Ab initio calculations and iodine kinetic modeling in the reactor coolant system of a pressurized water reactor in case of severe nuclear accident

被引:26
|
作者
Xerri, Bertrand [2 ,3 ]
Canneaux, Sebastien [1 ,3 ]
Louis, Florent [1 ,3 ]
Trincal, Julien [2 ]
Cousin, Frederic [2 ,3 ]
Badawi, Michael [2 ,3 ]
Cantrel, Laurent [2 ,3 ]
机构
[1] Univ Lille 1 Sci & Technol, UMR CNRS Lille 1 8522, F-59655 Villeneuve Dascq, France
[2] Ctr Cadarache, DPAM SEMIC, Inst Radioprotect & Sarete Nucl, F-13115 St Paul Les Durance, France
[3] Ctr Cadarache, Lab Rech Commun IRSN CNRS Lille Cinet Chim Combus, F-13115 St Paul Les Durance, France
关键词
Iodine kinetic modeling; Ab initio calculations; Potential energy profile; ASTEC software; Nuclear safety; GAS-PHASE REACTIONS; GAUSSIAN-BASIS SETS; CORRELATED MOLECULAR CALCULATIONS; QUADRATIC CONFIGURATION-INTERACTION; FISSION-PRODUCT TRANSPORT; COUPLED-CLUSTER SINGLES; THERMOCHEMICAL PROPERTIES; ABSTRACTION REACTIONS; STATE THEORY; PHEBUS FP;
D O I
10.1016/j.comptc.2012.02.024
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A kinetic model for iodine, oxygen and hydrogen is proposed in order to simulate transport of iodine along the reactor coolant system (RCS) of a Pressurized Water Reactor (PWR) in case of a severe accident. This kinetic mechanism is composed of 33 reactions. Due to lack of data in the literature for many gaseous iodine reactions, ab initio methods have been employed to determine rate constants as it was already the case in our previous works (Canneaux et al. J. Phys. Chem. A 114 (2010) 9270; Hammaecher et al. J. Phys. Chem. A 115 (2011) 6664). These computational studies have been completed here with calculations for the I/H substitution in HOI and iodine abstraction from hypoiodous acid by H and I (P-2(3/2)) atoms. The rate constants have been estimated using the same methodology over the temperature range (300-2500 K). After being implemented in the ASTEC software (Accident Source Term Evaluation Code), simple computations were performed to assess time needed to reach equilibrium at three different temperatures: 1000, 1200, and 1400 K in a batch reactor at a constant pressure of 2 x 10(5) Pa. The influence of gas composition has been also examined using four different gas compositions: pure steam, pure hydrogen, and two hydrogen/steam intermediate mixtures containing in weighted percentages either 20/80 or 80/20%(w). The PHEBUS-FPT1 experimental test was re-interpreted in activating with the kinetics of the I-O-H reaction system instead of thermodynamic equilibrium assumption. As expected, the kinetics promoted the persistence of gaseous iodine fraction at low temperature (428 K) as observed in the PHEBUS tests and thermodynamic equilibrium assumption appeared to be too simplistic to get accurate iodine speciation at the break and thus reliable source term(1) estimations. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:194 / 208
页数:15
相关论文
共 50 条
  • [31] UNSTABLE CRACK PROPAGATION UNDER SEVERE ACCIDENT SCENARIO CONDITIONS IN A PRESSURIZED WATER REACTOR
    Tardif, Nicolas
    Coret, Michel
    Combescure, Alain
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2009, VOL 5, 2010, : 343 - 350
  • [32] Numerical Study of Natural Circulation Flow in Reactor Coolant System during a Severe Accident
    Choi, Dae Kyung
    Park, Won Man
    Son, Sung Man
    Lim, Kukhee
    Cho, Yong Jin
    Choi, Choengryul
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2022, 2022
  • [33] CHEMICAL-EQUILIBRIA FOR ACCIDENT ANALYSIS IN PRESSURIZED WATER NUCLEAR-REACTOR SYSTEMS
    POTTER, PE
    RAND, MH
    CALPHAD-COMPUTER COUPLING OF PHASE DIAGRAMS AND THERMOCHEMISTRY, 1983, 7 (02): : 165 - 174
  • [34] Weld Heat Input and Stress Corrosion Cracking of Alloy 182 Filler in a Pressurized Water Reactor Nuclear Reactor Coolant Environment
    Silva, G. M.
    Bracarense, A. Q.
    Schvartzman, M. M. A. M.
    CORROSION, 2011, 67 (07)
  • [35] EVALUATION TO DETERMINE FEASIBILITY OF REUSE OF REACTOR COOLANT IN A PRESSURIZED WATER NUCLEAR-POWER PLANT
    WEBSTER, BH
    PADGETT, JA
    HEALTH PHYSICS, 1974, 27 (06): : 652 - 653
  • [36] HAZARDS EVALUATION OF PRIMARY-TO-SECONDARY SYSTEM COOLANT LEAKAGE IN A PRESSURIZED WATER REACTOR
    SMITH, ER
    DANIELS, RS
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1968, 11 (01): : 371 - &
  • [37] CALCULATIONS OF THERMAL PARAMETERS IN THE CONTAINMENT OF A PWR NUCLEAR-REACTOR DURING LOSS-OF-COOLANT ACCIDENT
    FIC, A
    SKOREK, J
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1993, 73 (7-8): : T729 - T731
  • [38] Research on Evaluation Method of Actinide Nuclide Activities in Primary Coolant System of Pressurized Water Reactor Nuclear Power Plant
    Xiong J.
    Lyu W.
    Guo R.
    Gao Y.
    Jiang Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (02): : 47 - 52
  • [39] Investigations of the Reflood-phase after a Loss-of-coolant-accident of an Advanced Pressurized Water Reactor (APWR).
    Schumann, Soenke
    Atomkernenergie, Kerntechnik, 1983, 42 (02): : 80 - 91
  • [40] INTERFACING SYSTEMS LOSS-OF-COOLANT ACCIDENT IN OCONEE UNIT-1 PRESSURIZED WATER-REACTOR
    NASSERSHARIF, B
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 47 : 258 - 260