Sag-Tension Calculation Program for Wood Pole Overhead Lines

被引:0
|
作者
Baker, Catherine [1 ]
Baker, John
Nouri, Hassan [1 ,2 ]
机构
[1] Univ W England, Power Syst & Elect Res Lab, Bristol BS16 1QY, Avon, England
[2] Univ West England, Power Syst & Elect Res Lab, Bristol, Avon, England
关键词
Clearance; Conductor; Overhead Line; PLS-CADD; Sag; Tension;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents studies into a new program used to calculate sag and tension of conductors on wood pole lines considering all relevant parameters, such as conductor temperature, wind and ice loadings and creep. Based on this information and data provided by the user, the program also provides information on clearances and structural loadings. Furthermore, the paper describes expressions used to develop the program. The program is in a Microsoft Excel domain for ease of use by SSE planners for whom the program has been developed and is found to provide more information than readily available programs on the market. A set of data is obtained experimentally at the Scottish and Southern Energy (SSE) overhead line training school using a 58 metre span of 50 millimetre Hazel conductor (all aluminium alloy conductor) strung at various tensions between two wood poles at an air temperature of 2.5 degrees Celsius. This data is used to validate the data from the new program. Attentive analysis
引用
收藏
页数:6
相关论文
共 50 条
  • [21] EXPERIMENTAL-VERIFICATION OF A REAL-TIME PROGRAM FOR THE DETERMINATION OF TEMPERATURE AND SAG OF OVERHEAD LINES
    BUSH, RA
    BLACK, WZ
    CHAMPION, TC
    BYRD, WR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 2284 - 2288
  • [22] Contactless sag detection on overhead lines by image processing
    Glass, Martin
    Veit, Florian
    Derbel, Faouzi
    TM-TECHNISCHES MESSEN, 2021, 88 (11) : 696 - 701
  • [23] Effect of wind turbine wakes on wind-induced motions in wood-pole overhead lines
    MacIver, C.
    Cruden, A.
    Leithead, W. E.
    Bertinat, M. P.
    WIND ENERGY, 2015, 18 (04) : 643 - 662
  • [24] Sag Calculation Difference Caused by Temperature Difference between the Steel Core and Outer Surface of Overhead Transmission Lines
    Liu, Gang
    Li, Yang
    Qi, Kunlun
    Yu, Jinyu
    Cai, Yiming
    PROCEEDINGS OF THE 2016 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2016,
  • [25] Calculation of Induced EMF by Overhead Lines
    Korovkin, Nikolay
    Goncharov, Valeriy
    PROCEEDINGS OF THE 2016 IEEE NORTH WEST RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (ELCONRUSNW), 2016, : 608 - 610
  • [26] Effect of Radial Temperature Difference on Sag Calculation for Overhead Conductors
    Liu, Gang
    Li, Yang
    Chen, Yuan
    Yang, Yu-Hang
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2017, 45 (07): : 41 - 47
  • [27] Sag Monitoring of Overhead Power Lines based on Image Processing
    Abed, Achref
    Glass, Martin
    Trabelsi, Hafedh
    Derbel, Faouzi
    2021 18TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2021, : 142 - 146
  • [28] The Influence of Tower Foundation Settlement on the Sag and Stress of Overhead Lines
    Wang Zhang-qi
    Jiang Wen-qiang
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 2, PROCEEDINGS, 2009, : 340 - 343
  • [29] Sag and Tension Calculations for High-Voltage Overhead Line Conductors
    Kampik, Marian
    Kubek, Pawel
    Krupanek, Beata
    Bogacz, Ryszard
    ENERGIES, 2024, 17 (12)
  • [30] Tension and Ampacity Monitoring System for Overhead Lines
    Albizu, Igor
    Fernandez, Elvira
    Eguia, Pablo
    Torres, Esther
    Javier Mazon, Angel
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) : 3 - 10