Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers

被引:18
|
作者
Geiger, MJ
ONeill, P
Sharma, A
Skadsen, A
Zimerman, L
Greenfield, RA
Newby, KH
Wharton, JM
Kent, V
Natale, A
机构
[1] VET ADM MED CTR,DURHAM,NC 27705
[2] DUKE UNIV,MED CTR,DEPT CARDIOL,DURHAM,NC
[3] UNIV CALIF DAVIS,SACRAMENTO,CA 95817
来源
关键词
transvenous defibrillator; pacemaker; malfunction;
D O I
10.1111/j.1540-8159.1997.tb03880.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Limited information is available regarding potential adverse interactions between transvenous nonthoracotomy cardioverter defibrillators and pacemakers. We describe our experience with 37 patients who have undergone successful implantation of both a transvenous defibrillator and pacemaker. The patients' mean age was 64 +/- 12.9 years. Thirty-three were male and four were female. The mean LVEF was 30.8 +/- 11.8%. The indications for pacemaker implantation included sick sinus syndrome in 13 patients, complete heart block in 15 patients, sinus bradycardia secondary to medications in 8 patients, and neurocardiogenic syncope in 1 patient. The indications for insertion of a defibrillator included medically refractory VT in 27 patients and sudden cardiac death in 10 patients. Twenty-three patients received an Endotak lead and 14 patients received a Transvene lead. Eighteen patients had a pacemaker prior to an ICD, 14 patients had an ICD prior to a pacemaker, and 4 patients had both devices placed simultaneously. Interaction was evaluated at implant of the second device and 1-3 days after both devices were placed. Detection of VF/VT was analyzed during asynchronous pacing (DOO/VOO) with maximum pacing output. In addition, in six patients, DFT was determined before and after pacemaker implantation. In 14 patients (38%), device interactions that could not always be optimally corrected were observed. In five patients, the pacemaker was reset to the ''noise reversion'' mode after high energy ICD discharge. Oversensing of atrial pacemaker stimuli resulted in inappropriate ICD firings in four patients. This was observed only with a specific device and could not be prevented by atrial lead repositioning in two of them, but required reprogramming of the pacemaker to the VVI mode. An increase in DFT was observed in five patients who had a pacemaker implanted after an ICD. Compared with previously published studies, a greater frequency of transvenous ICD and pacemaker interactions were observed. Considering that almost 50% of the patients already have a pacemaker at the time of ICD implant, the availability of defibrillators with dual chamber pacing capability will not eliminate the potential for this problem.
引用
收藏
页码:624 / 630
页数:7
相关论文
共 50 条
  • [1] IMPLANTATION OF TRANSVENOUS NONTHORACOTOMY CARDIOVERTER-DEFIBRILLATOR SYSTEMS IN PATIENTS WITH PERMANENT ENDOCARDIAL PACEMAKERS
    BROOKS, R
    GARAN, H
    MCGOVERN, BA
    RUSKIN, JN
    AMERICAN HEART JOURNAL, 1995, 129 (01) : 45 - 53
  • [2] TRANSVENOUS ENDOCARDIAL CARDIOVERTER-DEFIBRILLATOR SYSTEMS - IS THE FUTURE HERE
    MANOLIS, AS
    ARCHIVES OF INTERNAL MEDICINE, 1994, 154 (06) : 617 - 622
  • [3] A PERMANENT TRANSVENOUS LEAD SYSTEM FOR AN IMPLANTABLE PACEMAKER CARDIOVERTER-DEFIBRILLATOR - NONTHORACOTOMY APPROACH TO IMPLANTATION
    YEE, R
    KLEIN, GJ
    LEITCH, JW
    GUIRAUDON, GM
    GUIRAUDON, CM
    JONES, DL
    NORRIS, C
    CIRCULATION, 1992, 85 (01) : 196 - 204
  • [4] The combined transvenous implantation of cardioverter defibrillators and permanent pacemakers
    Mattke, S
    Markewitz, A
    Muller, D
    Grunewald, A
    Fiek, M
    Schmockel, M
    Hoffmann, E
    Steinbeck, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (11): : 2775 - 2782
  • [5] Combined therapy with transvenous implantable cardioverter/defibrillator and permanent pacemaker systems
    Sticherling, C
    Klingenheben, T
    Skupin, M
    Li, YG
    Hohnloser, SH
    ZEITSCHRIFT FUR KARDIOLOGIE, 1997, 86 (02): : 105 - 112
  • [6] COMPLICATIONS WITH PERMANENT TRANSVENOUS PACEMAKERS
    BEREGOVICH, J
    FENIG, S
    NEW YORK STATE JOURNAL OF MEDICINE, 1970, 70 (06) : 761 - +
  • [7] CONSIDERATIONS OF COMPLICATIONS OF PERMANENT TRANSVENOUS PACEMAKERS
    YOUMANS, CR
    DERRICK, JR
    WALLACE, JM
    AMERICAN JOURNAL OF SURGERY, 1967, 114 (05): : 704 - &
  • [8] MANAGEMENT OF INFECTED TRANSVENOUS PERMANENT PACEMAKERS
    KENNELLY, BM
    PILLER, LW
    BRITISH HEART JOURNAL, 1974, 36 (11): : 1133 - 1140
  • [9] RESULTS AND EXPERIENCE WITH TRANSVENOUS CARDIOVERTER DEFIBRILLATOR THERAPY
    TRAPPE, HJ
    FIEGUTH, HG
    WEBERCONRAD, O
    SCHOHL, W
    WAHLERS, T
    KIELBLOCK, B
    WENZLAFF, P
    KLEIN, H
    LICHTLEN, PR
    MEDIZINISCHE KLINIK, 1992, 87 (12) : 615 - 621
  • [10] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTED BY NONTHORACOTOMY APPROACH - INITIAL CLINICAL-EXPERIENCE WITH THE REDESIGNED TRANSVENOUS LEAD SYSTEM
    MOORE, SL
    MALONEY, JD
    EDEL, TB
    MCGUINN, WP
    GOHN, D
    MORANT, VA
    TROHMAN, R
    SIMMONS, TW
    WILKOFF, BL
    CASTLE, LW
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11): : 1865 - 1869