Electrochemical behavior and determination of rutin on a pyridinium-based ionic liquid modified carbon paste electrode

被引:88
|
作者
Sun, Wei [1 ]
Yang, Maoxia [1 ]
Li, Yinzhuo [1 ]
Jiang, Qiang [1 ]
Liu, Shufeng [1 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Minist Educ, Key Lab Ecochem Engn, Qingdao 266042, Peoples R China
基金
美国国家科学基金会;
关键词
Ionic liquid; Carbon paste electrode; Rutin; Cyclic voltammetry; Electrochemistry;
D O I
10.1016/j.jpba.2008.09.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper the electrochemical behavior of rutin on a pyridinium-typed ionic liquid modified carbon paste electrode (IL-CPE) was investigated and further used for rutin sample determination. The IL-CPE showed strong electrocatalytic effects to the oxidation of rutin. In phosphate buffer solution (PBS, pH 2.5; 0.1 M) a pair of well-defined cyclic voltammetric redox peaks of rutin appeared with the redox peak located at 512 mV (Epa) and 448 mV (Epc) (vs. SCE), respectively. The redox peak current was increased about 27.5 times more than that on traditional carbon paste electrode (CPE). The electrochemical parameters of rutin on the IL-CPE were calculated with the results of the charge transfer coefficient (alpha), the number of electron transfer (n) and the electrode reaction rate constant (k(s)) as 0.53, 1.80 and 2.39 s(-1), respectively. The cathodic peak currents increased linearly with the concentration of rutin in the range from 5.0 x 10(-7) to 1.0 x 10(-4) M with the detection limit as 3.58 x 10(-7) M (3 alpha). The relative standard deviation (RSD) of 10 successive detection of 5.0 x 10(-5) M rutin was 4.2%. The method was successfully applied to the determination of rutin content in tablets samples with good recovery. The modified electrode showed good stability and reproducibility without the influence of the coexisting substances. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1326 / 1331
页数:6
相关论文
共 50 条
  • [21] Electrochemical detection of rutin with a carbon ionic liquid electrode modified by Nafion, graphene oxide and ionic liquid composite
    Hu, Song
    Zhu, Huanhuan
    Liu, Shengyun
    Xiang, Jun
    Sun, Wei
    Zhang, Liqi
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 211 - 219
  • [22] Electrochemical detection of rutin with a carbon ionic liquid electrode modified by Nafion, graphene oxide and ionic liquid composite
    Song Hu
    Huanhuan Zhu
    Shengyun Liu
    Jun Xiang
    Wei Sun
    Liqi Zhang
    Microchimica Acta, 2012, 178 : 211 - 219
  • [23] Electrochemical behavior of rutin on a multi-walled carbon nanotube and ionic liquid composite film modified electrode
    Liu, Xiuhui
    Li, Li
    Zhao, Xueping
    Lu, Xiaoquan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 81 (01) : 344 - 349
  • [24] Electrochemical behaviors and determination of carbidopa on carbon nanotubes ionic liquid paste electrode
    Beitollah, Hadis
    Goodarzian, Maryam
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    Hassanzadeh, Marjan
    Tajbakhsh, Mahgol
    JOURNAL OF MOLECULAR LIQUIDS, 2012, 173 : 137 - 143
  • [25] Electrochemical Behaviors of Methocarbamol at an Acetylene Black-Ionic Liquid Modified Carbon Paste Electrode and its Electrochemical Determination
    Zhang, Yan-Mei
    You, Wei
    Gao, Zuo-Ning
    Yang, Tian-Lin
    CROATICA CHEMICA ACTA, 2013, 86 (03) : 309 - 315
  • [26] Electrochemical Determination of Rutin on a Gold Microsphere-Taro Stalk Porous Carbon Modified Carbon Ionic Liquid Electrode (CILE)
    Chen, Yuxue
    Weng, Wenju
    Jiao, Guosong
    Cheng, Hui
    Niu, Yanyan
    Li, Guangjiu
    Sun, Wei
    ANALYTICAL LETTERS, 2024, 57 (11) : 1765 - 1777
  • [27] Highly sensitive electrochemical sensor based on pyrrolidinium ionic liquid modified ordered mesoporous carbon paste electrode for determination of carbendazim
    Ya, Yu
    Wang, Tianshun
    Xie, Liping
    Zhu, Junjie
    Tang, Li
    Ning, Dejiao
    Yan, Feiyan
    ANALYTICAL METHODS, 2015, 7 (04) : 1493 - 1498
  • [28] Electrochemical Behaviors and Sensitive Determination of Guanosine-5′-monophosphate on Ionic Liquid Modified Carbon Paste Electrode
    Sun, Wei
    Xu, Li
    Liu, Jun
    Wang, Xiuzhen
    Hu, Song
    Xiang, Jun
    CROATICA CHEMICA ACTA, 2013, 86 (02) : 129 - 135
  • [29] Electrochemical Determination of Tert-butylhydroxyanisole uses Carbon Paste Electrode Modified with Ionic Liquid and CdO Nanoparticle
    Asari-Bami, Hesam
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (08): : 1033 - 1043
  • [30] Electrochemical behavior and determination of guanosine-5′-monophosphate on a ionic liquid modified carbon electrode
    Fan Shi
    Xiuzhen Wang
    Wencheng Wang
    Wei Sun
    Journal of Analytical Chemistry, 2015, 70 : 186 - 192