Displacement to separate host-cell proteins and aggregates in cation-exchange chromatography of monoclonal antibodies

被引:14
|
作者
Khanal, Ohnmar [1 ]
Kumar, Vijesh [1 ]
Lenhoff, Abraham M. [1 ]
机构
[1] Univ Delaware, Dept Chem & Biomol Engn, Newark, DE 19716 USA
关键词
aggregates; continuous chromatography; displacement; frontal chromatography; host-cell proteins; multicolumn chromatography; REVERSIBLE SELF-ASSOCIATION; FLOW-THROUGH PURIFICATION; ION-EXCHANGE; IDENTIFICATION; IMPURITIES; VARIANTS; PRODUCT; MONOMER; DESIGN; DIMER;
D O I
10.1002/bit.27559
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An efficient and consistent method of monoclonal antibody (mAb) purification can improve process productivity and product consistency. Although protein A chromatography removes most host-cell proteins (HCPs), mAb aggregates and the remaining HCPs are challenging to remove in a typical bind-and-elute cation-exchange chromatography (CEX) polishing step. A variant of the bind-and-elute mode is the displacement mode, which allows strongly binding impurities to be preferentially retained and significantly improves resin utilization. Improved resin utilization renders displacement chromatography particularly suitable in continuous chromatography operations. In this study we demonstrate and exploit sample displacement between a mAb and impurities present at low prevalence (0.002%-1.4%) using different multicolumn designs and recycling. Aggregate displacement depends on the residence time, sample concentration, and solution environment, the latter by enhancing the differences between the binding affinities of the product and the impurities. Displacement among the mAb and low-prevalence HCPs resulted in an effectively bimodal-like distribution of HCPs along the length of a multi-column system, with the mAb separating the relatively more basic group of HCPs from those that are more acidic. Our findings demonstrate that displacement of low-prevalence impurities along multiple CEX columns allows for selective separation of mAb aggregates and HCPs that persist through protein A chromatography.
引用
收藏
页码:164 / 174
页数:11
相关论文
共 50 条
  • [21] ION SELECTIVITY IN THE HIGH-PERFORMANCE CATION-EXCHANGE CHROMATOGRAPHY OF PROTEINS
    GOODING, KM
    SCHMUCK, MN
    JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL): : 321 - 328
  • [22] Identification and characterization of CHO host-cell proteins in monoclonal antibody bioprocessing
    Oh, Young Hoon
    Mendola, Kerri M.
    Choe, Leila H.
    Min, Lie
    Lavoie, Ashton R.
    Sripada, Sobhana A.
    Williams, Taufika Islam
    Lee, Kelvin H.
    Yigzaw, Yinges
    Seay, Alexander
    Bill, Jerome
    Li, Xuanwen
    Roush, David J.
    Cramer, Steven M.
    Menegatti, Stefano
    Lenhoff, Abraham M.
    BIOTECHNOLOGY AND BIOENGINEERING, 2024, 121 (01) : 291 - 305
  • [23] Purification of monoclonal antibodies from cell culture supernatants using a modified zirconia based cation-exchange support
    Clausen, AM
    Subramanian, A
    Carr, PW
    JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (01) : 63 - 72
  • [24] Development of poly(methacrylate)-grafted Sepharose FF for cation-exchange chromatography of proteins
    Li, Xianxiu
    Liu, Yang
    Sun, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1634
  • [25] DECREASE IN TIME REQUIRES TO SEPARATE COMPLEX BIOCHEMICAL MIXTURES BY COUPLED ANION-EXCHANGE AND CATION-EXCHANGE CHROMATOGRAPHY
    SCOTT, CD
    CHILCOTE, DD
    CLINICAL CHEMISTRY, 1971, 17 (07) : 650 - &
  • [26] CATION-EXCHANGE CHROMATOGRAPHY APPLIED TO THE STUDY OF DIVALENT-CATIONS BOUND TO PROTEINS
    ALDA, O
    ESCANERO, JF
    IRCS MEDICAL SCIENCE-BIOCHEMISTRY, 1982, 10 (12): : 946 - 946
  • [27] Weak cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins
    Chen, Xin
    Tolley, H. Dennis
    Lee, Milton L.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (16-17) : 2063 - 2071
  • [28] Protein concentration and analyzing charge variants in a co-formulation comprising three monoclonal antibodies: A cation-exchange chromatography approach
    Liu, Anyuan
    Liang, Tiantian
    Wu, Weiliang
    Weng, Jingwen
    Wu, Hongbing
    Zhou, Fangyuan
    Guo, Jeremy
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2025, 670
  • [29] pH-based cation exchange chromatography in the capture and elution of monoclonal antibodies
    Ng, Paul K.
    Snyder, Mark A.
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (01) : 29 - 35
  • [30] Polymeric strong cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins
    Chen, Xin
    Tolley, H. Dennis
    Lee, Milton L.
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) : 2565 - 2573