
mine water analysis; arsenic; voltammetry; in situ; matrix removal; chelating resin;
D O I
暂无
中图分类号
TD [矿业工程];
学科分类号
0819 ;
摘要
This study presents a matrix-removal system for metals that interfere with the determination of arsenic with a voltammetric instrument capable of on-site use. A three-step sample pre-treatment system was developed to remove Fe, Cu and Zn: filtration, adjustment,of pH (pH 5.5) and column-extraction of interfering metals using chelating resin. This set-up allowed the direct and accurate determination of As in mine waters containing up to 1500 mu g L-1 and 500 mu g L-1 Zn and confirmed interferences at higher concentrations. Column optimisation and method adaptation for rapid on-site use are discussed.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 50 条
  • [41] Validation and application of wipe sampling and portable XRF analysis as an on-site screening method for assessment of deposited aerosols in workplaces
    Nygren, O
    Aspman, O
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2004, 57 (10) : 1021 - 1028
  • [42] Comparative analysis of effluent water quality from a municipal treatment plant and two on-site wastewater treatment systems
    Garcia, Santos N.
    Clubbs, Rebekah L.
    Stanley, Jacob K.
    Scheffe, Brian
    Yelderman, Joe C., Jr.
    Brooks, Bryan W.
    CHEMOSPHERE, 2013, 92 (01) : 38 - 44
  • [43] A mobile laboratory for rapid on-site analysis of catechols from water samples with real-time results production
    Wang, Yun
    Li, Yuanyuan
    Liu, Yan
    Han, Juan
    Xia, Jinchen
    Bao, Xu
    Ni, Liang
    Tang, Xu
    RSC ADVANCES, 2016, 6 (84) : 80885 - 80895
  • [44] Enhanced biosensor performance for on-site field analysis of explosives in water using solid-phase extraction membranes
    Charles, PT
    Dingle, BM
    Van Bergen, S
    Gauger, PR
    Patterson, CH
    Kusterbeck, AW
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 2001, 5 (06): : 272 - 280
  • [45] Novel optical PVC probes for on-site detection/determination of fluoroquinolones in a solid/liquid interface: Application to the determination of Norfloxacin in aquaculture water
    Silva, Tamara I. B.
    Moreira, Felismina T. C.
    Truta, Liliana A. A. N. A.
    Sales, M. Goreti F.
    BIOSENSORS & BIOELECTRONICS, 2012, 36 (01): : 199 - 206
  • [46] Application of an integrated biomarker response index to assess ground water contamination in the vicinity of a rare earth mine tailings site
    Si, Wantong
    He, Xiaoying
    Li, Ailing
    Liu, Li
    Li, Jisheng
    Gong, Donghui
    Liu, Juan
    Liu, Jumei
    Shen, Weishou
    Zhang, Xuefeng
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (17) : 17345 - 17356
  • [47] Application of an integrated biomarker response index to assess ground water contamination in the vicinity of a rare earth mine tailings site
    Wantong Si
    Xiaoying He
    Ailing Li
    Li Liu
    Jisheng Li
    Donghui Gong
    Juan Liu
    Jumei Liu
    Weishou Shen
    Xuefeng Zhang
    Environmental Science and Pollution Research, 2016, 23 : 17345 - 17356
  • [48] Application of Multivariate Statistical Analysis to Identify Water Sources in A Coastal Gold Mine, Shandong, China
    Liu, Guowei
    Ma, Fengshan
    Liu, Gang
    Zhao, Haijun
    Guo, Jie
    Cao, Jiayuan
    SUSTAINABILITY, 2019, 11 (12):
  • [49] Application of dynamic weight-set pair analysis model in mine water inrush discrimination
    Wang T.
    Jin D.
    Liu J.
    Yang J.
    Wang X.
    Zhao W.
    Meitan Xuebao/Journal of the China Coal Society, 2019, 44 (09): : 2840 - 2850
  • [50] APPLICATION OF HYDROCHEMISTRY FOR INRUSH WATER SOURCE IDENTIFICATION IN COAL MINE: APPROACH BASED ON STATISTICAL ANALYSIS
    Sun, Linhua
    MINING SCIENCE, 2018, 25 (25) : 101 - 110