Comparison of two-dimensional and three-dimensional iterative watershed segmentation methods in hepatic tumor volumetrics

被引:16
|
作者
Ray, Shonket [1 ,2 ]
Hagge, Rosalie [2 ]
Gillen, Marijo [2 ]
Cerejo, Miguel [2 ]
Shakeri, Shidrokh [2 ]
Beckett, Laurel [3 ]
Greasby, Tamara [3 ]
Badawi, Ramsey D. [1 ,2 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Div Biostat, Dept Publ Hlth Sci, Davis, CA 95616 USA
关键词
biomedical measurement; cancer; computerised tomography; fuzzy set theory; gradient methods; image segmentation; liver; medical image processing; phantoms; positron emission tomography; tumours; volume measurement;
D O I
10.1118/1.3013561
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work the authors compare the accuracy of two-dimensional (2D) and three-dimensional (3D) implementations of a computer-aided image segmentation method to that of physician observers (using manual outlining) for volume measurements of liver tumors visualized with diagnostic contrast-enhanced and PET/CT-based non-contrast-enhanced (PET-CT) CT scans. The method assessed is a hybridization of the watershed method using observer-set markers with a gradient vector flow approach. This method is known as the iterative watershed segmentation (IWS) method. Initial assessments are performed using software phantoms that model a range of tumor shapes, noise levels, and noise qualities. IWS is then applied to CT image sets of patients with identified hepatic tumors and compared to the physicians' manual outlines on the same tumors. The repeatability of the physicians' measurements is also assessed. IWS utilizes multiple levels of segmentation performed with the use of "fuzzy regions" that could be considered part of a selected tumor. In phantom studies, the outermost volume outline for level 1 (called level 1_1 consisting of inner region plus fuzzy region) was generally the most accurate. For in vivo studies, the level 1_1 and the second outermost outline for level 2 (called level 2_2 consisting of inner region plus two fuzzy regions) typically had the smallest percent error values when compared to physician observer volume estimates. Our data indicate that allowing the operator to choose the "best result" level iteration outline from all generated outlines would likely give the more accurate volume for a given tumor rather than automatically choosing a particular level iteration outline. The preliminary in vivo results indicate that 2D-IWS is likely to be more accurate than 3D-IWS in relation to the observer volume estimates.
引用
收藏
页码:5869 / 5881
页数:13
相关论文
共 50 条
  • [21] Three-dimensional solutions for two-dimensional problems
    Shen, A
    MATHEMATICAL INTELLIGENCER, 1997, 19 (03): : 44 - 47
  • [22] Licata: Two-dimensional and three-dimensional art
    Cristiani, MLT
    CRITICA D ARTE, 2002, 65 (16): : 19 - 20
  • [23] Two-Dimensional Modeling of Three-Dimensional Waves
    Chalikov, D.
    OCEANOLOGY, 2021, 61 (06) : 850 - 860
  • [24] Two-Dimensional Modeling of Three-Dimensional Waves
    D. Chalikov
    Oceanology, 2021, 61 : 850 - 860
  • [25] Two-dimensional turbulence in three-dimensional flows
    Xia, H.
    Francois, N.
    PHYSICS OF FLUIDS, 2017, 29 (11)
  • [26] Natural position of the head: review of two-dimensional and three-dimensional methods of recording
    Cassi, D.
    De Biase, C.
    Tonni, I.
    Gandolfini, M.
    Di Blasio, A.
    Piancino, M. G.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (03): : 233 - 240
  • [27] Radiotherapy for nasopharyngeal carcinoma - transition from two-dimensional to three-dimensional methods
    Teo, PML
    Ma, BBY
    Chan, ATC
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 (02) : 163 - 172
  • [28] Limitations of the two-dimensional and three-dimensional proximal isovelocity surface area methods
    Tsarpalis, Konstantinos
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (09): : 1495 - 1496
  • [29] Three-dimensional ultrasonography of normal fetal heart: Comparison with two-dimensional imaging
    Department of Radiology, McGill University, Jewish General Hospital, Montreal, Que., Canada
    不详
    不详
    不详
    不详
    J. Ultrasound Med., 6 (341-348):
  • [30] Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery
    A. C. W. Chan
    S. C. S. Chung
    A. P. C. Yim
    J. Y. W. Lau
    E. K. W. Ng
    A. K. C. Li
    Surgical Endoscopy, 1997, 11 : 438 - 440