High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

被引:26
|
作者
Rist, C [1 ]
Nikolaou, K
Flohr, T
Wintersperger, BJ
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Munich, Germany
[2] Siemens Med Solut, CT Div, Forchheim, Germany
关键词
multislice CT; artefacts; stents; coronary artery;
D O I
10.1007/s00330-006-0186-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265 +/- 25HU and 254 +/- 16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367 +/- 36HU versus 402 +/- 28HU, P < 0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68 +/- 0.08 mm versus 2.81 +/- 0.07 mm and 3.29 +/- 0.06 mm versus 3.18 +/- 0.07 mm (P < 0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.
引用
收藏
页码:1564 / 1569
页数:6
相关论文
共 50 条
  • [1] High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography—initial experience
    Carsten Rist
    Konstantin Nikolaou
    Thomas Flohr
    Bernd J. Wintersperger
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2006, 16 : 1564 - 1569
  • [2] Ultra-high-resolution mode for the assessment of coronary artery stents - Ex vivo imaging with 64-slice computed tomography
    Rist, Carsten
    Nikolaou, Konstantin
    Flohr, Thomas
    Wintersperger, Bernd J.
    Johnson, Thorsten R.
    Reiser, Maximilian F.
    Becker, Christoph R.
    ACADEMIC RADIOLOGY, 2006, 13 (09) : 1165 - 1167
  • [3] Noninvasive coronary artery imaging using 64-slice spiral computed tomography: Initial experiences
    Ropers, D
    Anders, K
    Lell, M
    Baum, U
    Karakaya, S
    Pohle, K
    Kalender, W
    Bautz, W
    Daniel, WG
    Achenbaach, S
    CIRCULATION, 2004, 110 (17) : 522 - 522
  • [4] 64-slice computed tomography assessment of coronary artery stents:: a phantom study
    Mahnken, AH
    Mühlenbruch, G
    Seyfarth, T
    Flohr, T
    Stanzel, S
    Wildberger, JE
    Günther, RW
    Kuettner, A
    ACTA RADIOLOGICA, 2006, 47 (01) : 36 - 42
  • [5] Introduction to coronary imaging with 64-slice computed tomography
    Cademartiri, F
    Runza, G
    Belgrano, M
    Luccichenti, G
    Mollet, NR
    Malagutti, P
    Silvestrini, M
    Midiri, M
    Cova, M
    Mucelli, RP
    Krestin, GP
    RADIOLOGIA MEDICA, 2005, 110 (1-2): : 16 - 41
  • [6] Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective
    Lavi, Ronit
    Lavi, Shahar
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (05) : 813 - 814
  • [7] Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective
    Plass, Andre
    Gruenenfelder, Juerg
    Leschka, Sebastian
    Alkadhi, Hatem
    Eberli, Franz R.
    Wildermuth, Simon
    Zuend, Gregor
    Genoni, Michele
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) : 109 - 116
  • [8] Evaluation of the optimal image reconstruction interval for coronary artery imaging using 64-slice computed tomography
    Weininger, M.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Beissert, M.
    ACTA RADIOLOGICA, 2007, 48 (06) : 620 - 627
  • [9] Diagnostic accuracy of coronary angiography using 64-slice computed tomography in coronary artery disease
    Yang, Fu-Bin
    Guo, Wan-Liang
    Sheng, Mao
    Sun, Ling
    Ding, Yue-Yue
    Xu, Qiu-Qin
    Xu, Ming-Guo
    Lv, Hai-Tao
    SAUDI MEDICAL JOURNAL, 2015, 36 (10) : 1156 - 1162
  • [10] Evaluation of coronary artery in-stent patency using 64-slice computed tomography
    Zhao, Jing
    Zheng, Li-li
    Yang, Youyou
    CORONARY ARTERY DISEASE, 2011, 22 (08) : 540 - 552