Real-time optimal combination of multifrequency information in phase-resolved luminescence spectroscopy based on rectangular-wave signals

被引:4
|
作者
Medina-Rodriguez, Santiago [1 ,2 ]
Medina-Rodriguez, Carlos [1 ]
de la Torre-Vega, Angel [1 ]
Segura-Luna, Jose C. [1 ]
Mota-Fernandez, Sonia [1 ]
Fernandez-Sanchez, Jorge F. [2 ]
机构
[1] Univ Granada, CITIC UGR, Dept Signal Theory Telemat & Commun, C Periodista Rafael Gomez 2, E-18071 Granada, Spain
[2] Univ Granada, Fac Sci, Dept Analyt Chem, Av Fuente Nueva S-N, E-18071 Granada, Spain
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 238卷
关键词
Chemical sensor; Luminescence spectroscopy; Oxygen sensing; Standard error; Phase-resolved; Multifrequency; MODULATION METHOD; MEASURING SYSTEM; LIFETIME; FLUORESCENCE;
D O I
10.1016/j.snb.2016.07.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for optimally combining multifrequency information in phase-resolved luminescence spectroscopy using rectangular-wave signals is proposed to improve the accuracy in the determination of the analyte concentration. From the rectangular-wave signal, phase-shift- and modulation-factor-based apparent lifetimes are estimated at each harmonic independently, together with their corresponding standard errors. Both the lifetimes and their standard errors are estimated on-the-fly from the Fast Fourier Transform (FFT) of the excitation and emission signals and applying error propagation theory. Independent determinations of the analyte concentration and their standard errors are then optimally combined in order to obtain an improved determination of the analyte concentration. The combination, formulated in a statistical framework, is a weighted average of different determinations proportional to the inverse of the variance of each independent determination. The proposed method has been applied to an oxygen measuring system to evaluate its accuracy and demonstrate its applicability in real-time measuring instruments. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 50 条
  • [41] A haemodynamic brain-computer interface based on real-time classification of near infrared spectroscopy signals during motor imagery and mental arithmetic
    Stangl, Matthias
    Bauernfeind, Guenther
    Kurzmann, Juergen
    Scherer, Reinhold
    Neuper, Christa
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2013, 21 (03) : 157 - 171
  • [42] Novel real-time homodyne coherent receiver using a feed-forward based carrier extraction scheme for phase modulated signals
    Ibrahim, Selwan K.
    Sygletos, Stylianos
    Weerasuriya, Ruwan
    Ellis, Andrew D.
    OPTICS EXPRESS, 2011, 19 (09): : 8320 - 8326
  • [43] Real-Time Estimation for Roll Angle of Spinning Projectile Based on Phase-Locked Loop on Signals from Single-Axis Magnetometer
    Deng, Zhaowei
    Shen, Qiang
    Deng, Zilong
    Cheng, Jisi
    SENSORS, 2019, 19 (04)
  • [44] Freeway Driving Cycle Construction Based on Real-Time Traffic Information and Global Optimal Energy Management for Plug-In Hybrid Electric Vehicles
    He, Hongwen
    Guo, Jinquan
    Zhou, Nana
    Sun, Chao
    Peng, Jiankun
    ENERGIES, 2017, 10 (11):
  • [45] Real-time prediction of attitude and moving trajectory in shield tunneling based optimal input parameter combination using random forest deep learning method
    Shen, Xiang
    Chen, Xiangsheng
    Bao, Xiaohua
    Zhou, Ruiping
    Zhang, Guiyan
    ACTA GEOTECHNICA, 2023, 18 (12) : 6687 - 6707
  • [46] Real-time prediction of attitude and moving trajectory in shield tunneling based optimal input parameter combination using random forest deep learning method
    Xiang Shen
    Xiangsheng Chen
    Xiaohua Bao
    Ruiping Zhou
    Guiyan Zhang
    Acta Geotechnica, 2023, 18 : 6687 - 6707
  • [47] Real-time pixel based early apple bruise detection using short wave infrared hyperspectral imaging in combination with calibration and glare correction techniques
    Keresztes, Janos C.
    Goodarzi, Mohammad
    Saeys, Wouter
    FOOD CONTROL, 2016, 66 : 215 - 226
  • [48] Guided wave-based system for real-time cure monitoring of composites using piezoelectric discs and phase-shifted fiber Bragg gratings
    Hudson, Tyler B.
    Auwaijan, Nicolas
    Yuan, Fuh-Gwo
    JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (07) : 969 - 979
  • [49] Real-time tracking of radial artery vessel wall using a Kalman filter-based ultrasound single-plane wave RF signal time-frequency information fusion algorithm
    Liu, Liyuan
    Geng, Xingguang
    Yao, Fei
    Guo, Ziyang
    Zhang, Chaohong
    Zhang, Yitao
    Zhang, Haiying
    Wang, Yunfeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [50] Single-shot, real-time carrier-envelope phase measurement and tagging based on stereographic above-threshold ionization at short-wave infrared wavelengths
    Zhang, Yinyu
    Kellner, Philipp
    Adolph, Daniel
    Zille, Danilo
    Wustelt, Philipp
    Wuerzler, Daniel
    Skruszewicz, Slawomir
    Moeller, Max
    Sayler, A. Max
    Paulus, Gerhard G.
    OPTICS LETTERS, 2017, 42 (24) : 5150 - 5153