Comparison of different methods for measuring thermal conductivities

被引:1
|
作者
Hartung, D. [1 ]
Gather, F. [1 ]
Klar, P. J. [1 ]
机构
[1] Univ Giessen, Inst Phys 1, D-35392 Giessen, Germany
关键词
Thermal conductivity measurements; 3; omega-method; glass; DIFFUSIVITY;
D O I
10.1063/1.4731576
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two different methods for the measurement of the thermal conductivity have been applied to a glass (borosilicate) bulk sample. The first method was in the steady-state using an arrangement of gold wires on the sample to create a thermal gradient and to measure the temperatures locally. This allows one to calculate the in-plane thermal conductivity of the sample. The same wire arrangement was also used for a 3 omega-measurement of the direction-independent bulk thermal conductivity. The 3 omega-approach is based on periodical heating and a frequency dependent analysis of the temperature response. The results of both methods are in good agreement with each other for this isotropic material, if thermal and radiative losses are accounted for. Our results demonstrate that especially in the case of thin-film measurements, finite element analysis has to be applied to correct for heat losses due to geometry and radiation. In this fashion, the wire positions can be optimized in order to minimize measurement errors
引用
收藏
页码:381 / 384
页数:4
相关论文
共 50 条
  • [21] Comparison of thermal conductivities of polypropylene fibers and fibrils
    Hao Yin
    Chenhan Liu
    Bin Wang
    Yong Li
    Xue Hu
    Junyao Yin
    Jinbo Liu
    Gutian Zhao
    Juekuan Yang
    Heat and Mass Transfer, 2024, 60 : 677 - 684
  • [22] Comparison of thermal conductivities of polypropylene fibers and fibrils
    Yin, Hao
    Liu, Chenhan
    Wang, Bin
    Li, Yong
    Hu, Xue
    Yin, Junyao
    Liu, Jinbo
    Zhao, Gutian
    Yang, Juekuan
    HEAT AND MASS TRANSFER, 2024, 60 (04) : 677 - 684
  • [23] A COMPARISON OF 2 METHODS FOR MEASURING THERMAL THRESHOLDS IN DIABETIC NEUROPATHY
    LEVY, D
    ABRAHAM, R
    REID, G
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1989, 52 (09): : 1072 - 1077
  • [24] Comparison of different methods of measuring similarity in physiologic time series
    Kianimajd, A.
    Ruano, M. G.
    Carvalho, P.
    Henriques, J.
    Rocha, T.
    Paredes, S.
    Ruano, A. E.
    IFAC PAPERSONLINE, 2017, 50 (01): : 11005 - 11010
  • [25] Comparison of Different Methods for Measuring Immunoglobulin Content in Calf Serum
    Mette Bagger
    Lis Eriksen
    Acta Veterinaria Scandinavica, 44 (Suppl 1)
  • [26] Comparison of different methods for measuring the passive film thickness on metals
    Benoit, Marie
    Bataillon, Christian
    Gwinner, Benoit
    Miserque, Frederic
    Orazem, Mark E.
    Sanchez-Sanchez, Carlos M.
    Tribollet, Bernard
    Vivier, Vincent
    ELECTROCHIMICA ACTA, 2016, 201 : 340 - 347
  • [27] Comparison of different dilution methods for measuring diesel particle emissions
    Lyyränen, J
    Jokiniemi, J
    Kauppinen, EI
    Backman, U
    Vesala, H
    AEROSOL SCIENCE AND TECHNOLOGY, 2004, 38 (01) : 12 - 23
  • [28] Comparison of different methods for measuring intra-abdominal pressure
    Gudmundsson, FF
    Viste, A
    Gislason, H
    Svanes, K
    INTENSIVE CARE MEDICINE, 2002, 28 (04) : 509 - 514
  • [29] Measuring Prosodic Entrainment in Conversation: A Review and Comparison of Different Methods
    Kruyt, Joanna
    de Jong, Dorina
    D'Ausilio, Alessandro
    Benus, Stefan
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2023, 66 (11): : 4280 - 4314
  • [30] A comparison of three different methods for measuring intact casein in cheese
    Lehtola, P.
    Metzger, L. E.
    POULTRY SCIENCE, 2004, 83 : 285 - 285