A hybrid transformer (HT) is implemented by augmenting the traditional low frequency transformer with a partially rated power electronic (PE) module. This paper presents a control methodology that enables the hybrid transformer to perform harmonic isolation in addition to typical load voltage regulation. The operational challenges with the hybrid transformer due to the limited power rating of the power electronic module is addressed while formulating the proposed control approach. An adaptive gain is introduced to ensure that the hybrid transformer operates within the permissible limits, regardless of the grid and load conditions. A dq-frame small-signal analysis is carried out to derive the emulated impedance by the hybrid transformer. The emulated impedance validates the operation of the hybrid transformer as a harmonic isolator, and also gives insight into physical meaning of the adaptive gain. The proposed hybrid transformer system is suitable for power delivery to sensitive clustered harmonic loads, such as data centers. The effectiveness of the proposed system is validated through simulation results.
引用
收藏
页码:4872 / 4878
页数:7
相关论文
共 50 条
  • [31] A Microcontroller Implementation of Harmonic Control Arrays Method
    Celebi, Mehmet Fatih
    Dogruel, Murat
    2017 25TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2017,
  • [32] A novel control method for wideband harmonic compensation
    Routimo, M
    Salo, A
    Tuusa, H
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 799 - 804
  • [33] DYNAMIC STIFFNESS METHOD FOR SPACE FRAMES UNDER DISTRIBUTED HARMONIC LOADS
    DUMIR, PC
    SAHA, DC
    SENGUPTA, S
    COMPUTERS & STRUCTURES, 1992, 45 (03) : 495 - 503
  • [34] A study on the noise reduction method of transformer using harmonic response analysis
    Kim, Chang-Seop
    Kim, Won-Jin
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2024, 43 (03): : 277 - 284
  • [35] Sensitive relay for power auto-transformer protection based on fifth harmonic criteria
    Htita, I. M.
    Mousa, Sabry
    Hasan, S.
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 114 - 120
  • [36] Reactive Power and Current Harmonic Control Using a Dual Hybrid Power Filter for Unbalanced Non-Linear Loads
    Limongi, Leonardo Rodrigues
    Bradaschia, Fabricio
    de Oliveira Lima, Calebe Hermann
    Cavalcanti, Marcelo Cabral
    ENERGIES, 2018, 11 (06)
  • [37] Deep learning based control of DSTATCOM for harmonic mitigation in hybrid distributed generation system with non-linear loads
    Mohammed, Mujahid Irfan
    ENERGY REPORTS, 2024, 12 : 4339 - 4351
  • [38] An Algebraic Method for Harmonic Responses based on Extended Hybrid Expansion Method
    Shen, Jingfang
    Huang, Wenlin
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON EDUCATION, MANAGEMENT, INFORMATION AND MECHANICAL ENGINEERING (EMIM 2017), 2017, 76 : 55 - 61
  • [39] An online control method of APLC for network-wide harmonic suppression considering the coupling characteristics of nonlinear loads
    Zhai, Hao
    Yi, Hao
    Zhuo, Fang
    Shi, Shuhuai
    Wang, Zhenxiong
    Zeng, Zhirong
    Zhang, Zhigang
    2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [40] Harmonic suppression in HVDC system using a modified control method for hybrid active DC filter
    Hajibeigy, Mahdi
    Farsadi, Murteza
    Nazarpour, Daryoosh
    Golahmadi, Hamid
    Hajibeigy, Meisam
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2012, 22 (03): : 294 - 307