摘要
Objectives: This study was conducted to determine if significant differences existed between the fracture toughness of three types of luting cement, and, if the method of mixing conventional glass-ionomer luting cements, hand-mixed or mechanically mixed, influenced the value obtained. Methods: Three types of luting cement were investigated: conventional glass-ionomer cement (two handmixed and two capsulated cements, KetacCem, Fuji I and KetacCem Maxicap, Fuji Cap I), a resin-modified glass-ionomer cement (Vitremer Luting Cement) and a resin composite cement (Scotchbond Resin Cement). Eleven specimens of each of the six cements were fabricated to determine the plane strain fracture toughness using the chevron notch short rod technique. After seven days the specimens were loaded in a water bath, at a crosshead speed of 4 mu m/s and the fracture toughness values calculated. Results: ANOVA indicated significant differences between the cements (p < 0.0001) and each cement was compared with all others using Fishers PSLD test (p < 0.05). The rank order of results from highest fracture toughness value to lowest (mean +/- s.d.) was Scotchbond Resin Cement (1.31 +/- 0.17), Vitremer Luting Cement (1.08 +/- 0.1), Fuji Cap I (0.37 +/- 0.04), KetacCem Maxicap (0.37 +/- 0.05), Fuji I (0.34 +/- 0.04), KetacCem (0.27 +/- 0.03). Significance: Of the cements tested, the resin composite cement is most likely to resist clinical failure by cement cohesive failure. (C) 1999 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [31] Properties of conventional and resin modified glass ionomer luting cements.
    Brassesco, MB
    Edelberg, MH
    Zurdo, G
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 930 - 930
  • [32] Water sorption characteristics of resin-modified glass-ionomer cements.
    Kanchanavasita, W
    Pearson, GJ
    Anstice, HM
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 422 - 422
  • [33] The physics of water sorption by resin-modified glass-ionomer dental cements
    J. W NICHOLSON
    Journal of Materials Science: Materials in Medicine, 1997, 8 : 691 - 695
  • [34] Variability in cytotoxicity and fluoride release of resin-modified glass-ionomer cements
    Kan, KC
    Messer, LB
    Messer, HH
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (08) : 1502 - 1507
  • [35] Fracture toughness of glass-ionomer cements.
    Kakuta, K
    Hood, JA
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1132 - 1132
  • [36] Comparison of zirconia to dentin bonding using resin-based luting cements and resin-modified glass-ionomer cement: In vitro
    Vivek, V. J.
    Venugopal, P.
    Divakar, Namitha
    Bharath, Subin
    Sarin, K.
    Mohammed, Nasrin
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 460 - 463
  • [37] An In Vitro Biocompatibility Study of Conventional and Resin-modified Glass Ionomer Cements
    Rodriguez, Ismael A.
    Rozas Ferrara, Carlos A.
    Campos-Sanchez, Fernando
    Alaminos, Miguel
    Uribe Echevarria, Jorge
    Campos, Antonio
    JOURNAL OF ADHESIVE DENTISTRY, 2013, 15 (06): : 541 - 546
  • [38] Effectiveness of surface protection for glass-ionomer, resin-modified glass-ionomer and polyacid-modified composite resins
    Karaoglanoglu, Serpil
    Akgul, Nilgun
    Ozdabak, Hatice Nur
    Akgul, Hayati Murat
    DENTAL MATERIALS JOURNAL, 2009, 28 (01) : 96 - 101
  • [39] Long-term flexural strengths of resin-modified glass-ionomer cements
    Biomaterials Department, Eastman Dental Institute, 256 Gray's Inn Road, London WC1X 8LD, United Kingdom
    Biomaterials, 18 (1703-1713):
  • [40] Alternative Methacrylate-Tethering Methods for Resin-Modified Glass-Ionomer Cements
    Xie, Dong
    Weng, Yiming
    Zhao, Jun
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 111 (02) : 869 - 875