Co-precipitation assisted cloud point extraction coupled with high performance liquid chromatography for the determination of estrogens in water and cosmetic samples

被引:16
|
作者
Xiao, Xiaohua [1 ]
Chen, Xiaoguang [1 ]
Xu, Xianfang [1 ]
Li, Gongke [1 ]
机构
[1] Sun Yat Sen Univ, Sch Chem & Chem Engn, Guangzhou 510275, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
PRECONCENTRATION; SEPARATION; URINE; MICROEXTRACTION; DERIVATIZATION; SPECTROMETRY; METALS; MIMICS; FOOD;
D O I
10.1039/c3ay41372a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and efficient co-precipitation assisted cloud point extraction is proposed for extraction of five estrogens [17 beta-estradiol (E2), estrone (E1), ethinyl estradiol (EE), diethyl stilbestrol (DES) and dihydro stilbestrol (DHS)] in environmental water and toner samples prior to high performance liquid chromatography analysis. It is based on the combination of co-precipitation with aluminum hydroxide and cloud point extraction with sodium dodecylsulfate to extract the target estrogens. Parameters affecting the extraction of target analytes including the concentration of aluminum hydroxide and sodium dodecylsulfate, extraction time, and blending types were investigated. Under optimum conditions, the enrichment factors were 31.7, 38.5, 28.2, 40.8 and 79.5 for E2, EE, E1, DES and DHS, respectively. A co-precipitation assisted cloud point extraction/high performance liquid chromatography method was developed and the limits of detection (LODs) were in the range of 0.2-0.7 mu g L-1. The proposed method was successfully applied for the determination of trace estrogens in environmental water and toner samples, and the recoveries ranging from 77.3 to 104.1% with RSD of 2.0-10.4% were obtained. Moreover, the present method was compared to the previously reported methods and the extraction mechanism was also discussed. The method was rapid, sensitive and suitable for the trace estrogen analysis.
引用
收藏
页码:6376 / 6381
页数:6
相关论文
共 50 条
  • [41] Salting-out assisted liquid–liquid extraction for the determination of ciprofloxacin residues in water samples by high performance liquid chromatography–diode array detector
    Teshome Gezahegn
    Bisratewongel Tegegne
    Feleke Zewge
    Bhagwan Singh Chandravanshi
    BMC Chemistry, 13
  • [42] 3D printed stir bar sorptive extraction coupled with high performance liquid chromatography for trace estrogens analysis in environmental water samples
    Zhu, Ning
    Wu, Zhekuan
    He, Man
    Chen, Beibei
    Hu, Bin
    ANALYTICA CHIMICA ACTA, 2023, 1281
  • [43] Uranium determination in water samples by liquid scintillation counting after cloud point extraction
    Eleni Constantinou
    Ioannis Pashalidis
    Journal of Radioanalytical and Nuclear Chemistry, 2010, 286 : 461 - 465
  • [44] Uranium determination in water samples by liquid scintillation counting after cloud point extraction
    Constantinou, Eleni
    Pashalidis, Ioannis
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 286 (02) : 461 - 465
  • [45] 3D printed stir bar sorptive extraction coupled with high performance liquid chromatography for trace estrogens analysis in environmental water samples
    Zhu, Ning
    Wu, Zhekuan
    He, Man
    Chen, Beibei
    Hu, Bin
    ANALYTICA CHIMICA ACTA, 2023, 1281
  • [46] Coprecipitation-assisted coacervative extraction coupled to high-performance liquid chromatography: An approach for determining organophosphorus pesticides in water samples
    Mammana, Sabrina B.
    Berton, Paula
    Camargo, Alejandra B.
    Lascalea, Gustavo E.
    Altamirano, Jorgelina C.
    ELECTROPHORESIS, 2017, 38 (9-10) : 1334 - 1343
  • [47] Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography for the Determination of Nonylphenol in Environmental Water Samples
    Yang, Yingchun
    Mo, Li
    Wang, Jinmei
    Wang, Mingwei
    Zhou, Shiyu
    CONFERENCE ON ENVIRONMENTAL POLLUTION AND PUBLIC HEALTH, VOL 1-2, 2010, : 875 - 878
  • [48] Extraction and preconcentration of polychlorinated dibenzo-p-dioxins using the cloud-point methodology -: Application to their determination in water samples by high-performance liquid chromatography
    Sanz, CP
    Ferrera, ZS
    Rodríguez, JJS
    ANALYTICA CHIMICA ACTA, 2002, 470 (02) : 205 - 214
  • [49] DETERMINATION OF ESTROGENS IN WATER SAMPLES BY IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
    Wu, Cui-Qin
    Chen, Di-Yun
    Feng, Yin-Si
    Deng, Hong-Mei
    Liu, Yong-Hui
    Zhou, Ai-Ju
    ANALYTICAL LETTERS, 2012, 45 (14) : 1995 - 2005
  • [50] Subcritical water extraction coupled to high-performance liquid chromatography
    Yang, Y
    Li, B
    ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1491 - 1495