Dual enzymatic biosensor for simultaneous amperometric determination of histamine and putrescine

被引:59
|
作者
Henao-Escobar, W. [1 ]
del Torno-de Roman, L. [1 ]
Dominguez-Renedo, O. [1 ]
Alonso-Lomillo, M. A. [1 ]
Arcos-Martinez, M. J. [1 ]
机构
[1] Univ Burgos, Dept Analyt Chem, Fac Sci, Burgos 09001, Spain
关键词
Dual enzymatic biosensor; Histamine; Putrescine; Screen-printed electrodes; Simultaneous determination; PRINTED CARBON ELECTRODES; BIOGENIC-AMINES; ACID DETERMINATION; DIAMINE OXIDASE; WINES; FOOD;
D O I
10.1016/j.foodchem.2015.06.035
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A disposable electrodic system consisting of two working electrodes connected in array mode has been developed for the simultaneous determination of histamine (His) and putrescine (Put). Histamine deshydrogenase and putrescine oxidase enzymes were respectively immobilized by crosslinking on each working screen-printed electrode, both modified with tetrathiafulvalene. The dual system allowed the simultaneous amperometric determination of both species by measuring the oxidation current of the mediator in each working electrode. The effect of other potentially interfering biogenic amines was also evaluated. The capability of detection was of 8.1 +/- 0.7 for His and 10 +/- 0.6 mu M for Put. The precision in terms of relative standard deviation was of 3.5% and 6.7% for His and Put, respectively. The developed biosensor was successfully applied to the determination of His and Put in different food samples. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 50 条
  • [31] An amperometric biosensor for the determination of organophosphorus pesticides
    Telefoncu, A
    [J]. TURKISH JOURNAL OF CHEMISTRY, 1996, 20 (03): : 253 - 257
  • [32] Amperometric inhibition biosensor for the determination of cyanide
    Ghanavati, Mahdi
    Azad, Reza Roosta
    Mousavi, Seyyed Abbas
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 858 - 864
  • [33] A reagentless biosensor for the amperometric determination of NADH
    Cosnier, S
    Decout, JL
    Fontecave, M
    Frier, C
    Innocent, C
    [J]. ELECTROANALYSIS, 1998, 10 (08) : 521 - 525
  • [34] Amperometric Acetylcholinesterase Biosensor for Physostigmine Determination
    Davletshina, R. R.
    Ivanov, A. N.
    Evtugyn, G. A.
    [J]. UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2018, 160 (01): : 5 - 16
  • [35] Mediated Amperometric Biosensor for the Determination of Ammonium
    Abd Rahman, Samsulida
    Abdullah, Jaafar
    Sidek, Hamidah
    Azmi, Nur Ellina
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (03): : 262 - 276
  • [36] Development and study of an amperometric biosensor for the in vitro measurement of low concentration of putrescine in blood
    Nagy, L
    Nagy, G
    Gyurcsányi, RE
    Neuman, MR
    Lindner, E
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 53 (1-3): : 165 - 175
  • [37] A FLOW-INJECTION BIOSENSOR SYSTEM FOR THE AMPEROMETRIC DETERMINATION OF CREATININE - SIMULTANEOUS COMPENSATION OF ENDOGENOUS INTERFERENTS
    RUI, CS
    SONOMOTO, K
    OGAWA, HI
    KATO, Y
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 210 (01) : 163 - 171
  • [38] Enzyme Based Amperometric Biosensor for Adenine Determination
    Boka, Beata
    Adanyi, Nora
    Virag, Diana
    Frebort, Ivo
    Kiss, Attila
    [J]. ELECTROANALYSIS, 2013, 25 (01) : 237 - 242
  • [39] Amperometric determination of fish freshness by a hypoxanthine biosensor
    Shen, LQ
    Yang, LJ
    Peng, TZ
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1996, 70 (03) : 298 - 302
  • [40] An amperometric biosensor array for precise determination of homocysteine
    Ching, Congo Tak-Shing
    Chang, Jen-Wei
    Sun, Tai-Ping
    Shieh, Hsiu-Li
    Tsai, Chun-Lang
    Huang, Hsin-Wei
    Liu, Wei-Hao
    Liu, Chia-Ming
    Yeh, Wei-Chung
    Li, Jia-Hao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 152 (01) : 94 - 98