10-year results of the Birmingham Hip Resurfacing: a non-designer case series

被引:15
|
作者
Hunter, Thomas J. A. [1 ]
Moores, Thomas S. [1 ]
Morley, David [1 ]
Manoharan, Gopikanthan [1 ]
Collier, Simon G. [1 ]
Shaylor, Phillip J. [1 ]
机构
[1] Univ Hosp North Midlands NHS Trust, Stoke On Trent, Staffs, England
关键词
Arthroplasty; Birmingham Hip; Hip; Hip resurfacing; Metal-on-metal; FOLLOW-UP; ARTHROPLASTY; METAL; REVISION; REPLACEMENT; YOUNGER; COHORT;
D O I
10.5301/hipint.5000518
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Recent controversies surrounding metal-on-metal (MoM) hip resurfacing has led to a substantial decline in its use. Despite this, there is good evidence to support the use of specific implants in select patients. Patients and methods: A retrospective analysis of Birmingham Hip Resurfacing (BHR) patients with a minimum of 10 years follow-up was performed. Functional scoring was performed with the Oxford Hip Score (OHS) and failure was defined as revision for any cause. 111 patients underwent 121 BHR procedures. All patients had a minimum follow-up of 10 years. 70 patients (63%) were male. Mean patient age at surgery was 52.5 years (male 53.9 years, female 48.8 years). Results: Overall survival at 10 years was 91% (97% male, 80% female). There was a statistically significant improvement in OHS postoperatively which remains at 10-year follow-up (p = <0.05). There was no significant difference in scores between the male and female groups. Revisions were most often in patients with smaller component sizes but this was not found to be statistically significant. Conclusions: Our results reflect that of the wider literature in that good outcomes can be obtained with this implant in a select group of patients and results are comparable to that of conventional hip arthroplasty in patients of a similar age.
引用
收藏
页码:50 / 52
页数:3
相关论文
共 50 条
  • [1] 10-year results of ReCap hip resurfacing arthroplasty: a non-designer case series
    Kiran, Manish
    Santhapuri, Sunil
    Moeen, Sara
    Merchant, Irfan
    Arvinte, Dan
    Sood, Manoj
    [J]. HIP INTERNATIONAL, 2019, 29 (04) : 393 - 397
  • [2] Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing FROM A SINGLE, NON-DESIGNER SURGEON
    Holland, J. P.
    Langton, D. J.
    Hashmi, M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (04): : 471 - 476
  • [3] The five-year results of the Birmingham hip Resurfacing arthroplasty - An independent series
    Steffen, R. T.
    Pandit, H. P.
    Palan, J.
    Beard, D. J.
    Gundle, R.
    McLardy-Smith, P.
    Murray, D. W.
    Gill, H. S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (04): : 436 - 441
  • [4] Birmingham hip resurfacing: Five to eight year results
    Aleksi Reito
    Timo Puolakka
    Jorma Pajamäki
    [J]. International Orthopaedics, 2011, 35 : 1119 - 1124
  • [5] Birmingham hip resurfacing: Five to eight year results
    Reito, Aleksi
    Puolakka, Timo
    Pajamaki, Jorma
    [J]. INTERNATIONAL ORTHOPAEDICS, 2011, 35 (08) : 1119 - 1124
  • [6] Comparing 1-year and 10-year whole blood metal ion results following Birmingham hip resurfacing for osteoarthritis
    Kearns, Scott J. Watt
    Bourget-Murray, Jonathan
    Johnston, Kelly
    Werle, Jason
    [J]. CANADIAN JOURNAL OF SURGERY, 2022, 65 (04) : E504 - E511
  • [7] The ten-year survival of the Birmingham hip resurfacing AN INDEPENDENT SERIES
    Murray, D. W.
    Grammatopoulos, G.
    Pandit, H.
    Gundle, R.
    Gill, H. S.
    McLardy-Smith, P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (09): : 1180 - 1186
  • [8] Minimum 10-Year Survivorship of Mobile-Bearing Unicompartmental Arthroplasty: Single Surgeon, North American Non-Designer Consecutive Series
    Carlson, Samuel W.
    Lu, Yining
    Sierra, Rafael J.
    [J]. JOURNAL OF ARTHROPLASTY, 2022, 37 (06): : S88 - S93
  • [9] Midterm results of the Birmingham hip resurfacing: a single-surgeon series
    Richard Lass
    Ulrich Bechler
    Bernhard Springer
    Kilian Rueckl
    Carola Hanreich
    Friedrich Boettner
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 1041 - 1048
  • [10] Midterm results of the Birmingham hip resurfacing: a single-surgeon series
    Lass, Richard
    Bechler, Ulrich
    Springer, Bernhard
    Rueckl, Kilian
    Hanreich, Carola
    Boettner, Friedrich
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (02) : 1041 - 1048