A feasibility study of high dose rate brachytherapy in solitary urinary bladder cancer

被引:7
|
作者
Soete, G [1 ]
Coen, V [1 ]
Verellen, D [1 ]
Keuppens, F [1 ]
DeBoe, V [1 ]
Storme, G [1 ]
机构
[1] FREE UNIV BRUSSELS,ACAD HOSP,DEPT UROL,B-1090 BRUSSELS,BELGIUM
关键词
bladder cancer; brachytherapy; high dose rate;
D O I
10.1016/S0360-3016(97)00063-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the feasibility of high dose rate brachytherapy in the treatment of T1-T3 solitary bladder cancer and to compare results and side-effects to those obtained by others using conventional, i.e., low dose rate regimens. Methods and Materials: Between July 1992 and 1995, 16 patients entered the study. Median age at diagnosis was 64 years (range: 45-79 years). Diagnostic transurethral resection showed four T1, five T2, and seven T3 lesions, all proven solitary by random biopsies. Radiotherapy consisted of low-dose preoperative external beam irradiation (3 x 3.5 Gy on the 3 consecutive days prior to implantation), followed by high dose rate brachytherapy (15 x 3 Gy during the 8 consecutive days thereafter). Median follow-up from the date of implantation was 23 months (range: 6-43 months). In 15 patients, cystoscopy was systematically performed during follow-up, whereas the 16th patient was followed on a clinical basis only. Results: Recurrences have occurred in 2 of 15 evaluable patients (both stage T3): metastasis in 1 and combined local plus distant failure in the other patient. Cystoscopic evaluation showed persisting alterations of the implanted portion of the bladder mucosa in 11 of 15 evaluable patients (ulceration, calcifications, and/or punctiform bleedings). Symptomatic radiation cystitis was mild and transient in 14 but persisting and severe in 2 patients. Conclusion: This study documents the feasibility of high dose rate brachytherapy ire a selected group of bladder cancer patients. Both patient outcome and side-effects are comparable to the best results obtained with low dose rate schedules. Additional follow-up is still needed to enforce the comparison. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:743 / 747
页数:5
相关论文
共 50 条
  • [31] Pilot study of intraoperative high dose rate brachytherapy for head and neck cancer
    Nag, S
    Schuller, D
    Pak, V
    Young, D
    Grecula, J
    Bauer, C
    Samsami, N
    RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) : 125 - 130
  • [32] Implications of bladder volume on target coverage and dose to critical structures during high dose rate intracavitary brachytherapy for cervical cancer: A dosimetric study
    Patel, Rahil B.
    Gururajachar, Janaki Manur
    Revathy, T.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (06) : 1207 - 1211
  • [33] An evaluation of our experience in position verification of catheters used for interstitial high-dose-rate brachytherapy of solitary bladder tumors
    Bus, S. J. E. A.
    Leus, N. G.
    Oosterveld, B. J.
    Van Gellekom, M. P. R.
    van de Loop, G. J. M.
    van der Steen-Banasik, E. M.
    BRACHYTHERAPY, 2018, 17 (01) : 24 - 30
  • [34] Brachytherapy for early oral tongue cancer: Low dose rate to high dose rate
    Yamazaki, H
    Inoue, T
    Yoshida, K
    Yoshioka, Y
    Furukawa, S
    Kakimoto, N
    Shimizutani, K
    Inoue, T
    JOURNAL OF RADIATION RESEARCH, 2003, 44 (01) : 37 - 40
  • [35] Sigmoid dose delivered by high-dose-rate brachytherapy versus low-dose-rate brachytherapy for cervical cancer
    Holloway, C. L.
    O'Farrell, D. A.
    Cormack, R. A.
    Viswanathan, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S165 - S165
  • [36] Feasibility study of patient-specific quality assurance system for high-dose-rate brachytherapy in patients with cervical cancer
    Boram Lee
    Sung Hwan Ahn
    Hyeyoung Kim
    Youngyih Han
    Seung Jae Huh
    Jin Sung Kim
    Dong Wook Kim
    Jina Sim
    Myonggeun Yoon
    Journal of the Korean Physical Society, 2016, 68 : 1029 - 1036
  • [37] Feasibility Study of Patient-specific Quality Assurance System for High-dose-rate Brachytherapy in Patients with Cervical Cancer
    Lee, Boram
    Ahn, Sung Hwan
    Kim, Hyeyoung
    Han, Youngyih
    Huh, Seung Jae
    Kim, Jin Sung
    Kim, Dong Wook
    Sim, Jina
    Yoon, Myonggeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (08) : L1029 - L1036
  • [38] Effect of varying bladder volumes with and without a bladder catheter on dosimetry in high dose rate vaginal vault brachytherapy for endometrial cancer
    Owadally, W. S.
    Fenwick, V.
    Burton, N.
    Hagan, I.
    Cook, A.
    Counsell, R.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S727 - S727
  • [39] Dosimetric characterization and feasibility testing for a new electronic high dose rate brachytherapy
    Rieke, JW
    Zaider, M
    Silvern, DA
    Rusch, TW
    Hansen, SD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S592 - S592
  • [40] Intraosseous High Dose Rate Brachytherapy (HDR) with Intramedullary Nailing for Long Bone Metastases - A Feasibility Study
    Gannavarapu, Bhavani
    Hassan-Rezaeian, Nima
    ONeill, David
    Hrycushko, Brian
    Folkert, Michael
    Callan, Alexandra
    Timmerman, Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (02): : E53 - E53