Study of the Mechanical Properties of NiTi Modified by Carbon Plasma Immersion Ion Implantation Using Nano-Indentation Test and Finite Element Method Simulation

被引:1
|
作者
Shanaghi, A. [1 ]
Siyavoshi, A. [1 ]
Souri, A. R. [1 ]
Shanaghi, Ab [2 ]
Chu, P. K. [3 ,4 ]
机构
[1] Malayer Univ, Fac Engn, Mat Engn Dept, Malayer, Iran
[2] Islamic Azad Univ, Fac Engn, Elect Engn Dept, Sci & Res Branch, Tehran, Iran
[3] City Univ Hong Kong, Dept Phys, Dept Mat Sci & Engn, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
[4] City Univ Hong Kong, Dept Biomed Engn, Kowloon, Tat Chee Ave, Hong Kong, Peoples R China
来源
PHYSICS OF METALS AND METALLOGRAPHY | 2022年 / 123卷 / 13期
关键词
carbon plasma immersion ion implantation; NiTi alloy; nano-mechanical properties; nano-indentation; finite element method; SURFACE MODIFICATION; BIOCOMPATIBILITY; CORROSION; TEMPERATURE; HARDNESS; ALLOYS;
D O I
10.1134/S0031918X21100574
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Plasma immersion ion implantation is one of the common methods to enhance the corrosion resistance, mechanical properties, and biological characteristics of NiTi alloys. Herein, the nano-mechanical behavior and distribution of compressive and tensile stress of NiTi alloy samples modified by carbon plasma immersion ion implantation (C-PIII) are analyzed by atomic force microscopy (AFM), nano-indentation test, and finite element method (FEM) simulation. C-PIII produces a modified layer with a thickness of 48 nm. The average surface roughness decreases from 34.023 to 25.180 nm and the hardness and Young's modulus increase to 80.7 and 21.8%, respectively, after C-PIII. FEM simulation reveals that elastic and plastic deformation similar to that observed experimentally arises from the increase in strength and changes in the surface phases stemming from C-PIII. The larger Young's modulus and hardness of the C-PIII sample reduces the penetration depth and plastic strain during nano-indentation resulting in a decrease of the compressive residual stress by 46% from -0.619 to -0.313 GPa at the tip of the indenter. Our results show that the durability and service lifetime of NiTi alloys can be improved by C-PIII thus boding well for biomedical applications in harsh environments such as blood vessel stents and bone joints.
引用
收藏
页码:1395 / 1401
页数:7
相关论文
共 50 条
  • [41] Plasma immersion ion implantation induced improvements of mechanical properties, wear resistance, and adhesion of diamond-like carbon films deposited on tool steel
    Chen, Kuan-Wei
    Lin, Jen-Fin
    Tsai, Wen-Fa
    Ai, Chi-Fong
    SURFACE & COATINGS TECHNOLOGY, 2009, 204 (03): : 229 - 236
  • [42] Predicting the mechanical properties of Cu-Al2O3 nanocomposites using machine learning and finite element simulation of indentation experiments
    Najjar, I. M. R.
    Sadoun, A. M.
    Alsoruji, Ghazi S.
    Abd Elaziz, Mohamed
    Wagih, A.
    CERAMICS INTERNATIONAL, 2022, 48 (06) : 7748 - 7758
  • [43] Study of plastically deformed region underneath the ball in indentation tests and evaluation of mechanical properties of materials through finite element simulation and a hybrid algorithm
    Samal, Mahendra K.
    Syed, A.
    Khatri, R. N.
    Chattopadhyay, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (01) : 108 - 121
  • [44] A Numerical Method for Microstructure Generation of a Binary Aluminum Alloy and Study of Its Mechanical Properties Using the Finite Element Method
    Sharifi, Hamid
    Larouche, Daniel
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2014, 45A (13): : 5866 - 5875
  • [45] A Numerical Method for Microstructure Generation of a Binary Aluminum Alloy and Study of Its Mechanical Properties Using the Finite Element Method
    Hamid Sharifi
    Daniel Larouche
    Metallurgical and Materials Transactions A, 2014, 45 : 5866 - 5875
  • [46] Ti-O/TiN films synthesized by plasma immersion ion implantation and deposition on 316L: Study of deformation behavior and mechanical properties
    Wan, GJ
    Huang, N
    Yang, P
    Leng, Y
    Sun, H
    Chen, JY
    Wang, J
    THIN SOLID FILMS, 2005, 484 (1-2) : 219 - 224
  • [47] Using molecular dynamics simulations and finite element method to study the mechanical properties of nanotube reinforced polyethylene and polyketone
    Rouhi, S.
    Alizadeh, Y.
    Ansari, R.
    Aryayi, M.
    MODERN PHYSICS LETTERS B, 2015, 29 (26):
  • [48] Structural, mechanical and hydrophobic properties of fluorine-doped diamond-like carbon films synthesized by plasma immersion ion implantation and deposition (PIII-D)
    Yao, ZQ
    Yang, P
    Huang, N
    Sun, H
    Wang, J
    APPLIED SURFACE SCIENCE, 2004, 230 (1-4) : 172 - 178
  • [49] The study of composition, structure, mechanical properties and platelet adhesion of Ti-O/TiN gradient films prepared by metal plasma immersion ion implantation and deposition
    Wen, F
    Huang, N
    Sun, H
    Wan, GJ
    Chu, PK
    Leng, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 222 (1-2): : 81 - 90
  • [50] Development of hybrid four-point bending test for determining mechanical properties of thin films using finite element method and response surface method
    Kinoshita, K.
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522