Study on High-intensity Focused Ultrasound Focal Position Control Using Intracorporeal Acoustic Device

被引:4
|
作者
Harada, Kanako [1 ]
Azuma, Takashi [1 ]
Inoue, Tomoyuki [1 ]
Takeo, Toshiaki [1 ]
Takagi, Shu [1 ]
Matsumoto, Yoichiro [1 ]
Sugita, Naohiko [1 ]
Mitsuishi, Mamoru [1 ]
机构
[1] Univ Tokyo, Bunkyo Ku, Tokyo 1138656, Japan
关键词
high-intensity focused ultrasound; medical device; surgical robotic device;
D O I
10.1016/j.procir.2013.01.057
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High-intensity focused ultrasound (HIFU) is widely used in cancer therapies, and it is hoped that its noninvasiveness will allow it to be applied to other clinical domains. Because HIFU is percutaneously delivered in the treatment of the liver, breast and uterus, there is a problem with the ultrasound beam being deflected or attenuated during its travel. In contrast, the intracorporeal use of an HIFU device provides an obstacle-free path, but the focal length is limited because of size constraints. In this paper, we propose the use of an intracorporeal device equipped with an acoustic mirror or lens to allow the ultrasound energy delivered through the abdominal wall to be reflected or focused in the body. The insertion of such a device into the body requires a small incision, but the proposed concept can help to safely control the HIFU focal point in the treatment of deep-seated organs. Moreover, safety is ensured because the device is electrically isolated. We have developed an experimental setup where the intracorporeal device is robotically positioned in front of an HIFU transducer. In preliminary experiments, the focused ultrasound energy was reflected using a metal plate, and the planar ultrasound waves were focused using an acrylic biconcave lens, with Schlieren imaging used for visualisation, and the results demonstrated the proof of concept. (C) 2013 The Authors. Published by Elsevier B.V. Selection and/or peer-review under responsibility of Professor Mamoru Mitsuishi and Professor Paulo Bartolo
引用
收藏
页码:290 / 293
页数:4
相关论文
共 50 条
  • [41] Robot-Assisted High-Intensity Focused Ultrasound in Focal Therapy of Prostate Cancer
    Chaussy, Christian G.
    Thueroff, Stefan
    JOURNAL OF ENDOUROLOGY, 2010, 24 (05) : 843 - 847
  • [42] Histotripsy: The Next Generation of High-Intensity Focused Ultrasound for Focal Prostate Cancer Therapy
    Dubinsky, Theodore J.
    Khokhlova, Tanya D.
    Khokhlova, Vera
    Schade, George A.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (06) : 1057 - 1067
  • [43] Dynamics and control of cavitation during high-intensity focused ultrasound application
    Thomas, CR
    Farny, CH
    Coussios, CC
    Roy, RA
    Holt, RG
    ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2005, 6 (03): : 182 - 187
  • [44] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    VALTOT, F
    KOPEL, J
    HAUT, J
    INTERNATIONAL OPHTHALMOLOGY, 1989, 13 (1-2) : 167 - 170
  • [45] An early history of high-intensity focused ultrasound
    O'Brien, William D., Jr.
    Dunn, Floyd
    PHYSICS TODAY, 2015, 68 (10) : 40 - 45
  • [46] A Review of High-Intensity Focused Ultrasound in Urology
    Cranston, David
    Leslie, Tom
    ter Haar, Gail
    CANCERS, 2021, 13 (22)
  • [47] High-Intensity Focused Ultrasound in Functional Neurosurgery
    Tyurnikov V.M.
    Gushcha A.O.
    Human Physiology, 2017, 43 (8) : 916 - 921
  • [48] High-intensity focused ultrasound for prostate cancer
    Napoli, Alessandro
    Alfieri, Giulia
    Scipione, Roberto
    Leonardi, Andrea
    Fierro, Davide
    Panebianco, Valeria
    De Nunzio, Cosimo
    Leonardo, Costantino
    Catalano, Carlo
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 427 - 433
  • [49] High-intensity Focused Ultrasound: Ready for Primetime
    Rove, Kyle O.
    Sullivan, Kathryn F.
    Crawford, E. David
    UROLOGIC CLINICS OF NORTH AMERICA, 2010, 37 (01) : 27 - +
  • [50] Is high-intensity focused ultrasound therapy option?
    Weiss, Johannes
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2014, 52 (05):