DESIGN AND PRELIMINARY EXPERIMENTS OF A PRECISION MICROWAVE TOMOGRAPHY SYSTEM

被引:1
|
作者
Kim, Jang-Yeol [1 ]
Lee, Kwang-Jae [1 ]
Son, Seong-Ho [1 ]
Lee, Jong-Moon [1 ]
Kim, Hyuk-Je [1 ]
Kim, Bo-Ra [1 ]
Simonov, Nikolai [1 ]
Jeon, Soon-Ik [1 ]
Kim, Nam [2 ]
机构
[1] Elect & Telecommun Res Inst, Radio Technol Res Dept, Taejon 305606, South Korea
[2] Chungbuk Natl Univ, Sch Informat & Commun Engn, Cheongju, Chungbuk, South Korea
关键词
microwave tomography; phantom; measurement data; image reconstruction; BREAST-CANCER DETECTION; PROTOTYPE;
D O I
10.1002/mop.29347
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article presents the image reconstruction results of measurement data from a preliminary test using the first-developed precision microwave tomography (MT) system operating at 3-6 GHz for medical diagnosis. A simple phantom is used in the MT system to verify the data validation. The measurement dataset has very different patterns owing to the significant contrast of dielectric properties according to the existence of a phantom in the sensing area of the illumination tank at microwave frequencies. Thus, it is possible to obtain the image reconstruction from this measurement data. The detailed results are presented and discussed. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:2445 / 2448
页数:5
相关论文
共 50 条
  • [31] Investigation of Spatial Resolution in a Microwave Tomography System
    Simonov, Nikolai
    Son, Seong-Ho
    Kim, Bo-Ra
    Jeon, Soon-Ik
    2014 International Conference on Electronics, Information and Communications (ICEIC), 2014,
  • [32] Quantum process tomography via optimal design of experiments
    Gazit, Yonatan
    Ng, Hui Khoon
    Suzuki, Jun
    PHYSICAL REVIEW A, 2019, 100 (01)
  • [33] Bayesian approach to the design of chemical species tomography experiments
    Grauer, Samuel J.
    Hadwin, Paul J.
    Daun, Kyle J.
    APPLIED OPTICS, 2016, 55 (21) : 5772 - 5782
  • [34] A NEW TECHNIQUE FOR THE PRECISION DME OF MICROWAVE LANDING SYSTEM
    CHIARINI, F
    GORI, M
    VATALARO, F
    CORAZZA, G
    FALCIASECCA, G
    ALTA FREQUENZA, 1982, 51 (05): : 242 - 256
  • [35] Preliminary Evaluation of Geopolymer Mix Design Applying the Design of Experiments Method
    Callai, Sergio Copetti
    Tataranni, Piergiorgio
    Sangiorgi, Cesare
    INFRASTRUCTURES, 2021, 6 (03)
  • [36] Design and Implementation of a High-precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging
    Shi, Xuetao
    You, Fusheng
    Xu, Canhua
    Ji, Zhenyu
    Liu, Ruigang
    Dong, Xiuzhen
    Fu, Feng
    Huo, Xuyang
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 9 - 13
  • [37] PRECISION DISTANCE MEASURING EQUIPMENT FOR THE MICROWAVE LANDING SYSTEM
    BECKER, K
    MULLER, A
    VOGEL, H
    ELECTRICAL COMMUNICATION, 1984, 58 (03): : 336 - 343
  • [38] Optimal Design of Experiments for Precision Agriculture Using a Genetic Algorithm
    Peerlinck, Amy
    Sheppard, John
    Pastorino, Julie
    Maxwell, Bruce
    2019 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2019, : 1838 - 1845
  • [39] Profile-based Sensitivity in the Design of Experiments for Parameter Precision
    Sulieman, Hana
    2013 5TH INTERNATIONAL CONFERENCE ON MODELING, SIMULATION AND APPLIED OPTIMIZATION (ICMSAO), 2013,
  • [40] PRELIMINARY EXPERIMENTS ON KEYBOARD DESIGN FOR SEMIAUTOMATIC MAIL SORTING
    BOWEN, HM
    GUINNESS, GV
    JOURNAL OF APPLIED PSYCHOLOGY, 1965, 49 (03) : 194 - 198