Simultaneous neutron transmission and diffraction contrast tomography as a non-destructive 3D method for bulk single crystal quality investigations

被引:22
|
作者
Peetermans, S. [1 ,2 ]
Lehmann, E. H. [1 ]
机构
[1] Paul Scherrer Inst, Neutron Imaging & Activat Grp, CH-5232 Villigen, Switzerland
[2] Ecole Polytech Fed Lausanne, NXMM Lab, IMX, CH-1015 Lausanne, Switzerland
关键词
TOPOGRAPHY;
D O I
10.1063/1.4823741
中图分类号
O59 [应用物理学];
学科分类号
摘要
Traditional neutron tomography allows to reconstruct the attenuation cross section, a measure for the material distribution, at high spatial resolution and non-destructively. However, it does not state anything about the ordering structure of the atoms inside this material. Extending the setup with a second neutron imaging detector, diffracted neutrons from the ordered crystal lattice could be captured. Emerging iterative reconstruction techniques allow reconstructing the local Bragg reflectivity in the sample, a measure for the spatial distribution in crystal quality (orientation, homogeneity of phases). Simultaneous acquisition ensures optimal use of the neutron flux and a direct comparison of different sample properties. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced composites
    Hanhan, Imad
    Agyei, Ronald
    Xiao, Xianghui
    Sangid, Michael D.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2019, 184
  • [32] A simultaneous non-destructive characterisation method for grain size and single-crystal elastic constants of cubic polycrystals from ultrasonic measurements
    Sha, Gaofeng
    INSIGHT, 2018, 60 (04) : 190 - 193
  • [33] Modification of the Grid-Characteristic Method on Chimera Meshes for 3D Problems of Railway Non-destructive Testing
    Kozhemyachenko A.
    Favorskaya A.
    Pesnya E.
    Stetsyuk V.
    Lobachevskii Journal of Mathematics, 2023, 44 (1) : 376 - 386
  • [34] On-line monitoring of oxygen as a non-destructive method to quantify cells in engineered 3D tissue constructs
    Santoro, R.
    Krause, C.
    Martin, I.
    Wendt, D.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 (09) : 696 - 701
  • [35] A precise and non-destructive method to calculate the surface area in living scleractinian corals using X-ray computed tomography and 3D modeling
    Laforsch, C.
    Christoph, E.
    Glaser, C.
    Naumann, M.
    Wild, C.
    Niggl, W.
    CORAL REEFS, 2008, 27 (04) : 811 - 820
  • [36] A precise and non-destructive method to calculate the surface area in living scleractinian corals using X-ray computed tomography and 3D modeling
    C. Laforsch
    E. Christoph
    C. Glaser
    M. Naumann
    C. Wild
    W. Niggl
    Coral Reefs, 2008, 27 : 811 - 820
  • [37] Non-destructive micro analysis of electromigration failures in solder microbumps using 3D X-ray computed tomography
    Tran, Dinh-Phuc
    Lin, Tzu-Wen
    Shie, Kai-Cheng
    Chen, Chih
    MATERIALS CHARACTERIZATION, 2022, 194
  • [38] Non-destructive analysis of flake properties in automotive paints with full-field optical coherence tomography and 3D segmentation
    Zhang, Jinke
    Williams, Bryan M.
    Lawman, Samuel
    Atkinson, David
    Zhang, Zijian
    Shen, Yaochun
    Zheng, Yalin
    OPTICS EXPRESS, 2017, 25 (16): : 18614 - 18628
  • [39] Non-destructive testing of layer-to-layer fusion of a 3D print using ultrahigh resolution optical coherence tomography
    Israelsen, Niels M.
    Maria, Michael
    Feuchter, Thomas
    Podoleanu, Adrian
    Bang, Ole
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [40] A Non-Destructive Technique Using 3D X-ray Computed Tomography to Reveal Semiconductor Internal Physical Defects
    Tan, C. H.
    Lau, C. K.
    2013 IEEE INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING APPLICATIONS (IEEE ICSIPA 2013), 2013, : 55 - 60