High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

被引:26
|
作者
Rist, C [1 ]
Nikolaou, K
Flohr, T
Wintersperger, BJ
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Munich, Germany
[2] Siemens Med Solut, CT Div, Forchheim, Germany
关键词
multislice CT; artefacts; stents; coronary artery;
D O I
10.1007/s00330-006-0186-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265 +/- 25HU and 254 +/- 16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367 +/- 36HU versus 402 +/- 28HU, P < 0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68 +/- 0.08 mm versus 2.81 +/- 0.07 mm and 3.29 +/- 0.06 mm versus 3.18 +/- 0.07 mm (P < 0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.
引用
收藏
页码:1564 / 1569
页数:6
相关论文
共 50 条
  • [22] Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography
    Onuma, Yoshinobu
    Tanabe, Kengo
    Chihara, Ruri
    Yamamoto, Hirosada
    Miura, Yujiro
    Kigawa, Ikutaro
    Fukuda, Sachito
    Miyairi, Takeshi
    Nakajima, Hiroyoshi
    Hara, Kazuhiro
    AMERICAN HEART JOURNAL, 2007, 154 (03) : 519 - 526
  • [23] Review: 64-slice computed tomography coronary angiography accurately diagnoses coronary artery disease
    Lauer, Michael S.
    ANNALS OF INTERNAL MEDICINE, 2008, 149 (08)
  • [24] Coronary Artery-Left Atrial Fistula Displayed by 64-Slice Computed Tomography
    Chirichilli, Ilaria
    Frati, Giacomo
    Muzzi, Luigi
    Pugliese, Giuseppe
    Ricci, Massimo
    Santo, Chiara
    TEXAS HEART INSTITUTE JOURNAL, 2011, 38 (01): : 90 - 91
  • [25] The Role of 64-Slice Multidetector Computed Tomography in Detection of Subclinical Atherosclerosis of Coronary Artery
    Ahn, Youngkeun
    Jeong, Hae Chang
    Hong, Young Joon
    Sim, Doo Sun
    Yoon, Nam Sik
    Youn, Hyun Ju
    Kim, Kye Hun
    Park, Hyung Wook
    Kim, Ju Han
    Jeong, Myung Ho
    Cho, Jeong Gwan
    Park, Jong Chun
    Kang, Jung Chaee
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A62 - A62
  • [26] Diagnostic performance of 64-slice computed tomography in evaluation of coronary artery bypass grafts
    Feuchtner, Gudrun M.
    Schachner, Thomas
    Bonatti, Johannes
    Friedrich, Guy J.
    Soegner, Peter
    Klauser, Andrea
    zur Nedden, Dieter
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : 574 - 580
  • [27] Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography
    Husmann, L
    Alkadhi, H
    Boehm, T
    Leschka, S
    Schepis, T
    Koepfli, P
    Desbiolles, L
    Marincek, B
    Kaufmann, PA
    Wildermuth, S
    EUROPEAN RADIOLOGY, 2006, 16 (05) : 1111 - 1116
  • [28] Coronary Artery Fistula Detected by 64-Slice Multidetector Computed Tomography: Case Report
    Lin, Yi-Chang
    Tsai, Yi-Ting
    Lin, Chih-Yuan
    Lee, Chung-Yi
    Hong, Gou-Jieng
    Tsai, Chien-Sung
    HEART SURGERY FORUM, 2010, 13 (03): : E198 - E199
  • [29] Coronary artery bypass graft angioplasty conducted by 64-slice spiral computed tomography
    Ochala, Andrzej
    Syzdol, Marcin
    Wieja, Pawel
    Garbocz, Piotr
    Sosnowski, Maciej
    Cybulski, Wieslaw
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2011, 7 (03): : 193 - 198
  • [30] Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography
    Lars Husmann
    Hatem Alkadhi
    Thomas Boehm
    Sebastian Leschka
    Tiziano Schepis
    Pascal Koepfli
    Lotus Desbiolles
    Borut Marincek
    Philipp A. Kaufmann
    Simon Wildermuth
    European Radiology, 2006, 16 : 1111 - 1116