Long-term Intravascular Blood-Pressure Monitoring with a Novel, Wireless Sensor System - Results from Chronic In-vivo Studies

被引:0
|
作者
Cleven, Nina [1 ]
Woitok, Anna [2 ]
Isfort, Peter [2 ]
Penzkofer, Tobias [2 ]
Goertz, Michael [3 ]
Goettsche, Thorsten [4 ]
Steinseifer, Ulrich [5 ]
Schmitz-Rode, Thomas [6 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst, Inst Appl Med Engn, Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp, Aachen, Germany
[3] Fraunhofer Inst Microelect Circuits & Syst, Duisburg, Germany
[4] Osypka AG, Rheinfelden, Germany
[5] Helmholtz Inst, Dept Cardiovasc Engn, Aachen, Germany
[6] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Aachen, Germany
关键词
D O I
10.1016/j.jacc.2012.08.122
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:B33 / B33
页数:1
相关论文
共 50 条
  • [31] POST-OPERATIVE BLOOD-PRESSURE IN COARCTATION OF THE AORTA - LONG-TERM RESULTS IN 250 PATIENTS
    KUHN, H
    TILMANN, B
    BIRCKS, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1979, 68 (05): : 326 - 334
  • [32] BLOOD-PRESSURE AND SLEEP-APNEA - RESULTS OF LONG-TERM NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY
    MAYER, J
    BECKER, H
    BRANDENBURG, U
    PENZEL, T
    PETER, JH
    VONWICHERT, P
    CARDIOLOGY, 1991, 79 (02) : 84 - 92
  • [33] A TELE-EMERGENT SYSTEM FOR LONG-TERM ECG MONITORING OVER WIRELESS SENSOR NETWORK
    Hsiao, C. C.
    Lee, R. G.
    Chou, I. C.
    Lin, C. C.
    Huang, D. Y.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (03): : 187 - 197
  • [34] A tele-emergent system for long-term ECG monitoring over wireless sensor network
    Hsiao, C.C.
    Lee, R.G.
    Chou, I.C.
    Lin, C.C.
    Huang, D.Y.
    Biomedical Engineering - Applications, Basis and Communications, 2007, 19 (03) : 187 - 197
  • [35] The Design of Densely Measured Points Long-term Monitoring System Based on Wireless Sensor Network
    Cheng, Xiang
    Liu, Zhanhui
    Gao, Weicheng
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1123 - 1127
  • [36] LONG-TERM AMBULATORY MONITORING OF INDIRECT ARTERIAL BLOOD-PRESSURE USING A VOLUME-OSCILLOMETRIC METHOD
    YAMAKOSHI, K
    KAWARADA, A
    KAMIYA, A
    SHIMAZU, H
    ITO, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (05) : 459 - 465
  • [37] Long-term safety and performance of a novel conical bioresorbable vascular scaffold: insights from in-vitro and in-vivo studies
    Ma, Q.
    Du, Y.
    Wang, J. L.
    Wu, S. J.
    Zhao, Y. X.
    Zhou, Y. J.
    EUROPEAN HEART JOURNAL, 2020, 41 : 2538 - 2538
  • [38] PERCUTANEOUS TRANS-LUMINAL RENAL ANGIOPLASTY - INFLUENCE OF COMPLICATIONS ON LONG-TERM BLOOD-PRESSURE RESULTS
    ROSSI, GP
    FELTRIN, GP
    MIOTTO, D
    SEMPLICINI, A
    CASOLINO, P
    MOZZATO, MG
    PESSINA, AC
    JOURNAL OF HYPERTENSION, 1985, 3 : S461 - S463
  • [39] DIURNAL MONITORING OF BLOOD-PRESSURE AND THE RENIN-ANGIOTENSIN SYSTEM IN HYPERTENSIVE PATIENTS ON LONG-TERM ANGIOTENSIN CONVERTING ENZYME-INHIBITION
    GADSBOLL, N
    NIELSEN, MD
    GIESE, J
    LETH, A
    LONBORGJENSEN, H
    JOURNAL OF HYPERTENSION, 1990, 8 (08) : 733 - 740