Accidental entrapment of a pulmonary artery catheter during heart transplantation

被引:0
|
作者
Bleiler, S. [1 ]
Holzamer, A. [2 ]
机构
[1] Univ Klinikum Regensburg, Klin Anasthesiol, Franz Josef Strauss Allee 11, D-93053 Regensburg, Germany
[2] Univ Klinikum Regensburg, Klin Herz Thorax & Herznahe Gefasschirurg, Regensburg, Germany
来源
ANAESTHESIST | 2020年 / 69卷 / 11期
关键词
Heart surgery; Swan-Ganz catheter; Suture; Fluoroscopy; Resternotomy;
D O I
10.1007/s00101-020-00852-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Inadvertent fixation of a Swan-Ganz pulmonary artery catheter by a suture is a rare complication. We present a case report of a patient undergoing heart transplantation in whom the catheter was fixed by a suture at the upper venous cannulation site for the cardiopulmonary bypass. After diagnostics with fluoroscopy the chest was reopened and the suture was released. The catheter could then be removed. The patient did not suffer from any consequential damage.
引用
收藏
页码:821 / 824
页数:4
相关论文
共 50 条
  • [21] Entrapment of a Swan-Ganz catheter within the right pulmonary artery ligature during right pneumonectomy
    Karagoz, Ayse Heves
    Kanbak, Meral
    Celebioglu, Bilge
    Akinci, Seda Banu
    Kara, Murat
    Dogan, Riza
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2009, 57 (01): : 81 - 83
  • [22] Accidental Entrapment of Electrical Mapping Catheter by Chiari's Network in Right Atrium during Catheter Ablation Procedure
    Sakamoto, Atsushi
    Urushida, Tsuyoshi
    Sakakibara, Tomoaki
    Sano, Makoto
    Suwa, Kenichiro
    Saitoh, Takeji
    Saotome, Masao
    Katoh, Hideki
    Satoh, Hiroshi
    Hayashi, Hideharu
    CASE REPORTS IN CARDIOLOGY, 2016, 2016
  • [23] Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site
    Huang, L
    Elsharydah, A
    Nawabi, A
    Cork, RC
    JOURNAL OF CLINICAL ANESTHESIA, 2004, 16 (07) : 557 - 559
  • [24] Consistency in pulmonary artery catheter monitoring after heart transplantation and the missed detection of graft dysfunction
    Jan, M. K.
    Jernryd, V.
    Nilsson, J.
    Metzsch, C.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (04) : 542 - 542
  • [25] Entrapment of a Kinked Catheter in the Radial Artery During Transradial Coronary Angiography
    Kim, Ju-Youn
    Moon, Keon-Woong
    Yoo, Ki-Dong
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (01): : E3 - E4
  • [26] A retained catheter fragment in radial artery caused by accidental catheter transection during arterial catheter removal
    Seung-Ki Moon
    Jae-Chul Gong
    Jun-Hyun Kim
    Kyu Chang Lee
    Hye Young Kim
    Eun Kyung Choi
    Myeong Jong Lee
    Journal of Anesthesia, 2012, 26 : 625 - 626
  • [27] A retained catheter fragment in radial artery caused by accidental catheter transection during arterial catheter removal
    Moon, Seung-Ki
    Gong, Jae-Chul
    Kim, Jun-Hyun
    Lee, Kyu Chang
    Kim, Hye Young
    Choi, Eun Kyung
    Lee, Myeong Jong
    JOURNAL OF ANESTHESIA, 2012, 26 (04) : 625 - 626
  • [28] An unusual journey of a pulmonary artery catheter through the heart
    Abdo, Wilson F.
    van der Hoeven, Johannes G.
    INTENSIVE CARE MEDICINE, 2015, 41 (05) : 916 - 917
  • [29] An unusual journey of a pulmonary artery catheter through the heart
    Wilson F. Abdo
    Johannes G. van der Hoeven
    Intensive Care Medicine, 2015, 41 : 916 - 917
  • [30] Pulmonary artery catheter sutured to pulmonary artery trunk during cardiac surgery
    Hosoya, M
    Inomata, S
    Sukegawa, I
    Saito, S
    Toyooka, H
    ANESTHESIA AND ANALGESIA, 2003, 97 (02): : 606 - 607