A review of cone-beam CT applications for adaptive radiotherapy of prostate cancer

被引:56
|
作者
Posiewnik, M. [1 ]
Piotrowski, T. [2 ,3 ]
机构
[1] Gdynia Oncol Ctr, Dept Med Phys, Gdynia, Poland
[2] Poznan Univ Med Sci, Dept Electroradiol, Poznan, Poland
[3] Greater Poland Canc Ctr, Dept Med Phys, Poznan, Poland
关键词
IGRT; Adaptive radiotherapy; Cone-beam CT; Prostate cancer; IMAGE-GUIDED RADIOTHERAPY; QUALITY-ASSURANCE PROGRAM; ONLINE RE-OPTIMIZATION; COMPUTED-TOMOGRAPHY; GUIDANCE STRATEGIES; DOSE DISTRIBUTION; FIDUCIAL MARKERS; RECTAL DIAMETER; IMRT PLANS; CBCT;
D O I
10.1016/j.ejmp.2019.02.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to systematize the information on adaptive radiotherapy based on cone-beam computed tomography (CBCT) imaging for patients with prostate cancers including the prostate gland only, or the prostate gland and seminal vesicles region. Material and method: A systematic literature search was carried out using the PubMed engine, based upon the following terms: adaptive radiotherapy, intensity modulated radiotherapy, volumetric modulated arc therapy and image-guided and dose-guided radiotherapy. Overall, 58 relevant studies were included: 31 about on-line strategies of adaptation, 6 about off-line strategies, and 21 that highlighted the technical aspects of CBCT usage. Results: The off-line strategies provide a statistical prediction for each individual patient for the rest of treatment. The on-line strategies aim to resolve the potential disagreements between a planned and delivered dose directly before the specific fraction. Both strategies need information about the movements of the irradiated region relative to the target from treatment planning and the dose delivered relative to the planned dose. Quality of CBCT is very important for the accuracy of the adaptation procedures. While the errors caused by the insufficient quality of anatomy visualisation with CBCT are currently minimized, there are still problems with the proper dose computation. The most accurate methods are able to minimize the calculation error to 3%. Conclusion: CBCT plays a significant role in each step of adaptive radiation therapy of prostate cancers, starting from registration procedures through setting an appropriate CTV-to-PTV margin to fraction dose recalculations, and its cumulation/monitoring relative to the planned dose.
引用
下载
收藏
页码:13 / 21
页数:9
相关论文
共 50 条
  • [21] Cone-beam CT-based adaptive planning or filling protocol for neoadjuvant gastric cancer radiotherapy
    Schuster, H.
    Boda-Heggemann, J.
    Jahnke, L.
    Buergy, D.
    Wenz, F.
    Siebenlist, K.
    Giordano, F. A.
    Jahnke, A.
    Sarria, G.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S894 - S895
  • [22] Daily Artificial Intelligence-Assisted Adaptive Radiotherapy on Cone-Beam CT for Cancer of the Head and Neck
    Blumenfeld, P. A.
    Feldman, J.
    Arbit, E.
    Weizman, N.
    Berger, A.
    Hillman, Y.
    Wygoda, M. R.
    Popovtzer, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E590 - E591
  • [23] Interfraction variation in prostate cancer - analysis of 11726 cone-beam CT
    Dolezel, Martin
    Slezak, Peter
    Odrazka, Karel
    Vanasek, Jaroslav
    Hlavka, Ales
    Ulrych, Vit
    Stuk, Jan
    Waczulikova, Iveta
    Hartmann, Igor
    JOURNAL OF BUON, 2015, 20 (04): : 1081 - 1087
  • [24] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [25] CORRECTION STRATEGIES FOR CONE-BEAM CT GUIDED RADIOTHERAPY
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S141 - S142
  • [26] Clinical implementation of cone-beam CT guided radiotherapy
    van Herk, M
    Jaffray, D
    Remeijer, P
    Sonke, JJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S17 - S17
  • [27] Hypofractionated online image-guided radiotherapy (IGRT) via cone-beam CT (CBCT) for prostate cancer
    Kestin, L.
    Yan, D.
    Ghilezan, M.
    Wu, Q.
    Wloch, J.
    Vicini, F.
    Martinez, A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S169 - S169
  • [28] Is it essential to use fiducial markers during cone-beam CT-based radiotherapy for prostate cancer patients?
    Yildirim, Berna A.
    Onal, Cem
    Dolek, Yemliha
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (01) : 3 - 9
  • [29] Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy
    Guan, Huaiqun
    Dong, Hang
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6239 - 6250
  • [30] Is it essential to use fiducial markers during cone-beam CT-based radiotherapy for prostate cancer patients?
    Berna A. Yildirim
    Cem Onal
    Yemliha Dolek
    Japanese Journal of Radiology, 2017, 35 : 3 - 9