Comparing neural response to painful electrical stimulation with functional MRI at 3 and 7 T

被引:41
|
作者
Hahn, Andreas [1 ]
Kranz, Georg S. [1 ]
Seidel, Eva-Maria [2 ]
Sladky, Ronald [3 ]
Kraus, Christoph [1 ]
Kueblboeck, Martin [3 ]
Pfabigan, Daniela M. [2 ]
Hummer, Allan [3 ]
Grahl, Arvina [2 ]
Ganger, Sebastian [1 ]
Windischberger, Christian [3 ]
Lamm, Claus [2 ]
Lanzenberger, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Psychiat & Psychotherapy, A-1090 Vienna, Austria
[2] Univ Vienna, Fac Psychol, Social Cognit & Affect Neurosci Unit, A-1010 Vienna, Austria
[3] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
关键词
fMRI; Pain stimulation; 7T; 3T; HUMAN AMYGDALA; BRAIN-STEM; PHYSIOLOGICAL NOISE; FMRI; FIELD; ACQUISITION; MODULATION; ACTIVATION; ANALGESIA; ECHO;
D O I
10.1016/j.neuroimage.2013.06.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Progressing from 3 T to 7 T functional MRI enables marked improvements of human brain imaging in vivo. Although direct comparisons demonstrated advantages concerning blood oxygen level dependent (BOLD) signal response and spatial specificity, these mostly focused on single brain regions with rather simple tasks. Considering that physiological noise also increases with higher field strength, it is not entirely clear whether the advantages of 7 T translate equally to the entire brain during tasks which elicit more complex neuronal processing. Therefore, we investigated the difference between 3 T and 7 Tin response to transcutaneous electrical painful and non-painful stimulation in 22 healthy subjects. For painful stimuli vs. baseline, stronger activations were observed at 7 Tin several brain regions including the insula and supplementary motor area, but not the secondary somatosensory cortex (p < 0.05 FWE-corrected). Contrasting painful vs. non-painful stimulation limited the differences between the field strengths to the periaqueductal gray (PAG, p < 0.001 uncorrected) due to a similar signal increase at 7 T for both the target and specific control condition in most brain regions. This regional specificity obtained for the PAG at higher field strengths was confirmed by an additional spatial normalization strategy optimized for the brainstem. Here, robust BOLD responses were obtained in the dorsal PAG at 7 T (p < 0.05 FWE-corrected), whereas at 3 T activation was completely missing for the contrast against non-painful stimuli. To summarize, our findings support previously reported benefits obtained at ultra-high field strengths also for complex activation patterns elicited by painful electrical stimulation. However, this advantage depends on the region and even more on the contrast of interest The greatest gain at 7 T was observed within the small brainstem region of the PAG, where the increased field strength offered marked improvement for the localization of activation foci with high spatial specificity. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:336 / 343
页数:8
相关论文
共 50 条
  • [31] Comparing 3DQRS and VCG approaches for ECG QRS detection within 1.5T, 3T and 7T MRI
    Thomas S Gregory
    Ehud J Schmidt
    Shelley H Zhang
    Zion T Tse
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [32] Influence of Repetitive Transcranial Magnetic Stimulation on Human Neurochemistry and Functional Connectivity: A Pilot MRI/MRS Study at 7 T
    Grohn, Heidi
    Gillick, Bernadette T.
    Tkac, Ivan
    Bednarik, Petr
    Mascali, Daniele
    Deelchand, Dinesh K.
    Michaeli, Shalom
    Meekins, Gregg D.
    Leffler-McCabe, Michael J.
    MacKinnon, Colum D.
    Eberly, Lynn E.
    Mangia, Silvia
    FRONTIERS IN NEUROSCIENCE, 2019, 13
  • [33] Age-related reduction in functional MRI response to photic stimulation
    Ross, MH
    YurgelunTodd, DA
    Renshaw, PF
    Maas, LC
    Mendelson, JH
    Mello, NK
    Cohen, BM
    Levin, JM
    NEUROLOGY, 1997, 48 (01) : 173 - 176
  • [34] Functional MRI detection of hemodynamic response of repeated median nerve stimulation
    Ai, Leo
    Oya, Hiroyuki
    Howard, Matthew
    Xiong, Jinhu
    MAGNETIC RESONANCE IMAGING, 2013, 31 (04) : 550 - 554
  • [35] International Functional Electrical Stimulation Society (IFESS): the development of controlled neural prostheses for functional restoration
    Davis, R
    NEUROMODULATION, 2000, 3 (01): : 1 - 5
  • [36] Recovery of Actual Functional Tasks in Response to Motor Learning, Robotics, and Functional Electrical Stimulation
    Daly, Janis J.
    Rogers, Jean
    McCabe, Jessica
    Monkiewicz, Michelle
    Burdsall, Richard
    Pundik, Svetlana
    STROKE, 2010, 41 (04) : E355 - E356
  • [37] Functional Electrical Stimulation for control of internal organ function - Author response
    不详
    NEUROMODULATION, 2001, 4 (04): : 162 - 162
  • [38] Dual Neural Network Control of a Hybrid Functional Electrical Stimulation Cycling System
    Merritt, Glen R.
    Akbari, Saiedeh
    Cousin, Christian A.
    Yoon, Hwan-Sik
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2023, 145 (12):
  • [39] Neural network control for leg rhythmic movements via functional electrical stimulation
    Zhang, DG
    Zhu, KY
    2004 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-4, PROCEEDINGS, 2004, : 1245 - 1248
  • [40] Neural correlates of emotional self in bipolar disorder: a BOLD functional MRI 3T study
    Radaelli, D.
    Benedetti, F.
    Bernasconi, A.
    Blasi, V.
    Cadioli, M.
    Colombo, C.
    Dallaspezia, S.
    Falini, A.
    Scotti, G.
    Smeraldi, E.
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2006, 16 : S270 - S271