Comparison of photoacoustic image reconstruction algorithms using the channelized Hotelling observer

被引:10
|
作者
Petschke, Adam [1 ]
La Riviere, Patrick J. [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
photoacoustic imaging; image reconstruction; channelized Hotelling observer; filtered backprojection; pseudoinverse; singular-value decomposition; Fourier-based reconstruction; medical imaging; biological imaging; REAL-TIME; TOMOGRAPHY; SYSTEM;
D O I
10.1117/1.JBO.18.2.026009
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We demonstrate the use of task-based image-quality metrics to compare various photoacoustic image-reconstruction algorithms, including a method based on the pseudoinverse of the system matrix, simple backprojection, filtered backprojection, and a method based on the Fourier transform. We use a three-dimensional forward model with a linear transducer array to simulate a photoacoustic imaging system. The reconstructed images correspond with two-dimensional slices of the object and are 128 x 128 pixels. In order to compare the algorithms, we use channelized Hotelling observers that predict the detection ability of human observers. We use two sets of channels: constant Q and difference of Gaussian spatial frequency channels. We look at three tasks, identification of a point source in a uniform background, identification of a 0.5-mm cube in a uniform background, and identification of a point source in a lumpy background. For the lumpy background task, which is the most realistic of the tasks, the method based on the pseudoinverse performs best according to both sets of channels. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.18.2.026009]
引用
收藏
页数:6
相关论文
共 50 条
  • [21] CHARACTERIZATION OF TWO CT SYSTEMS USING A CHANNELIZED HOTELLING OBSERVER AND NPS METRIC
    Ortenzia, O.
    D'Alessio, A.
    Noferini, L.
    Ghetti, C.
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (02) : 224 - 233
  • [22] Diagnosis of Parkinsonian disorders using a channelized Hotelling observer model: Proof of principle
    Bal, H.
    Bal, G.
    Acton, P. D.
    MEDICAL PHYSICS, 2007, 34 (10) : 3987 - 3995
  • [23] Validation of a Channelized Hotelling Observer to Optimize Chest Radiography Image Processing for Nodule Detection: A Human Observer Study
    Sanchez, A.
    Little, K.
    Chung, J.
    Lu, Z. F.
    MacMahon, H.
    Reiser, I.
    MEDICAL PHYSICS, 2016, 43 (06) : 3763 - 3763
  • [24] Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms
    Yu, Lifeng
    Leng, Shuai
    Chen, Lingyun
    Kofler, James M.
    Carter, Rickey E.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [25] Real space channelization for generic DBT system image quality evaluation with channelized Hotelling observer
    Petrov, Dimitar
    Cockmartin, Lesley
    Marshall, Nicholas
    Vancoillie, Liesbeth
    Young, Kenneth
    Bosmansa, Hilde
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [26] Accurate computation of the Hotelling observer for the evaluation of image reconstruction algorithms in helical, cone-beam CT
    Sidky, Emil Y.
    LaRoque, Samuel J.
    Pan, Xiaochuan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3233 - 3236
  • [27] Optimization of [I-123]mIBG Imaging using a Channelized-Hotelling Observer
    Gregory, R. A.
    Murray, I.
    Gear, J.
    Aldridge, M. D.
    Waddington, W. A.
    Chua, S.
    Flux, G. D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S232 - S232
  • [28] Evaluation of 3D reconstruction methods for reduced acquisition time using channelized Hotelling observer for myocardial perfusion SPECT
    Lee, Taek-Soo
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [29] Deep learning channelized Hotelling observer for multi-vendor DBT system image quality evaluation
    Petrov, Dimitar
    Marshall, Nicholas
    Vancoillie, Liesbeth
    Cockmartin, Lesley
    Bosmans, Hilde
    MEDICAL IMAGING 2020: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2020, 11316
  • [30] Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems
    Favazza, Christopher P.
    Fetterly, Kenneth A.
    Hangiandreou, Nicholas J.
    Leng, Shuai
    Schueler, Beth A.
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (01)