Comparison of blood flow velocity through the internal carotid artery based on Doppler ultrasound and numerical simulation

被引:6
|
作者
Hassani-Ardekani, Hajar [1 ]
Ghalichi, Farzan [1 ]
Niroomand-Oscuii, Hanieh [1 ]
Farhoudi, Mehdi [2 ]
Tarzmani, Mohammad Kazem [3 ]
机构
[1] Sahand Univ Technol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Neurosci Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Dept Radiol, Tabriz, Iran
关键词
Blood velocimetry; Doppler ultrasound; Non-Newtonian fluid; Fluid-solid interaction; Turbulence model; FLUID-STRUCTURE INTERACTION; VESSEL MECHANICS; UNSTEADY; STENOSIS; MODEL;
D O I
10.1007/s13246-012-0162-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Doppler ultrasound is a usual non-invasive method to estimate the stenosis percentage in large arteries such as carotid by measuring maximum velocity of blood flow. Based on clinical investigations, because of vessel wall motions, Doppler positioning and angle correction, some errors can arise in Doppler results which lead to incorrect diagnosis. The aim of this study was to compare the results of Doppler test and the numerical simulation of blood flow in the same case. For this evaluation, two patients including an 87-year-old man and a 72-year-old woman suffering from stenosis in the internal carotid artery were selected. First, clinical information of each patient such as CT-Angio scan images and Doppler ultrasound results on different locations of the stenosed artery were obtained. Then, the geometries were reconstructed and numerical simulations were carried out using ANSYS software. Results showed that the velocity profile of Doppler test and numerical simulation were in good agreement at the regions of pre-and post-stenosis. However, the value of maximum velocity at the stenotic region had significant differences.
引用
收藏
页码:413 / 422
页数:10
相关论文
共 50 条
  • [21] Intracerebral laser Doppler blood flow measurements compared to blood flow in porcine internal carotid artery
    Kirkeby, OJ
    Rise, IR
    JOURNAL OF CLINICAL NEUROSCIENCE, 1999, 6 (05) : 389 - 394
  • [22] Carotid Flow Volume Measurement in Doppler Ultrasound as a New Look at the Diagnosis of Internal Carotid Artery Stenosis
    Kaszczewski, Piotr
    Elwertowski, Micha
    Leszczynski, Jerzy
    Ostrowski, Tomasz
    Galazka, Zbigniew
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (05) : E162 - E162
  • [23] Intermittent drop in blood flow velocity in the internal carotid artery and its branches
    Samii, C
    Diehl, RR
    Berlit, P
    JOURNAL OF CLINICAL ULTRASOUND, 2002, 30 (02) : 98 - 102
  • [24] FAILURE OF AUTOREGULATION OF CEREBRAL BLOOD-FLOW IN NEONATES STUDIED BY PULSED DOPPLER ULTRASOUND OF THE INTERNAL CAROTID-ARTERY
    JORCH, G
    JORCH, N
    EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (05) : 468 - 472
  • [25] CALCULATION OF CAROTID ARTERY FLOW RATES USING DOPPLER ULTRASOUND: IMPLICATIONS OF VELOCITY PROFILE SKEWING
    Mynard, Jonathan P.
    Steinman, David A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 85 - 86
  • [26] DOPPLER ULTRASOUND ASSESSMENT OF THE INTERNAL CAROTID-ARTERY FOLLOWING CAROTID ENDARTERECTOMY
    PADAYACHEE, TS
    LEWIS, RR
    YATES, AK
    GOSLING, RG
    STROKE, 1983, 14 (06) : 990 - 994
  • [27] THE MEASUREMENT OF THE INTERNAL CAROTID ARTERIAL BLOOD VELOCITY IN CEREBRAL-PALSIED CHILDREN BY THE DOPPLER ULTRASOUND METHOD
    FUTAGI, Y
    SHIMIZU, H
    ABE, J
    ONOE, S
    YABUUCHI, H
    KAJIURA, I
    SUMI, K
    BRAIN & DEVELOPMENT, 1981, 3 (02): : 188 - 188
  • [28] Quantification of Internal Carotid Artery Flow with Digital Subtraction Angiography: Validation of an Optical Flow Approach with Doppler Ultrasound
    Pereira, V. Mendes
    Ouared, R.
    Brina, O.
    Bonnefous, O.
    Satwiaski, J.
    Aerts, H.
    Ruijters, D.
    van Nijnatten, F.
    Perren, F.
    Bijlenga, P.
    Schaller, K.
    Lovblad, K-O
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) : 156 - 163
  • [29] Intravascular ultrasound Doppler measurement of blood flow velocity
    Schumacher, M
    Yin, L
    Swaid, S
    Oldenburger, J
    Gilsbach, JM
    Hetzel, A
    JOURNAL OF NEUROIMAGING, 2001, 11 (03) : 248 - 252
  • [30] TRANSCRANIAL DOPPLER MONITORING OF BLOOD-FLOW VELOCITY WITHIN THE MEDIAL CEREBRAL-ARTERY DURING RECANALIZING OPERATIONS ON THE INTERNAL CAROTID-ARTERY
    RINGELSTEIN, EB
    RICHERT, F
    BARDOS, S
    MINALE, C
    ALSUKUN, M
    ZEPLIN, H
    SCHONDUBE, F
    ZEUMER, H
    MESSMER, B
    NERVENARZT, 1985, 56 (08): : 423 - 430