Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults

被引:62
|
作者
Van Lummel, R. C. [1 ]
Ainsworth, E. [1 ]
Lindemann, U. [2 ]
Zijlstra, W. [3 ]
Chiari, L. [4 ]
Van Campen, P. [5 ]
Hausdorff, J. M. [6 ,7 ]
机构
[1] McRoberts, NL-2596 HN The Hague, Netherlands
[2] Robert Bosch Krankenhaus, Dept Clin Gerontol, D-70376 Stuttgart, Germany
[3] Univ Groningen, Univ Med Ctr Groningen, Ctr Human Movement Sci, NL-9700 AD Groningen, Netherlands
[4] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
[5] Van Campen Physiotherapy, The Hague, Netherlands
[6] Tel Aviv Univ, Dept Neurol, Tel Aviv Sourasky Med Ctr, Lab Gait & Neurodynam,Movement Disorders Unit, IL-64239 Tel Aviv, Israel
[7] Tel Aviv Univ, Sackler Fac Med, Dept Phys Therapy, IL-64239 Tel Aviv, Israel
关键词
Sit-to-stand; Body fixed sensors; Accelerometers; Gyroscopes; Automated analyses; Older adults; ACCELEROMETERS; CHAIR;
D O I
10.1016/j.gaitpost.2012.10.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Much is known about the sit-to-stand (STS) and its biomechanics. Currently, however, there is little opportunity for instrumented quantification of the STS as part of screening or diagnosis in clinical practice. The objectives of the present study were to describe the feasibility of using an automated approach for quantifying the STS using one sensor location and to start testing the discriminative validity of this approach by comparing older and younger adults. 15 older subjects recruited from a residential care home and 16 young adults performed 5 repeated sit-to-stand and stand-to-sit movements. They were instrumented with a small and lightweight measurement system (DynaPort (R)) containing 1 triaxial seismic accelerometer and 3 uniaxial gyroscopes fixed in a belt around the waist. Durations of the (sub-)phases of the STS were analyzed and maximum angular velocities were determined. All successful STS cycles were automatically detected without any errors. The STS duration in the older adults was significantly longer and more variable in all phases (i.e., sit-to-stand, standing, stand-to-sit and sitting) compared to the young adults. Older adults also exhibited lower trunk flexion angular velocity. The results of this first fully automated analysis of instrumented repeated STS movements demonstrate that several STS parameters can be identified that provide a basis for a more precise, quantitative study of STS performance in clinical practice. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 156
页数:4
相关论文
共 30 条
  • [21] Estimation of Functional Aerobic Capacity Using the Sit-to-Stand Test in Older Adults with Heart Failure with Preserved Ejection Fraction
    Jose Fuentes-Abolafio, Ivan
    Escriche-Escuder, Adrian
    Rosa Bernal-Lopez, Maria
    Gomez-Huelgas, Ricardo
    Ricci, Michele
    Trinidad-Fernandez, Manuel
    Roldan-Jimenez, Cristina
    Maria Arjona-Caballero, Jose
    Ignacio Cuesta-Vargas, Antonio
    Miguel Perez-Belmonte, Luis
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
  • [22] Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults
    Regterschot, G. Ruben H.
    Folkersma, Marjanne
    Zhang, Wei
    Baldus, Heribert
    Stevens, Martin
    Zijlstra, Wiebren
    [J]. GAIT & POSTURE, 2014, 39 (01) : 303 - 307
  • [23] Sensor-based monitoring of sit-to-stand performance is indicative of objective and self-reported aspects of functional status in older adults
    Regterschot, G. Ruben H.
    Zhang, Wei
    Baldus, Heribert
    Stevens, Martin
    Zijlstra, Wiebren
    [J]. GAIT & POSTURE, 2015, 41 (04) : 935 - 940
  • [24] Clinimetric properties of the one-leg sit-to-stand test in examining unilateral lower limb muscle strength among young adults
    Thongchoomsin, Surachart
    Bovonsunthonchai, Sunee
    Joseph, Leonard
    Chamnongkich, Samatchai
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2020, 74 (09)
  • [25] Using Mobile Technology to Assess Balance During a Sit-to-Stand Maneuver Among Older Adults With Fall Risk A Pilot Study
    Gray-Miceli, Deanna
    Patel, Neel
    Sekar, Akshaya
    Smith, Matthew Lee
    [J]. JOURNAL OF GERONTOLOGICAL NURSING, 2019, 45 (10): : 18 - 23
  • [26] Effects of seat height on whole-body movement and lower limb muscle power during sit-to-stand movements in young and older individuals
    Honda, Keita
    Sekiguchi, Yusuke
    Sasaki, Akiko
    Shimazaki, Satoko
    Suzuki, Rie
    Suzuki, Takahiro
    Kanetaka, Hiroyasu
    Izumi, Shin-Ichi
    [J]. JOURNAL OF BIOMECHANICS, 2021, 129
  • [27] A body-fixed-sensor-based analysis of stair ascent and sit-to-stand to detect age-related differences in leg-extensor power
    Van Roie, Evelien
    Van Driessche, Stijn
    Huijben, Bas
    Baggen, Remco
    van Lummel, Rob C.
    Delecluse, Christophe
    [J]. PLOS ONE, 2019, 14 (01):
  • [28] Whole-body vibration training improves balance control and sit-to-stand performance among middle-aged and older adults: a pilot randomized controlled trial
    Ming-Chen Ko
    Long-Shan Wu
    Sangwoo Lee
    Chien-Chun Wang
    Po-Fu Lee
    Ching-Yu Tseng
    Chien-Chang Ho
    [J]. European Review of Aging and Physical Activity, 2017, 14
  • [29] Whole-body vibration training improves balance control and sit-to-stand performance among middle-aged and older adults: a pilot randomized controlled trial
    Ko, Ming-Chen
    Wu, Long-Shan
    Lee, Sangwoo
    Wang, Chien-Chun
    Lee, Po-Fu
    Tseng, Ching-Yu
    Ho, Chien-Chang
    [J]. EUROPEAN REVIEW OF AGING AND PHYSICAL ACTIVITY, 2017, 14
  • [30] Using a Body-Fixed Sensor to Identify Subclinical Gait Difficulties in Older Adults with IADL Disability: Maximizing the Output of the Timed Up and Go
    Weiss, Aner
    Mirelman, Anat
    Buchman, Aron S.
    Bennett, David A.
    Hausdorff, Jeffrey M.
    [J]. PLOS ONE, 2013, 8 (07):