Study on Short Time Charge Behavior in Pulsed Residual Charge Method for Water Tree Diagnostics of XLPE Cables

被引:0
|
作者
Futami, Hiroyuki [1 ]
Ra, Nhet [1 ]
Kawashima, Tomohiro [1 ]
Murakami, Yoshinobu [1 ]
Hozumi, Naohiro [1 ]
Kurihara, Takashi [2 ]
Okamoto, Tatsuki [2 ]
Miyajima, Kazuhisa [3 ]
Uchida, Katsumi [3 ]
机构
[1] Toyohashi Univ Technol, Toyohashi, Aichi, Japan
[2] Cent Res Inst Elect Power Ind, Tokyo, Japan
[3] Chubu Elect Power Co Inc, Nagoya, Aichi, Japan
关键词
water tree; residual charge method; XLPE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Water tree generated in insulation parts of the XLPE (Cross Linked Polyethylene) cable is concerned as one of the causes of deterioration or breakdown. For the stable supply of electric power, the facilitated and accurate diagnosis technique is important to measure the deterioration of power cable. In our previous study, we proposed a residual charge measurement method using pulse voltage (charge larder method) and suggested that this method makes it possible the degradation position to measure more accurately than conventional methods. In this method, the deterioration signal is detected when the charge trapped at the tip of water tree is depolarized by the short time pulse voltage. However, quantitative evaluations have not been studied yet. In this paper, we investigated the residual charge behavior around the water tree under pulse voltage application and performed the numerical analysis using Maxwell-Wagner model.
引用
收藏
页码:559 / 562
页数:4
相关论文
共 50 条
  • [31] Investigation of Applicability of Loss Current Method and Residual Charge Method to Bow-tie Tree - Measurement and Analysis for XLPE Sheet Sample-
    Kawahara T.
    Morita S.
    Fuse N.
    Kurihara T.
    Takahashi T.
    IEEJ Transactions on Fundamentals and Materials, 2022, 142 (08): : 354 - 361
  • [32] Study of the Space Charge Measurement Results on Two Kinds of Extruded XLPE Mini-cables
    Wang, Le
    Fabiani, Davide
    Montanari, Gian Carlo
    Nilsson, Ulf H.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 918 - +
  • [33] Time-resolved space charge observation in water-treed XLPE
    Mukai, S
    Ohki, Y
    Li, Y
    Maeno, T
    1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 645 - 648
  • [34] Correlation between space charge distribution and water-tree location in aged XLPE cable
    Suzuki, K
    Tanaka, Y
    Takada, T
    Ohki, Y
    Takeya, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (01) : 78 - 81
  • [35] Dynamic observation of space charge formation in XLPE using pulsed electro-acoustic method
    Takada, T
    Murata, K
    Tanaka, Y
    IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 161 - 164
  • [36] Three-dimensional space charge distribution in water tree tip using the pulsed electroacoustic method
    Li, Y
    Kawai, J
    Ebinuma, Y
    Imaizumi, Y
    Suzuki, K
    Tanaka, Y
    Takada, T
    ISE 9 - 9TH INTERNATIONAL SYMPOSIUM ON ELECTRETS, PROCEEDINGS, 1996, : 217 - 222
  • [37] Detection of Location and size of Water Tree in XLPE Cables by Frequency Response Analysis: A Simulation Study
    Hameed, Shahul K. M.
    Joseph, Jineeth
    Sindhu, T. K.
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 622 - 626
  • [38] Interface Polarization Characteristics of Water Tree Aged XLPE Cables Based on Polarization and Depolarization Current Method
    Yin Y.
    Zhou K.
    Li S.
    Chen Z.
    Zhang F.
    Zhou, Kai (zhoukai_scu@163.com), 1600, Chinese Machine Press (35): : 2643 - 2651
  • [39] Study on Artificial Water Tree Degradation Method for XLPE Power Cables (Part 2) - Proposal of Method for Water Tree Propagation under Continuous Heating and Heat Cycle Conditions-
    Kurihara T.
    Misaka H.
    Takahashi T.
    Takahashi T.
    IEEJ Transactions on Fundamentals and Materials, 2021, 141 (01) : 76 - 84
  • [40] Deterioration Analysis of Ex-Serviced 110 kV XLPE Cable Based on Residual Charge Method
    Du, B. X.
    Li, Hongbo
    Gao, Yu
    Wang, Li
    Huo, Zhenxing
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 638 - +