Elucidating the Body Surface P-wave using a Detailed Computer Model of Atrial Activation

被引:0
|
作者
Colman, Michael A. [1 ]
Giacopelli, Daniele
Langley, Phillip
Zhang, Henggui [1 ]
机构
[1] Univ Manchester, Manchester M13 9PL, Lancs, England
来源
2012 COMPUTING IN CARDIOLOGY (CINC), VOL 39 | 2012年 / 39卷
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Features of the ECG P-wave remain largely unexplained. P-wave notching is thought to relate to distinct events of right and left atrial activations. Wandering pacemaker is known to give rise to distinct P wave morphologies. In this study, we develop a 3D computational model of the human atria that is incorporated into a 3D human torso model which can simulate realistic P-waves across the torso. The atrial model considered detailed anatomical structure and electrophysiological heterogeneity. The torso model is used to produce ECG P-waves corresponding to those of the standard 12 lead ECG as well as a more detailed 64 lead electrode vest. The model is validated both in terms of the atrial activation sequence and the P-waves produced. The 12 lead ECG is then used to detect the presence of acetylcholine and isoprenaline on the atria. The 64 lead vest simulation is used to confirm that the presence of distinct P-wave modes in a clinical ECG is likely due to the presence of a leading pacemaker site shift, which may be caused by acetylcholine.
引用
收藏
页码:129 / 132
页数:4
相关论文
共 50 条
  • [21] Atrial myxoma surgery and P-wave remodeling
    Herrera, Cristian
    Bruna, Vanesa
    Barrio, Jose Maria
    Cuerpo, Gregorio
    Fernandez-Aviles, Francisco
    Bayes de Luna, Antonio
    Martinez-Selles, Manuel
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (09): : 1160 - 1164
  • [22] Influence at age on atrial activation as measured by the P-wave signal-averaged electrocardiogram
    Babaev, AA
    Vloka, ME
    Sadurski, R
    Steinberg, JS
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (06): : 692 - +
  • [23] Effect of Valsalva maneuver on surface electrocardiographic P-wave dispersion in paroxysmal atrial fibrillation
    Tükek, T
    Akkaya, V
    Demirel, S
    Sözen, AB
    Kudat, H
    Atilgan, D
    Özcan, M
    Güven, Ö
    Korkut, F
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (07): : 896 - +
  • [24] The effect of body position on P-wave axis
    Ng, J
    Sahakian, AV
    Swiryn, S
    COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 313 - 316
  • [25] Detection of patients at risk for paroxysmal atrial fibrillation improved by body surface mapping of P-wave signal-averaged ECG
    Yamada, T
    Fukunami, M
    Shimonagata, T
    Kumagai, K
    Sanada, S
    Ogita, H
    Asano, Y
    Hoki, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 47A - 47A
  • [26] PRECORDIAL LEAD P-WAVE PATTERNS IN ATRIAL ENLARGEMENT
    ZIEGLER, RF
    CIRCULATION, 1961, 24 (04) : 1077 - &
  • [27] P-wave alternans predicting imminent atrial flutter
    Siniorakis, Eftychios
    Arvanitakis, Spyridon
    Tzevelekos, Panagiotis
    Giannakopoulos, Nikodimos
    Limberi, Sotiria
    CARDIOLOGY JOURNAL, 2017, 24 (06) : 706 - 707
  • [28] P-wave Indices to Detect Susceptibility to Atrial Fibrillation
    Cabasson, A.
    Dang, L.
    Vesin, J. M.
    Buttu, A.
    Abaecherli, R.
    Leber, R.
    Kappenberger, L.
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 257 - 260
  • [29] Effect of transcatheter aortic valve replacement on P-wave duration,P-wave dispersion and left atrial size
    Huseyin Dursun
    Zulkif Tanriverdi
    Tugce Colluoglu
    Dayimi Kaya
    Journal of Geriatric Cardiology, 2015, 12 (06) : 613 - 617
  • [30] Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size
    Dursun, Huseyin
    Tanriverdi, Zulkif
    Colluoglu, Tugce
    Kaya, Dayimi
    JOURNAL OF GERIATRIC CARDIOLOGY, 2015, 12 (06) : 613 - 617