Application of near infrared spectroscopy in monitoring the moisture content in freeze-drying process of human coagulation factor VIII

被引:10
|
作者
Wang, Fei [1 ,2 ]
Jiang, Wei [1 ,2 ]
Li, Can [1 ,2 ]
Zhang, Hui [3 ]
Nie, Lei [1 ,2 ]
Li, Lian [1 ,2 ]
Wang, Pei [4 ]
Zang, Hengchang [1 ,2 ]
机构
[1] Shandong Univ, Sch Pharmaceut Sci, Jinan 250012, Peoples R China
[2] Shandong Univ, Natl Glycoengn Res Ctr, Jinan 250012, Peoples R China
[3] Beijing Kaiyuan Shengshi Sci & Technol Dev Co Ltd, Jinan 250012, Peoples R China
[4] Shenyang Pharmaceut Univ, Sch Pharm, Shenyang 110016, Peoples R China
关键词
Near infrared spectroscopy; freeze-drying; moisture content determination; IN-LINE; END-POINT; VALIDATION; CALIBRATION;
D O I
10.1142/S1793545815500340
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As an important process analysis tool, near infrared spectroscopy (NIRS) has been widely used in process monitoring. In the present work, the feasibility of NIRS for monitoring the moisture content of human coagulation factor VIII (FVIII) in freeze-drying process was investigated. A partial least squares regression (PLS-R) model for moisture content determination was built with 88 samples. Different pre-processing methods were explored, and the best method found was standard normal variate (SNV) transformation combined with 1st derivation with Savitzky-Golay (SG) 15 point smoothing. Then, four different variable selection methods, including uninformative variable elimination (UVE), interval partial least squares regression (iPLS), competitive adaptive reweighted sampling (CARS) and manual method, were compared for eliminating irrelevant variables, and iPLS was chosen as the best variable selection method. The correlation coefficient (R), correlation coefficient of calibration set (R-cal), correlation coefficient of validation set (R-val), root mean square errors of cross-validation (RMSECV) and root mean square errors of prediction (RMSEP) of PLS model were 0.9284, 0.9463, 0.8890, 0.4986% and 0.4514%, respectively. The results showed that the model for moisture content determination has a wide range, good linearity, accuracy and precision. The developed approach was demonstrated to be a potential for monitoring the moisture content of FVIII in freeze-drying process.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Moisture content monitoring in withering leaves during black tea processing based on electronic eye and near infrared spectroscopy
    Jiayou Chen
    Chongshan Yang
    Changbo Yuan
    Yang Li
    Ting An
    Chunwang Dong
    Scientific Reports, 12
  • [42] Monitoring moisture content in parchment coffee beans during drying using Fourier Transform near infrared (FT-NIR) spectroscopy: A dataset for calibrating chemometric-based models for moisture prediction
    Ordonez-Lozano, Sandrith
    Collazos-Escobar, Gentil A.
    Bahamon-Monje, Andres F.
    Gutierrez-Guzman, Nelson
    DATA IN BRIEF, 2025, 59
  • [43] A novel combined application of capacitive method and near-infrared spectroscopy for predicting the density and moisture content of solid wood
    Vu Thi Hong Tham
    Tetsuya Inagaki
    Satoru Tsuchikawa
    Wood Science and Technology, 2018, 52 : 115 - 129
  • [44] A novel combined application of capacitive method and near-infrared spectroscopy for predicting the density and moisture content of solid wood
    Vu Thi Hong Tham
    Inagaki, Tetsuya
    Tsuchikawa, Satoru
    WOOD SCIENCE AND TECHNOLOGY, 2018, 52 (01) : 115 - 129
  • [45] Application of Near Infrared Reflectance (NIR) spectroscopy to predict the moisture, protein, and fat content of beef for gourmet hamburger preparation
    Maduro Dias, C. S. A. M.
    Nunes, H. P.
    Melo, T. M. M., V
    Rosa, H. J. D.
    Silva, C. C. G.
    Borba, A. E. S.
    LIVESTOCK SCIENCE, 2021, 254
  • [46] Application of Near-Infrared Reflectance Spectroscopy for Determination of Gambir (Uncaria gambir Roxb.) Moisture and Catechin Content
    Andasuryani
    Purwanto, Y. A.
    Budiastra, I. W.
    Syamsu, K.
    II ASIA PACIFIC SYMPOSIUM ON POSTHARVEST RESEARCH EDUCATION AND EXTENSION (APS2012), 2013, 1011 : 299 - 306
  • [47] Transfer of a near infrared spectroscopy laboratory application to an online process analyser for in situ monitoring of anaerobic digestion
    Krapf, L. Christian
    Nast, Dieter
    Gronauer, Andreas
    Schmidhalter, Urs
    Heuwinkel, Hauke
    BIORESOURCE TECHNOLOGY, 2013, 129 : 39 - 50
  • [48] Application of near-infrared spectroscopy combined with multivariate analysis in monitoring of crude heparin purification process
    Zang, Hengchang
    Wang, Jinfeng
    Li, Lian
    Zhang, Hui
    Jiang, Wei
    Wang, Fengshan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 109 : 8 - 13
  • [49] The application of near infrared spectroscopy in process monitoring of solid-state fermentation of sweet sorghum stalks
    Fan, Guifang
    Jiang, Yan
    Li, Guangming
    Xu, Weiliang
    Chang, Sandra
    Zhang, Lei
    Li, Jihong
    Zhao, Gang
    Li, Shizhong
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2015, 23 (05) : 293 - 299
  • [50] In-line near infrared spectroscopy during freeze-drying as a tool to measure efficiency of hydrogen bond formation between protein and sugar, predictive of protein storage stability
    Mensink, Maarten A.
    Van Bockstal, Pieter-Jan
    Pieters, Sigrid
    De Meyer, Laurens
    Frijlink, Henderik W.
    Maarschalk, Kees van der Voort
    Hinrichs, Wouter L. J.
    De Beer, Thomas
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 496 (02) : 792 - 800