Continuous Fc detection for protein A capture process control

被引:9
|
作者
Patil, Ujwal [1 ]
Crum, Mary [2 ]
Binh Vu [2 ]
Wasden, Katherine [2 ]
Kourentzi, Katerina [2 ]
Willson, Richard C. [1 ,2 ,3 ]
机构
[1] Univ Houston, Biol & Biochem, Houston, TX 77004 USA
[2] Univ Houston, Chem & Biomol Engn, Houston, TX USA
[3] Escuela Med & Ciencias Salud TecSalud, Monterrey, Nuevo Leon, Mexico
来源
关键词
Process analytical technology; Real-time monitoring; Protein A chromatography; Fluorescence polarization; Fluorescence intensity; Antibody breakthrough; PROCESS ANALYTICAL TECHNOLOGY; MID INFRARED-SPECTROSCOPY; HOST-CELL PROTEINS; IMMUNOGLOBULIN-G; CHROMATOGRAPHY; ADSORPTION; BINDING; PURIFICATION; DEFINITION; DESIGN;
D O I
10.1016/j.bios.2020.112327
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purification of therapeutic monoclonal antibodies usually involves a protein A affinity capture step. Because column breakthrough of antibody in complex, UV-absorbing culture fluid cannot be readily detected in real time, processes are designed so conservatively that column capacity is usually underutilized, wasting adsorbent and reducing productivity. We have developed a fluorescence-based monitoring technology which allows real-time mAb monitoring and used it to detect IgG in column breakthrough. The column effluent was continuously contacted with soluble fluorescein-labeled Fc-binding ligands to produce an immediately-detectable shift in both fluorescence polarization and intensity. To extend the upper limit of inlet flow rate, a 14:1 split-ratio flow splitter was tested with an inlet flow of 15 mL/min (0.9 L/h), producing a sampling stream at 1 mL/min while still enabling continuous detection functionality. We observed significant shifts in fluorescence intensity in CHO cell culture fluid spiked with human IgG, and detected 0.02-0.1 g/L human IgG in protein A column breakthrough at a flow velocity of 80 cm/h. The increase in fluorescence intensity upon 0.1% breakthrough of an 1 g/L feed was used to trigger column switching using Python-enabled two-way communication with the standard Unicorn OPC process control protocol. The technology allows rapid, continuous and reliable monitoring of IgG in a flowing process stream, without elaborate sample preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Continuous process control by impulse thermography
    Florin, C
    INSIGHT, 1998, 40 (03) : 201 - 202
  • [22] Continuous process control by impulse thermography
    Florin, C.
    Insight: Non-Destructive Testing and Condition Monitoring, 1998, 40 (03): : 201 - 202
  • [23] Control aspects of the Mitsubishi continuous process
    Goto, M
    Oshima, E
    Hayashi, M
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1998, 50 (04): : 60 - +
  • [24] CONTINUOUS INFRARED ANALYZERS FOR PROCESS CONTROL
    SAVITZKY, A
    WOODHULL, EH
    WEBER, AP
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1956, 48 (06): : 1047 - 1052
  • [25] Process integration and control in continuous bioprocessing
    Rathore, Anurag S.
    Kateja, Nikhil
    Kumar, Devashish
    CURRENT OPINION IN CHEMICAL ENGINEERING, 2018, 22 : 18 - 25
  • [26] Model-based process development and evaluation of twin-column continuous capture processes with Protein A affinity resin
    Sun, Yan-Na
    Shi, Ce
    Zhang, Qi-Lei
    Yao, Shan-Jing
    Slater, Nigel K. H.
    Lin, Dong-Qiang
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1625
  • [27] Capture-recapture experiments with time heterogeneous capture probabilities in continuous time: A counting process approach
    Huggins, R
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2004, 33 (05) : 1221 - 1238
  • [28] Capture process control needs to create functional specifications
    Harrold, D
    CONTROL ENGINEERING, 1999, 46 (06) : 88 - 88
  • [29] Command and control process capture and modeling with collaborative workflow
    Burchett, Tracy
    Dunaway, Brad
    Green, David
    Reaper, Jerome
    WMSCI 2005: 9th World Multi-Conference on Systemics, Cybernetics and Informatics, Vol 10, 2005, : 1 - 6
  • [30] Continuous Protein Modification and Separation Process with Chromatography
    Yoshimoto N.