Possible Influences on the Interpretation of Functional Domain (FD) Near-Infrared Spectroscopy (NIRS): An Explorative Study

被引:6
|
作者
Celie, Bert M. [1 ]
Boone, Jan [1 ,2 ]
Dumortier, Jasmien [1 ]
Derave, Wim [1 ]
De Backer, Tine [3 ]
Bourgois, Jan G. [1 ,2 ]
机构
[1] Univ Ghent, Dept Movement & Sports Sci, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Ctr Sports Med, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Cardiol, Ghent, Belgium
关键词
Near-infrared spectroscopy; NIRS; Subcutaneous adipose tissue thickness; ATT; Blood flow; Physiological calibration; FEMORAL BLOOD-GASES; MUSCLE DEOXYGENATION; INCREMENTAL HANDGRIP; UPTAKE KINETICS; SKELETAL; OXYGENATION; EXERCISE; FLOW; LEG; VASODILATATION;
D O I
10.1177/0003702815620562
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The influence of subcutaneous adipose tissue (ATT) and oxygen (O-2) delivery has been poorly defined in frequency domain (FD) near-infrared spectroscopy (NIRS). Therefore, the aim of this study was to investigate the possible influence of these variables on all FD NIRS responses using a reliable protocol. Moreover, these influences were also investigated when using relative oxy- and deoxyhemoglobin and -myoglobin (oxy[Hb+Mb] and deoxy[Hb+Mb]) values (in %). A regression analysis was carried out for ATT and maximal-minimum oxy[Hb+Mb], deoxy[Hb+Mb], oxygen saturation (SmO2), and total hemoglobin (totHb) amplitudes during an incremental cyclic contraction protocol (ICCP) in a group of 45 participants. Moreover, the same analysis was carried out between subcutaneous ATT and the relative oxy- and deoxy[Hb+Mb] values (in %). In the second part of this study, a regression analysis was performed for peak forearm blood flow (FBF) during ICCP and the absolute and relative NIRS values in a group of 37 participants. Significant exponential correlation coefficients were found between ATT and deoxy[Hb+Mb] (r = 0.53; P<0.001), oxy[Hb+Mb] (r = 0.57; P<0.001), and SmO2 amplitudes (r = 0.57; P<0.001). No significant relations were found between ATT and relative oxy[Hb+Mb] (r = 0.37; P = 0.07) and deoxy[Hb+Mb] (r = 0.09; P = 0.82). Significant positive correlation coefficients were found between force at exhaustion and maximal FBF (r = 0.66; P<0.001), maximal differences in deoxy[Hb+Mb] (r = 0.353; P = 0.032) and totHb (r = 0.512; P = 0.002) while no significant correlation coefficients were found between these maximal force values and maximal differences in oxy[Hb+Mb] (r = -0.267; P = 0.111) and SmO2 (r = -0.267; P = 0.111). Significant linear correlation coefficients were found between FBF and deoxy[Hb+Mb] (r = 0.51; P = 0.001), oxy[Hb+Mb] (r = -0.50; P = 0.001), SmO2 (r = -0.54; P = 0.001), and totHb amplitude (r = 0.61; P<0.001). No significant correlations were found when using relative oxy[Hb+Mb] (r = -0.01; P = 0.957) and deoxy[Hb+Mb] (r = -0.02; P = 0.895). Based on these findings, caution is advised when using NIRS values, as subcutaneous ATT and O-2 delivery significantly influence NIRS measurements. To eliminate these influences, use of relative deoxy[Hb+Mb] is advised, especially in clinical settings or in people with a higher subcutaneous ATT layer.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [1] Near-infrared spectroscopy (NIRS) in functional research of prefrontal cortex
    Masataka, Nobuo
    Perlovsky, Leonid
    Hiraki, Kazuo
    FRONTIERS IN HUMAN NEUROSCIENCE, 2015, 9
  • [2] NEAR-INFRARED SPECTROSCOPY (NIRS) FOR APPLICATION IN UROLOGY
    Te, Alexis E.
    Chung, Doreen E.
    Lee, Richard I.
    Kaplan, Steven A.
    JOURNAL OF UROLOGY, 2009, 181 (04): : 601 - 602
  • [3] Quantifying placental oxygenation using ultrasound-guided frequency-domain near-infrared spectroscopy (FD-NIRS)
    Ko, Tiffany
    He, Lian
    Kavuri, Venkaiah C.
    Parthasarathy, Ashwin
    Morano, Vincent C.
    Cochran, Jeffrey
    Baker, Wesley B.
    Seigal, Julia
    Yodh, Arjun G.
    Licht, Daniel J.
    Schwartz, Nadav
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (01) : S172 - S172
  • [4] Application of near-infrared spectroscopy (NIRS) in ergonomics and exercise
    Maikala, Rammohan V.
    Hargens, Alan R.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2010, 40 (02) : 123 - 124
  • [5] Role of Near-Infrared Spectroscopy (NIRS) in Intracoronary Imaging
    Pooja M. Swamy
    Mamas A. Mamas
    Aditya S. Bharadwaj
    Current Cardiovascular Imaging Reports, 2019, 12
  • [6] Differentiation of mineral wool by near-infrared spectroscopy (NIRS)
    Paul, A.
    Broszies, T.
    Ostermann, M.
    Maiwald, M.
    Vogdt, F.
    BAUINGENIEUR, 2020, 95 (12): : 463 - 472
  • [7] A review of the application of near-infrared spectroscopy (NIRS) in forestry
    Wang, Yizhi
    Xiang, Jianying
    Tang, Yu
    Chen, Wanjun
    Xu, Yuanjie
    APPLIED SPECTROSCOPY REVIEWS, 2022, 57 (04) : 300 - 317
  • [8] Role of Near-Infrared Spectroscopy (NIRS) in Intracoronary Imaging
    Swamy, Pooja M.
    Mamas, Mamas A.
    Bharadwaj, Aditya S.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (08)
  • [9] Evaluation of near-infrared spectroscopy (NIRS) under apnea
    Eichhorn, L.
    Erdfelder, F.
    Kessler, F.
    Ellerkmann, R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 40 - 41
  • [10] Near-infrared spectroscopy: indications and interpretation
    Still, Brady
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 2024, 62 (02) : 48 - 52