Possible Influences on the Interpretation of Functional Domain (FD) Near-Infrared Spectroscopy (NIRS): An Explorative Study

被引:6
|
作者
Celie, Bert M. [1 ]
Boone, Jan [1 ,2 ]
Dumortier, Jasmien [1 ]
Derave, Wim [1 ]
De Backer, Tine [3 ]
Bourgois, Jan G. [1 ,2 ]
机构
[1] Univ Ghent, Dept Movement & Sports Sci, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Ctr Sports Med, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Cardiol, Ghent, Belgium
关键词
Near-infrared spectroscopy; NIRS; Subcutaneous adipose tissue thickness; ATT; Blood flow; Physiological calibration; FEMORAL BLOOD-GASES; MUSCLE DEOXYGENATION; INCREMENTAL HANDGRIP; UPTAKE KINETICS; SKELETAL; OXYGENATION; EXERCISE; FLOW; LEG; VASODILATATION;
D O I
10.1177/0003702815620562
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The influence of subcutaneous adipose tissue (ATT) and oxygen (O-2) delivery has been poorly defined in frequency domain (FD) near-infrared spectroscopy (NIRS). Therefore, the aim of this study was to investigate the possible influence of these variables on all FD NIRS responses using a reliable protocol. Moreover, these influences were also investigated when using relative oxy- and deoxyhemoglobin and -myoglobin (oxy[Hb+Mb] and deoxy[Hb+Mb]) values (in %). A regression analysis was carried out for ATT and maximal-minimum oxy[Hb+Mb], deoxy[Hb+Mb], oxygen saturation (SmO2), and total hemoglobin (totHb) amplitudes during an incremental cyclic contraction protocol (ICCP) in a group of 45 participants. Moreover, the same analysis was carried out between subcutaneous ATT and the relative oxy- and deoxy[Hb+Mb] values (in %). In the second part of this study, a regression analysis was performed for peak forearm blood flow (FBF) during ICCP and the absolute and relative NIRS values in a group of 37 participants. Significant exponential correlation coefficients were found between ATT and deoxy[Hb+Mb] (r = 0.53; P<0.001), oxy[Hb+Mb] (r = 0.57; P<0.001), and SmO2 amplitudes (r = 0.57; P<0.001). No significant relations were found between ATT and relative oxy[Hb+Mb] (r = 0.37; P = 0.07) and deoxy[Hb+Mb] (r = 0.09; P = 0.82). Significant positive correlation coefficients were found between force at exhaustion and maximal FBF (r = 0.66; P<0.001), maximal differences in deoxy[Hb+Mb] (r = 0.353; P = 0.032) and totHb (r = 0.512; P = 0.002) while no significant correlation coefficients were found between these maximal force values and maximal differences in oxy[Hb+Mb] (r = -0.267; P = 0.111) and SmO2 (r = -0.267; P = 0.111). Significant linear correlation coefficients were found between FBF and deoxy[Hb+Mb] (r = 0.51; P = 0.001), oxy[Hb+Mb] (r = -0.50; P = 0.001), SmO2 (r = -0.54; P = 0.001), and totHb amplitude (r = 0.61; P<0.001). No significant correlations were found when using relative oxy[Hb+Mb] (r = -0.01; P = 0.957) and deoxy[Hb+Mb] (r = -0.02; P = 0.895). Based on these findings, caution is advised when using NIRS values, as subcutaneous ATT and O-2 delivery significantly influence NIRS measurements. To eliminate these influences, use of relative deoxy[Hb+Mb] is advised, especially in clinical settings or in people with a higher subcutaneous ATT layer.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [41] Use of near-infrared spectroscopy (NIRS) during carotid endarterectomy (CEA)
    Amory, DW
    Chen, B
    Benni, P
    Hardman, D
    McCann, RL
    ANESTHESIA AND ANALGESIA, 1998, 86 (04): : SCA86 - SCA86
  • [42] Near-infrared spectroscopy (NIRS) reflectance technology for the determination of tocopherols in alfalfa
    I. González-Martín
    J. M. Hernández-Hierro
    M. Bustamante-Rangel
    N. Barros-Ferreiro
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1553 - 1558
  • [43] Use of near-infrared reflectance spectroscopy (NIRS) in palaeoecological studies of peat
    McTiernan, KB
    Garnett, MH
    Mauquoy, D
    Ineson, P
    Couteaux, MM
    HOLOCENE, 1998, 8 (06): : 729 - 740
  • [44] Characterization of the Freshness of Pork by Near-Infrared Spectroscopy (NIRS) and Ensemble Learning
    Tan, Cheng
    Chen, Hui
    Zeng, Miao
    Xue, Zhi
    ANALYTICAL LETTERS, 2024,
  • [45] Crop/weed discrimination using near-infrared reflectance spectroscopy (NIRS)
    Zhang, Yun
    He, Yong
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, PTS 1 AND 2, 2006, 6047
  • [46] Near-infrared spectroscopy (NIRS) reflectance technology for the determination of tocopherols in alfalfa
    Gonzalez-Martin, I.
    Hernandez-Hierro, J. M.
    Bustamante-Rangel, M.
    Barros-Ferreiro, N.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) : 1553 - 1558
  • [47] Transabdominal fetal pulse oximetry using near-infrared spectroscopy (NIRS)
    Vintzileos, A
    Nioka, S
    Lake, M
    Li, PC
    Luo, QM
    Wang, HM
    Rosen, H
    Chance, B
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S179 - S179
  • [48] Brain auditory activation measured by near-infrared spectroscopy (NIRS) in neonates
    Zaramella, P
    Freato, F
    Amigoni, A
    Salvadori, S
    Marangoni, P
    Suppjei, A
    Schiavo, B
    Chiandetti, L
    PEDIATRIC RESEARCH, 2001, 49 (02) : 213 - 219
  • [49] NEAR-INFRARED SPECTROSCOPY (NIRS) CAN MONITOR REGIONAL TISSUE OXYGENATION
    VALLET, B
    GUERY, B
    MANGALABOYI, J
    CHOPIN, C
    DUPUIS, B
    SCHERPEREEL, P
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 26 - 26
  • [50] Brain auditory activation measured by near-infrared spectroscopy (Nirs) in neonates
    Zaramella, P
    Freato, F
    Salvadori, S
    Marangoni, P
    Simbi, K