Artifact reduction in magnetogastrography using fast independent component analysis

被引:26
|
作者
Irimia, A [1 ]
Bradshaw, LA [1 ]
机构
[1] Vanderbilt Univ, Dept Phys & Astron, Living State Phys Grp, Nashville, TN 37235 USA
关键词
artifact reduction; magnetogastrography; independent component analysis;
D O I
10.1088/0967-3334/26/6/015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The analysis of magnetogastrographic (MGG) signals has been limited to epochs of data with limited interference from extraneous signal components that are often present and may even dominate MGG data. Such artifacts can be of both biological (cardiac, intestinal and muscular activities, motion artifacts, etc) and non-biological (environmental noise) origin. Conventional methods-such as Butterworth and Tchebyshev filters-can be of great use, but there are many disadvantages associated with them as well as with other typical filtering methods because a large amount of useful biological information can be lost, and there are many trade-offs between various filtering methods. Moreover, conventional filtering cannot always fully address the physicality of the signal-processing problem in terms of extracting specific signals due to particular biological sources of interest such as the stomach, heart and bowel. In this paper, we demonstrate the use of fast independent component analysis (FICA) for the removal of both biological and non-biological artifacts from multi-channel MGG recordings acquired using a superconducting quantum intereference device (SQUID) magnetometer. Specifically, we show that the signal of gastric electrical control activity (ECA) can be isolated from SQUID data as an independent component even in the presence of severe motion, cardiac and respiratory artifacts. The accuracy of the method is analyzed by comparing FICA-extracted versus electrode-measured respiratory signals. It is concluded that, with this method, reliable results may be obtained for a wide array of magnetic recording scenarios.
引用
收藏
页码:1059 / 1073
页数:15
相关论文
共 50 条
  • [31] Using independent component analysis to remove artifact from electroencephalographic measured during stuttered speech
    Y. Tran
    A. Craig
    P. Boord
    D. Craig
    Medical and Biological Engineering and Computing, 2004, 42 : 627 - 633
  • [32] Input reduction in human sensation modeling using independent component analysis
    Lee, KK
    Xu, YS
    IROS 2001: PROCEEDINGS OF THE 2001 IEEE/RJS INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4: EXPANDING THE SOCIETAL ROLE OF ROBOTICS IN THE NEXT MILLENNIUM, 2001, : 1854 - 1859
  • [33] Dimension reduction of process dynamic trends using independent component analysis
    Li, RF
    Wang, XZ
    COMPUTERS & CHEMICAL ENGINEERING, 2002, 26 (03) : 467 - 473
  • [34] Fast kernel density independent component analysis
    Chen, AY
    INDEPENDENT COMPONENT ANALYSIS AND BLIND SIGNAL SEPARATION, PROCEEDINGS, 2006, 3889 : 24 - 31
  • [35] EEG Artifact Removal Based on Independent Component Analysis and Outlier Detection
    Wang, Xinxin
    Wang, Xiuwei
    Zhou, Biao
    2022 14TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS AND SIGNAL PROCESSING, WCSP, 2022, : 209 - 214
  • [36] Enhanced Automatic Wavelet Independent Component Analysis for Electroencephalographic Artifact Removal
    Mammone, Nadia
    Morabito, Francesco C.
    ENTROPY, 2014, 16 (12) : 6553 - 6572
  • [37] The Removal of Blink and Saccade Artifact in EEG recordings by Independent Component Analysis
    Dong, Jie
    Wang, Tao
    Zhang, Ai-tao
    Dai, Hong-ya
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1071 - 1075
  • [38] Spatially constrained independent component analysis for artifact correction in EEG and MEG
    Ille, N
    Beucker, R
    Scherg, M
    NEUROIMAGE, 2001, 13 (06) : S159 - S159
  • [39] An independent component ballistocardiogram analysis-based approach on artifact removing
    Briselli, Ennio
    Garreffa, Girolamo
    Bianchi, Luigi
    Bianciardi, Marta
    Macaluso, Emiliano
    Abbafati, Manuel
    Marcianibe, Maria Grazia
    Maraviglia, Bruno
    MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 393 - 400
  • [40] Combination of Independent Vector Analysis and Improved Fast Independent Component Analysis for Speckle Noise Reduction in Synthetic Aperture Radar Images
    Liu, Xianglei
    Wang, Yutong
    Wang, Runjie
    Adil, Nilufar
    Sensors and Materials, 2024, 36 (12) : 5377 - 5393