Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers

被引:18
|
作者
Geiger, MJ
ONeill, P
Sharma, A
Skadsen, A
Zimerman, L
Greenfield, RA
Newby, KH
Wharton, JM
Kent, V
Natale, A
机构
[1] VET ADM MED CTR,DURHAM,NC 27705
[2] DUKE UNIV,MED CTR,DEPT CARDIOL,DURHAM,NC
[3] UNIV CALIF DAVIS,SACRAMENTO,CA 95817
来源
关键词
transvenous defibrillator; pacemaker; malfunction;
D O I
10.1111/j.1540-8159.1997.tb03880.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Limited information is available regarding potential adverse interactions between transvenous nonthoracotomy cardioverter defibrillators and pacemakers. We describe our experience with 37 patients who have undergone successful implantation of both a transvenous defibrillator and pacemaker. The patients' mean age was 64 +/- 12.9 years. Thirty-three were male and four were female. The mean LVEF was 30.8 +/- 11.8%. The indications for pacemaker implantation included sick sinus syndrome in 13 patients, complete heart block in 15 patients, sinus bradycardia secondary to medications in 8 patients, and neurocardiogenic syncope in 1 patient. The indications for insertion of a defibrillator included medically refractory VT in 27 patients and sudden cardiac death in 10 patients. Twenty-three patients received an Endotak lead and 14 patients received a Transvene lead. Eighteen patients had a pacemaker prior to an ICD, 14 patients had an ICD prior to a pacemaker, and 4 patients had both devices placed simultaneously. Interaction was evaluated at implant of the second device and 1-3 days after both devices were placed. Detection of VF/VT was analyzed during asynchronous pacing (DOO/VOO) with maximum pacing output. In addition, in six patients, DFT was determined before and after pacemaker implantation. In 14 patients (38%), device interactions that could not always be optimally corrected were observed. In five patients, the pacemaker was reset to the ''noise reversion'' mode after high energy ICD discharge. Oversensing of atrial pacemaker stimuli resulted in inappropriate ICD firings in four patients. This was observed only with a specific device and could not be prevented by atrial lead repositioning in two of them, but required reprogramming of the pacemaker to the VVI mode. An increase in DFT was observed in five patients who had a pacemaker implanted after an ICD. Compared with previously published studies, a greater frequency of transvenous ICD and pacemaker interactions were observed. Considering that almost 50% of the patients already have a pacemaker at the time of ICD implant, the availability of defibrillators with dual chamber pacing capability will not eliminate the potential for this problem.
引用
收藏
页码:624 / 630
页数:7
相关论文
共 50 条
  • [31] Cardioverter - Defibrillator twiddler's syndrome in a subpectoral transvenous system
    Lolli, G
    Menozzi, C
    Bottoni, N
    Dondina, C
    HEARTWEB, 1997, 3 (01): : U2 - +
  • [32] Sensitivity and Spatial Resolution of Transvenous Leads in Implantable Cardioverter Defibrillator
    Requena-Carrion, Jesus
    Vaisanen, Juho
    Alonso-Atienza, Felipe
    Garcia-Alberola, Arcadi
    Javier Ramos-Lopez, Francisco
    Luis Rojo-Alvarez, Jose
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (12) : 2773 - 2781
  • [33] Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
    Borleffs, C. Jan Willem
    van Erven, Lieselot
    van Bommel, Rutger J.
    van der Velde, Enno T.
    van der Wall, Ernst E.
    Bax, Jeroen J.
    Rosendaal, Frits R.
    Schalij, Martin J.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04): : 411 - 416
  • [34] INFECTIVE ENDOCARDITIS OF THE TRANSVENOUS LEAD OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    WERNER, GS
    GONSKA, BD
    HERSE, B
    KREUZER, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (01): : 51 - 54
  • [35] Combined dynamic cardiomyoplasty and transvenous implantable cardioverter defibrillator system
    Sideris, AM
    Sioras, E
    Filippatos, GS
    Kardara, D
    Kardaras, F
    Anthopoulos, L
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 69 (01) : 93 - 96
  • [36] CHRONIC DEFIBRILLATION THRESHOLDS IN AN IMPLANTED TRANSVENOUS CARDIOVERTER DEFIBRILLATOR SYSTEM
    VENDITTI, FJ
    VASSOLAS, G
    MARTIN, D
    CIRCULATION, 1992, 86 (04) : 441 - 441
  • [37] ANESTHESIA FOR TRANSVENOUS INSERTION OF AN AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    CASHMAN, JN
    GARCIARODRIGUEZ, C
    LAMOND, C
    ANAESTHESIA, 1992, 47 (08) : 720 - 721
  • [38] Transvenous pectoral implantation of single lead implantable cardioverter defibrillator
    王方正
    华伟
    陈新
    Chinese Medical Journal, 1999, (01)
  • [39] Transvenous pectoral implantation of single lead implantable cardioverter defibrillator
    王方正
    华伟
    陈新
    中华医学杂志(英文版), 1999, (01) : 23 - 25
  • [40] INITIAL EXPERIENCE WITH TRANSVENOUS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD SYSTEMS - OPERATIVE MORBIDITY AND MORTALITY
    FRAME, R
    BRODMAN, R
    GROSS, J
    HOLLINGER, I
    FISHER, JD
    KIM, SG
    FERRICK, K
    ROTH, J
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 149 - 152